Johnson Controls 356486-UUM-H-0609 User Manual

USER’S INFORMATION
EFFICIENCY RATING CERTIFIED
ISO 9001
Certified Quality
Management System
MANUAL
MODELS: All Residential Multi-position Gas Furnaces (33” Models)
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
INSTRUCTIONS FOR EXAMINING THE
FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
START-UP AND SHUTDOWN INSTRUCTIONS . . . . . . . . . . . . . . . . 3
HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . 3
OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TO TURN OFF THE APPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . .4
FURNACE MAINTENANCE - USER INFORMATION . . . . . . . . . . . . 4
EXTERNAL AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
How to Clean your Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
BLOWER CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
MOTOR LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SERVICE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
TROUBLESHOOTING PROBLEMS . . . . . . . . . . . . . . . . . . . . . . . . .5
FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . .5
FURNACE MAINTENANCE - DEALER/CONTRACTOR . . . . . . . . .5
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
CONTACT INFORMATION
• Go to website at www.york.com click on “about us”, then click on “contact us” and follow the instructions.
• Contact us by mail:
Johnson Controls Unitary Products
Consumer Relations
5005 York Drive
Norman, OK 73069
TABLE OF CONTENTS
We recommend that the user read all sections of this manual and keep the manual for future reference.
FIRE OR EXPLOSION HAZARD - Failure to follow safety warnings
exactly could result in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone (includ­ing cell phone) in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s phone. Fol­low the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on labels or in manuals, be alert to the potential for personal injury.
Understand and pay particular attention to the signal words DANGER,
WARNING , or CAUTION. DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in m inor or moderate injury. alert against unsafe practices and hazards involving only property dam­age.
.
.
It is also used to
1. The furnace area must be kept clear and free of combustible mate­rials, gasoline and other flammable vapors and liquids.
2. Insulating materials may be combustible. The furnace must be kept free and clear of insulating materials. The furnace area must be examined when installed in an attic or other insulated space or when insulation is added to be sure that the insulation material has been kept away from the furnace.
3. The furnace needs air for combustion in order to operate properly and safely. Do not block or obstruct air openings on the furnace, air openings to the area where the furnace is installed, or spaces around the furnace.
4. Follow the instructions exactly as shown on the OPERATING INSTRUCTION LABEL on the furnace or the “START-UP AND SHUTDOWN INSTRUCTIONS” section of this manual when light­ing the furnace or turning the furnace off.
5. Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the furnace before shutting off the electrical supply.
6. Do not use this furnace if any part has been under water. A flood­damaged furnace is extremely dangerous. Attempts to use the fur­nace can result in fire or explosion. A qualified service agency should be contacted to inspect the furnace and replace all gas controls, control system parts, electrical parts that have been wet or the furnace if deemed necessary.
7. NEVER . . .Store flammable materials of any kind near your fur­nace. Gasoline, solvents, and other volatile liquids should be stored only in approved containers outside your home. These materials vaporize easily and are extremely dangerous.
8. NEVER . . .Store cleaning materials near your furnace. Materials such as bleaches, detergents, powdered cleansers, etc., can cause corrosion of the heat exchangers.
9. NEVER . . . Use the area around your furnace as a storage area for items which could block the normal flow of air. This flow of air is required for ventilation of the various furnace components.
