Johnson Controls 356486-UUM-H-0609 User Manual

USER’S INFORMATION
EFFICIENCY RATING CERTIFIED
ISO 9001
Certified Quality
Management System
MANUAL
MODELS: All Residential Multi-position Gas Furnaces (33” Models)
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
INSTRUCTIONS FOR EXAMINING THE
FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
START-UP AND SHUTDOWN INSTRUCTIONS . . . . . . . . . . . . . . . . 3
HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . 3
OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TO TURN OFF THE APPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . .4
FURNACE MAINTENANCE - USER INFORMATION . . . . . . . . . . . . 4
EXTERNAL AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
How to Clean your Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
BLOWER CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
MOTOR LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SERVICE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
TROUBLESHOOTING PROBLEMS . . . . . . . . . . . . . . . . . . . . . . . . .5
FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . .5
FURNACE MAINTENANCE - DEALER/CONTRACTOR . . . . . . . . .5
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
CONTACT INFORMATION
• Go to website at www.york.com click on “about us”, then click on “contact us” and follow the instructions.
• Contact us by mail:
Johnson Controls Unitary Products
Consumer Relations
5005 York Drive
Norman, OK 73069
TABLE OF CONTENTS
We recommend that the user read all sections of this manual and keep the manual for future reference.
FIRE OR EXPLOSION HAZARD - Failure to follow safety warnings
exactly could result in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone (includ­ing cell phone) in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s phone. Fol­low the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on labels or in manuals, be alert to the potential for personal injury.
Understand and pay particular attention to the signal words DANGER,
WARNING , or CAUTION. DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in m inor or moderate injury. alert against unsafe practices and hazards involving only property dam­age.
.
.
It is also used to
1. The furnace area must be kept clear and free of combustible mate­rials, gasoline and other flammable vapors and liquids.
2. Insulating materials may be combustible. The furnace must be kept free and clear of insulating materials. The furnace area must be examined when installed in an attic or other insulated space or when insulation is added to be sure that the insulation material has been kept away from the furnace.
3. The furnace needs air for combustion in order to operate properly and safely. Do not block or obstruct air openings on the furnace, air openings to the area where the furnace is installed, or spaces around the furnace.
4. Follow the instructions exactly as shown on the OPERATING INSTRUCTION LABEL on the furnace or the “START-UP AND SHUTDOWN INSTRUCTIONS” section of this manual when light­ing the furnace or turning the furnace off.
5. Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the furnace before shutting off the electrical supply.
6. Do not use this furnace if any part has been under water. A flood­damaged furnace is extremely dangerous. Attempts to use the fur­nace can result in fire or explosion. A qualified service agency should be contacted to inspect the furnace and replace all gas controls, control system parts, electrical parts that have been wet or the furnace if deemed necessary.
7. NEVER . . .Store flammable materials of any kind near your fur­nace. Gasoline, solvents, and other volatile liquids should be stored only in approved containers outside your home. These materials vaporize easily and are extremely dangerous.
8. NEVER . . .Store cleaning materials near your furnace. Materials such as bleaches, detergents, powdered cleansers, etc., can cause corrosion of the heat exchangers.
9. NEVER . . . Use the area around your furnace as a storage area for items which could block the normal flow of air. This flow of air is required for ventilation of the various furnace components.
356486-UUM-H-0609
356486-UUM-H-0609
Vent Pipe
Pressure Switch
Silicone Tube
Rollout Safety Switch
Gas Valve
Flame Sensor
Induced Draft Assembly
Induced Draft Motor
Limit Switch
Ignitor
Manifold Pipe
Safety Door Switch
Control Board
Flue Collar
Electrical Junction Box
Blower
Transformer
Capacitor
(Not used on all models)
Power Factor Choke
(Not used on all models)
Vent Pipe
Pressure Switch
Manifold Pipe
Rollout Safety Switch
Gas Valve
Flame Sensor
Manifold Draft Assembly
Limit Switch
Ignitor
Safety Door Switch
Control Board
Electrical Junction Box
Blower
Transformer
Capacitor
Condensate Pan
Silicone Tube
(Not used on all models)
Power Factor Choke
(Not used on all models)
Pressure Sensor
Silicone Tube
Rollout Safety Switch
Gas Valve
Flame Sensor
Induced Draft Assembly
Induced Draft Motor
Limit Switch
Ignitor
Manifold Pipe
Safety Door Switch
Control Board
Flue Collar
Electrical Junction Box
Blower
Transformer
Capacitor
PSC MOTOR
Pressure Switch
Pressure Switch
Pressure Sensor
Silicone Tube
Rollout Safety Switch
Gas Valve
Flame Sensor
Induced Draft Assembly
Induced Draft Motor
Limit Switch
Ignitor
Manifold Pipe
Safety Door Switch
Control Board
Flue Collar
Electrical Junction Box
Blower
Transformer
Power Factor Choke
ECM MOTOR
(Not used on all models)
FIRE OR EXPLOSION HAZARD
This furnace is designed and approved for use with Natural Gas and (LP) Propane Gas ONLY. DO NOT BURN ANY LIQUID FUEL OR SOLID FUEL IN THIS FURNACE.
Burning any unapproved fuel will result in damage to the furnace heat exchanger, which could result in Fire, Personal Injury, and/or Property Damage.
SECTION II: INSTRUCTIONS FOR EXAMINING THE FURNACE INSTALLATION
It is the owner’s responsibility to ensure that an annual inspection of the entire heating portion of the unit is made by a qualified service agency. Examine the furnace as outlined below in steps “1 - 8” before each heating season. Use Figures 1 - 6 for visual reference.
FIGURE 1: Component Location - 80% Single & Two Stage Models FIGURE 2: Component Location - 95% Single & 96% Two Stage Models
FIGURE 3: Component Location - 80% Modulating PSC Models FIGURE 4: Component Location - 80% Modulating ECM Models
2 Johnson Controls Unitary Products