356486-UUM-H-0609
356486-UUM-H-0609
Vent Pipe
Pressure Switch
Silicone Tube
Rollout Safety Switch
Gas Valve
Flame Sensor
Induced Draft Assembly
Induced Draft Motor
Limit Switch
Ignitor
Manifold Pipe
Safety Door Switch
Control Board
Flue Collar
Electrical Junction Box
Blower
Transformer
Capacitor
(Not used on all models)
Power Factor Choke
(Not used on all models)
Vent Pipe
Pressure Switch
Manifold Pipe
Rollout Safety Switch
Gas Valve
Flame Sensor
Manifold Draft Assembly
Limit Switch
Ignitor
Safety Door Switch
Control Board
Electrical Junction Box
Blower
Transformer
Capacitor
Condensate Pan
Silicone Tube
(Not used on all models)
Power Factor Choke
(Not used on all models)
Pressure Sensor
Silicone Tube
Rollout Safety Switch
Gas Valve
Flame Sensor
Induced Draft Assembly
Induced Draft Motor
Limit Switch
Ignitor
Manifold Pipe
Safety Door Switch
Control Board
Flue Collar
Electrical Junction Box
Blower
Transformer
Capacitor
PSC MOTOR
Pressure Switch
Pressure Switch
Pressure Sensor
Silicone Tube
Rollout Safety Switch
Gas Valve
Flame Sensor
Induced Draft Assembly
Induced Draft Motor
Limit Switch
Ignitor
Manifold Pipe
Safety Door Switch
Control Board
Flue Collar
Electrical Junction Box
Blower
Transformer
Power Factor Choke
ECM MOTOR
(Not used on all models)
FIRE OR EXPLOSION HAZARD
This furnace is designed and approved for use with Natural Gas and (LP) Propane Gas ONLY. DO NOT BURN ANY LIQUID FUEL OR SOLID FUEL IN THIS FURNACE.
Burning any unapproved fuel will result in damage to the furnace heat exchanger, which could result in Fire, Personal Injury, and/or Property Damage.
SECTION II: INSTRUCTIONS FOR EXAMINING THE FURNACE INSTALLATION
It is the owner’s responsibility to ensure that an annual inspection of the entire heating portion of the unit is made by a qualified service agency. Examine the furnace as outlined below in steps “1 - 8” before each heating season. Use Figures 1 - 6 for visual reference.
FIGURE 1: Component Location - 80% Single & Two Stage Models FIGURE 2: Component Location - 95% Single & 96% Two Stage Models
FIGURE 3: Component Location - 80% Modulating PSC Models FIGURE 4: Component Location - 80% Modulating ECM Models
2 Johnson Controls Unitary Products
356486-UUM-H-0609
Vent Pipe
Pressure Switch
Manifold Pipe
Rollout Safety Switch
Gas Valve
Flame Sensor
Draft Inducer Assembly
Ignitor
Safety Door Switch
Control Board
Electrical Junction Box
Blower
Transformer
Capacitor
Condensate Pan
Silicone Tube
PSC MOTOR
Limit Switch (Behind gas valve)
Vent Pipe
Pressure Switch
Manifold Pipe
Rollout Safety Switch
Gas Valve
Flame Sensor
Draft Inducer Assembly
Limit Switch (Behind gas valve)
Ignitor
Safety Door Switch
Control Board
Electrical Junction Box
Blower
Transformer
Condensate Pan
Silicone Tube
ECM MOTOR
Power Factor Choke (Not used on all models)
Blue Cone Portion of Flame Should Enter Heat Exchanger Tube
FIGURE 5: Component Location - 97% Modulating PSC Models FIGURE 6: Component Location - 97% Modulating ECM Models
1. Examine the heat exchanger, vent pipe, combustion air passages, vent connectors and chimney to be sure they are clear and free of obstructions.
2. Examine the vent pipe making sure it is firmly in place, that it slopes slightly upward and is physically sound without holes and all of the connections are secure.
3. Examine the return-air duct connections to make sure they are physically sound, sealed to the furnace casing, and the ducts ter­minate outside the space containing the furnace.
4. Examine the furnace casing making sure the physical support is sound without sagging, cracks or gaps. Examine the furnace base making sure it is physically sound without cracks, gaps or sagging and has a good seal.
5. Examine the furnace casing for obvious signs of deterioration.
6. Examine the burner flames to make sure they are in good adjust­ment. Refer to the pictorial sketch shown in Figure 7 as a compar­ison to the actual flame.
FIGURE 7: Burner Flame Drawing (Upflow Configuration Shown)
7. Examine and replace external air filters as needed to make sure they are not blocked, and proper airflow is provided to the furnace.
8. Examine any installed accessories or system components such as evaporator coils to insure proper operation, drainage of conden­sate, and that there is no water leakage or damage to the furnace or any components.
Johnson Controls Unitary Products 3
SECTION III: START-UP AND SHUTDOWN INSTRUCTIONS
Read the Instructions Below Before Trying to Start the Furnace!
If you do not follow these instructions exactly, a fire or explo­sion may result causing property damage, personal injury, and/or loss of life.
HOW YOUR GAS FURNACE WORKS
Your furnace is a very easy appliance to take for granted. Season after season, it sits there in your home, keeping you warm and comfortable. For this reason, you may never have given much thought to the way your furnace operates. In order to get the safest and most efficient oper­ation from your furnace, you should understand how your furnace does its job.
When you set your thermostat to provide more heat in your home, you are starting the heating cycle of the furnace. First, the inducer motor starts to purge the heat exchanger of any remaining gases. Next, the hot surface ignitor glows and after a warm-up period the gas valve opens and ignition occurs. A short time later, the blower starts and dis­tributes the warm air throughout the home. When the temperature set­ting on your thermostat is reached, the gas valve closes, the main burners are turned off, and the blower continues to run until the remain­ing warm air in the system is distributed. When the blower stops, the heating cycle has ended.
1. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.
2. BEFORE OPERATING; smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
3. Use only your hand to push the gas control switch to the ON posi­tion. Never use tools. If the switch will not operate by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
4. Do not use this appliance if any part has been under water. Imme­diately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.
356486-UUM-H-0609
External Manual Shutoff Valve
To Gas Supply
To Gas Supply
Grounded Joint Union
may be Installed
Inside or Outside Unit.
Drip Leg
Inlet
Wrench Boss
Inlet Pressure Port
ON
OFF
On/Off Switch (Shown in ON position)
Main Regulator Adjustment
Outlet
Outlet Pressure Port
Vent Port
INLET
WRENCH BOSS
INLET PRESSURE PORT
ON OFF SWITCH
LOW STAGE REGULATOR ADJUSTMENT
OUTLET
OUTLET PRESSURE PORT
VENT PORT
HIGH STAGE REGULATOR ADJUSTMENT
Inlet Pressure Tap
Outlet Pressure Tap
On/Off Knob
Main Regulator Adjustment
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above for your protection.
2. Set the thermostat to the lowest setting in the heat mode.
3. Turn off all electric power to the appliance.
4. Remove furnace burner access panel/door.
5. Move gas control switch to the OFF position. Do not force. See Figures 9-11.
6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to next step.
7. Move gas control switch to the ON position. Do not force. See Fig­ures 9-11.
8. Replace furnace burner access panel/door.
9. Turn on all electric power to the appliance.
10. Set thermostat to the desired setting. Burner will lig ht, which may take 30-60 seconds.
11. After three (3) trials for ignition, if the appliance will not operate fol­low the instructions, “TO TURN OFF THE APPLIANCE” and call your service technician or gas supplier.
TO TURN OFF THE APPLIANCE
1. Set the thermostat to lowest setting in heating mode.
2. Turn off all electric power to the appliance if service is to be per­formed.
3. Remove furnace burner access panel/door.
4. Move gas control switch to the “OFF” position. See Figures 9-11.
5. Replace furnace burner access panel/door.
FIGURE 10: Two-Stage Gas Valve
FIGURE 11: Modulating Gas Valve
SECTION IV: FURNACE MAINTENANCE -
Should overheating occur, or the gas valve fail to shut off, turn the external manual gas valve in the gas supply line to the fur­nace to the “off” position and let the furnace cool off before shutting off the electrical power supply.
FIGURE 8: Gas Piping
FIGURE 9: Single Stage Gas Valve
4 Johnson Controls Unitary Products
USER INFORMATION
Before proceeding, be sure the area is well ventilated. Turn the thermostat OFF. If the blower is running, wait until it stops auto­matically. Turn OFF the gas and electrical power supplies to the furnace. Check all metal parts and surfaces to be sure they have cooled to room temperature before you begin.
EXTERNAL AIR FILTERS
Filters used with this furnace must be installed external to the furnace casing. DO NOT attempt to install filters inside the furnace cabinet.
Some installations may have the air filter in a rack attached to the cas­ing of the furnace or placed in the return air duct. If the filter location or replacement process is not obvious, contact your installer or service technician for assistance.
Every time the external air filters are changed the following items should be visually inspected:
• Check combustion air and vent pipe for blockage or leakage.
• Check all components to be sure they are in good condition and that there are no obvious signs of deterioration.
• Check the drain lines to make sure there are no cracks or leaks.
• Check for dirt or lint on any surfaces or on components. Do not try to clean any of the surfaces or components. Cleaning of the fur­nace and its components must be done by a qualified service pro­fessional.
356486-UUM-H-0609
If during the inspection of your furnace, you find any of the following conditions:
• Excessive amounts of dust and lint on components.
• Damaged or deteriorated components or surfaces.
• Leaks or blockage in the vent pipe passages.
• Water on any surface inside or outside of the furnace.
Do not operate the furnace, call a certified dealer or servicing contractor to check or clean your furnace, or for more information if you have questions about the operation of your furnace.
If all components appear to be in good operating condition, replace the furnace access panels/doors. Turn ON the gas and electrical power supplies to the furnace, and set thermostat to the desired temperature.
How to Clean your Filter
High-velocity filters may be cleaned with a vacuum cleaner or washed with a garden hose. Be sure to shake off excess water and allow filter to completely dry before re-installing the filter.
Replace throw away filter(s) with the same size new filter(s). Throw away filter(s) may be replaced with cleanable filter(s) at this time.
BLOWER CARE
Even with good filters properly in place, blower wheels and motors will become dust laden after months of operation. The entire blower assem­bly should be inspected annually. This service must be performed by a qualified service agency.
NOTE: The spring-loaded safety cut-off switch, mounted at the blower deck will automatically cut off the electrical power supply to the furnace when the furnace blower access panel/door is removed. As a safety precaution, all electrical power and the gas supply to the furnace should be turned off before servicing.
Make sure you DO NOT move the clip on weight on the indoor fan wheel when cleaning the wheel. This weight is used to balance the wheel. Moving the weight will cause the fan wheel to vibrate.
MOTOR LUBRICATION
The motors in these furnaces are permanently lubricated, and do not require periodic oiling.
SECTION V: SERVICE INFORMATION
TROUBLESHOOTING PROBLEMS
If your furnace is not operating correctly, the following visual checks should be made before contacting your local contractor, dealer, or ser­vice provider.
1. Check that electrical power to the furnace is turned on.
2. Check that the manual gas shut-off valve in the gas piping supply is turned to the ON position. Refer to Figure 9.
3. Check that the ON/OFF switch on the gas valve is turned to the ON position. Refer to Figures 9, 7 or 8.
4. Check that the furnace blower access panel/door is correctly posi­tioned. The electrical power supply will be cut off if this door is removed.
FURNACE CONTROL DIAGNOSTICS
The furnace has built-in, self-diagnostic capability. If a system problem occurs, a blinking LED shows a fault code. The LED can flash red, green or amber to indicate various conditions. It is located behind a clear view port in the blower compartment door.
The control continuously monitors its own operation and the operation of the system. If a failure occurs, the LED will indicate the failure code. If the failure is internal to the control, the light will stay on continuously. In this case, the entire control should be replaced, as the control is not field repairable.
Flash sequence codes 1 through 10 are as follows: LED will turn ON for 1/4 second and OFF for 1/4 second. This pattern will be repeated the number of times equal to the code. For example, six ON flashes equals a number 6 fault code. All flash code sequences are broken by a 2 sec­ond OFF period.
SLOW GREEN FLASH: Normal operation. DOUBLE AMBER FLASH: Normal heating operation - Modulating Fur-
nace Models Only
SLOW AMBER FLASH: Normal operation with call for heat. RAPID RED FLASHES: There is a problem with the operation of this
furnace. Contact your local dealer, contractor or service provider.
FURNACE MAINTENANCE - DEALER/CONTRACTOR
The furnace should be cleaned and adjusted by a certified dealer or qualified service contractor once a year or before the start of every heating season. The following items must be cleaned and serviced or replaced if there are signs of deterioration.
1. The vent terminal.
2. The furnace vent and combustion air intake passageways. Should it be necessary to service the vent/air intake system, the manufac­turer recommends this service be conducted by a qualified service agency. The operation of this appliance requires the reassembly and resealing of the vent/air intake system.
3. The furnace burners, ignitor and flame sensor.
4. The condensate collection and disposal system. If any disassem­bly of components containing flue or vent gases is required, a qualified service agency must perform the service.
5. Heat exchanger assembly.
6. Induced draft motor assembly.
REPLACEMENT PARTS LIST
All components, assemblies, accessories, and replacement parts for this furnace are available through qualified service agencies. It is not recommended that the user purchase, install, or replace any compo­nents of this furnace. Contact your local contactor, dealer, or service provider for additional information.
WIRING DIAGRAM
The unit wiring diagram may be found on the inside of one of the access panels on the furnace. It is intended for reference only. If service is required, contact your local contactor, dealer, or service provider.
Johnson Controls Unitary Products 5
Limited Warranty
Johnson Controls Unitary Products (her einafter “Company”) warran ts this product to be free from defects in factor y workmanship and ma terial under normal use and service and will, at its option, repair or replace any parts, without charge, subject to the exclusions below, that prove to have such defects according to the terms outlined on this warranty. This warranty covers only the equipment described by the Product Model Number and Serial Number on the equipment or listed on the Warranty Registration Card and a pplies only to products installed in the United States or Canada.
FOR WARRANTY SERVICE OR REPAIR:
Contact the installer or a Company dealer. You may find the installer’s name on this page or on the equipment. You can also find a Company dealer online at www.yorkupg.com. For help finding a servici ng dealer, contact: Johnson Controls Unitary Products, Consumer Re lations, 5005 York Drive, Norman, OK
73069. Or, by phone 877-874-7378. All warranty servic e or repair will be performed during regular business hours, Monday through Friday 9:00am-5:00pm.
Product Model No.__________________________________ Unit Serial No._____________________________________
FOR PRODUCT REGISTRATION: For your benefit and protection, return the Warranty Registration Card to Company promptly after installation. This will ini­tiate the warranty period and allow us to contact you, should it become necessary. For this warranty to apply, the product must be installed according to Com­pany recommendations and specificat ions, an d in accord ance wit h all loc al, state, a nd nation al codes; a nd the pr oduct must not be r emoved f rom its place of original installation. The w arranty period for re pair or rep lacemen t parts provided hereun der sha ll not e xtend b eyond the warra n ty peri od stated below. In the absence of a recorded Warranty Registration Card, the warrant y period will beg in upon product sh ipment from Company. If you are unaware of the date th e warranty became effective, contact Com pany at 877 -874-73 78 or vi sit www.upgproductregis tration .com. You can register your product online at www.upgpro­ductregistration.com or by returning the Warranty Registration Card on the back page of this packet.
HEAT EXCHANGER WARRANTY ADDITIONAL TERMS: Company warrants the heat exchangers (primary an d/ or secondary, if applicable) in this product to be free from defects in factory workma nship and mat erial un der norma l use and ser vice an d will at its opt ion, repair or fu rnish a replac ement hea t exc hange r, either new or reconditioned that meets the intende d fit, use and funct ion of the origin al heat exchanger. Alternatively, Company may, at its option, extend a replacement allowance to b e app lied t oward t he pu rchas e of a new fu rnac e market ed by Company. The exact amount of the a llowan ce will be det ermi ned at the discretion of Company, based upon current market conditions, but in no case shall this allowance exceed thirty (30) percent of the original consumer pur­chase price of the furnace , excluding such items as ductw ork, wiring, piping, and installation costs. Company shall have no responsibility hereunder for instal­lation, shipping, handling or other charges except as specifically provided herein.
The warranty period in years, depending on the part and the claimant, is as sh own in the chart below.
FURNACE TYPE
GG8S,GGLS TM8X,TMLX,TM8T,TMLT,TM8V,TMLV,TG8S,TGLS GG9S TM9V,TM9T,TM9X,TG9S TP9C,TP8C,TPLC,TM9M,TM8M,TMLM,YP9C,YP8C,YPLC,YM9M,YM8M,YMLM CP9C,CP8C,CPLC,CM9M,CM8M,CMLM,LP9C,LP8C,LPLC,LM9M,LM8M,LMLM
T o qual ify for t he extended 10- year p art s war ranty, the unit must be registered online at www.upgproductregistration.com within 90 days of installa tion for repl acement or 90 days of closing for new home construction. In some states, registration is not required, but proof of installation may is required to qualify for the 10-year parts warranty. Guar dian Brand products have a 5-year compressor and 5-year parts warranty and are not eligible for the 10-year parts warranty.
Company strongly recommends regular periodic preventative maintenance on t his equipment. The person most familiar with the equipment in your HVAC sys­tem is a Company dealer. The Company dealer can ensure your maintenance program me ets the conditions of the "Company Warranty", maximize the effi­ciency of the equipment, and service your unit within the mandated guidelines with regard to unlawful discharge of refrigerants into the atmosphere.
EXCLUSIONS:
This warranty does not cover any:
1. Shipping, labor, or material charges or damages resulting fro m transportation, installation, or servicing.
2. Damages re sulting from acci dent, abuse, fire, flood, alterati on, or acts of God (tamperi ng, altering, def acing or removing t he produc t serial number wi ll serve to void this warranty).
3. Damages resulting from use of the product in a corrosive atmosphere.
4. Damages resulting from inadequacy or interruption of electrical service or fuel supply, improper voltage conditions, blown fuses, or other like damages.
5. Cleaning or replacement of filters or damages resulting from operation with inadequate supply of air or water.
6. Damages resulting from failure to properly and regularly clean air and/or water side of condenser and evaporator.
7. Damages resulting from: (I) freezing of condenser water or condensate; (II) inadequate or interrupted water supply; (III) use of corrosive water; (IV) fouling or restriction of the water circuit by foreign material or li ke causes.
8. Damages resulting from use of components or accessories not ap pr ov ed by Company (vent dampers, etc.).
9. Increase in fuel or electric cost.
This warranty is in lieu of all other warr anties, e xpres se d o r implied, including the implied warranti es of mer ch an tability and fit nes s f or a particula r purpose.
Some states do not allow the disclaimer of implied wa rranty, so that the above disclaimer may not apply to you. Some states only allow a partial limitation on implied warranties to limit the duration of implied warranties to the duration of the express warranty. In such states, the duration of implied warranties is hereby expres sly limi ted to the dura tion of t he expr ess warran ty on t he face hereof . Some states do no t allow limitations on how long an implied warranty lasts, so the abo ve limitation may not apply to you.
In no event, whether as a result of breach of warranty or contract, tort (including negligence), strict liability, or otherwise, shall Company be liable for special, incidental, or conseq uential damages, including but not limited to loss of use of the equipment or associated equipment, lost revenues or profits, cost of substitute equipment or cost of fuel or electricity. The above limitations shall inure to the benefit of Co mpany’s suppliers and subcontractors. The above limitation on consequential damages shall not apply to injuries to persons in the case of consumer goods.
Company does not assume, or authorize any other person to ass ume for Company, any other liability for the sale of th is produ ct. Some states do not allow the exclusion or limitation of incidental or consequently damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.
Installation Date_________________________________________ Installing Dealer____________ ____ _________________________
Residential Applications
Original Owner
Lifetime 20 10 5
Lifetime 20 10 5 or 10†
HEAT EXCHANGER
Subsequent
20 N/A 10 5 20 N/A 10 5 or 10†
Owner
Non-Residential
Applications
PARTS
Subject to change without notice. Printed in U.S.A. 356486-UUM-H-0609 Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 356486-UUM-G-0409
Johnson Controls Unitar y Products
5005 York Drive
Norman, OK 73069