Johnson J-5800 Service Manual

Page 1
J-5800 MASSAGE CHAIR
SERVICE MANUAL
2014/03/17 EV 2
Page 2
Johnson Health Tech. Co., Ltd.
Summary
2-1. Motor testing (P1) 2-2. Sensor testing (P2) 2-3. Current testing (P3)
2-4. Air pressure testing (P4) 2-5. Software version detection model (PU) 3. Error codes
3-1. OF, 90 3-2. A0 3-3. A1 3-4. A2, A3, B0, B1
3-5. B2, B3, C0, C1 3-6. D0 3-7. E0 3-8. E1, E2 3-9.E3
4.Common troubleshooting
4.1 Fail to start 4.2 Pushrod motor 4.3 Single air bag
4.4 All air bags 4.5 All air bags 4.6 Machine core
5. Appendices
5.1 Replace the machine core 5.2 Software update 5.3 Adjust machine core motor current
5.4 Complete machine breakdown drawing 5.5 Machine core breakdown drawing
5.6 Lower control panel breakdown drawing
Thank you! (Contact us)
Page 3
Johnson Health Tech. Co., Ltd.
Foreword
Precautions during repairs and faults:
a. When disassembling, unplugging connectors and replacing parts, make sure to unplug or turn off the power.
b. As semiconductors (IC, etc.) are prone to being damaged by static electricity, please use human body electrostatic discharge ground wire if it is required to directly contact the baseplate when performing operations, or touch the ground wire (ground wires of fridges, washing machines, etc.) with bare hands to discharge the static electricity of the human body before carrying out operations.
c. The circuit baseplate mixes high voltage (AC110V, AC220V) and low voltage (12V, 5V), which may cause electric shock accident; so please do not have direct contact without preparations.
Page 4
Johnson Health Tech. Co., Ltd.
1.Product Specifications
Page 5
Johnson Health Tech. Co., Ltd.
1.Product Specifications
Page 6
Johnson Health Tech. Co., Ltd.
1. When the power is on and manual controller is not yet actuated, press
MANUAL
MANUAL and
LEG STRETCH
LEG STRETCH on the
manual controller at the same time for 5 seconds and the controller will display “ - - ”
2. Then press
REPEAT
REPEAT key to enter engineering mode
3. In the engineering mode,“ P0 ” will be displayed
2. Engineering mode introduction:
In the engineering mode,“ P0 ” will be displayed
Page 7
Johnson Health Tech. Co., Ltd.
4 . Use
UP
UP and
DOWN
DOWN to select 8 modes,
including P0~P4+P7+P8+PU
5 . In mode selection state, press
WIDE
WIDE
to enter the mode to operate the massage chair
6 . After mode selection, use
UP
UP
and
DOWN
DOWN
again to select the element to
be controlled, such as A0~A5
2. Engineering mode introduction:
Page 8
Johnson Health Tech. Co., Ltd.
7 . After entering the mode, press
STOP
STOP key to return to the
previous layer of menu; this key has the same function as the ESC key of the computer keyboard
8 . After element selection, use AIR STRENGTH to adjust the
element speed, and the intensity will be displayed as the air pressure strength, with one to three representing from weak to strong
2. Engineering mode introduction:
Page 9
Johnson Health Tech. Co., Ltd.
Key Operation
Emergency stop Return to the previous layer of menu
Up Forward mode selection
down
Reverse mode selection
Wide
Select ok and the air bag moves or motor rotates forward
Narrow
Motor rotates reverse
Power switch Exit engineering mode
Air bag strength (panel) Speed selection (3: high, 2: medium, 1: low)
LCD
LCD Operation
Time window
Display selected element number and corresponding current or position
Air pressure strength Speed display (3: high, 2: medium, 1:low)
2.
Engineering mode introduction:
Engineering mode introduction:
Page 10
Johnson Health Tech. Co., Ltd.
— —
P0 : Hand controllertestingmode
P1 : Motor testing mode
P2 : Sensor testing mode
P3 : Current testing mode
P4 : Air bag testing mode
P7 : Automatic testing mode
P8 : Life testing mode
PU : Software version check
2.
Engineering mode introduction:
Engineering mode introduction:
P0 : Manual controller testing mode
P1 : Motor testing mode
PU : Software version check
P7 : Automatic testing mode
P8 : Life testing mode
P4 : Air bag testing mode
P3 : Current testing mode
P2 : Sensor testing mode
Page 11
Johnson Health Tech. Co., Ltd.
P1 Motor testing mode
A0 : Up and down movement of machine core
A5 : Machine core pounding motion
A4 : Kneading-Forward and reverse rotation of machine core
A3 : Front and back movement of machine core
A2 : Up and down movement of chair back
A1 : Up and down movement of foot machine
Motor test mode is mainly used to test if each motor works normally and to adjust
chair angle when replacing elements
2-1. Engineering mode: P1
A6 : Forward and back movement of foot machine
Page 12
Johnson Health Tech. Co., Ltd.
P2 sensor testing
C0 : Up and down movement of machine core
C4 : Kneading-Forward and reverse rotation of machine core
C3 : Front and back movement of machine core
C2 : Up and down movement of chair back
C1 : Up and down movement of foot machine
Sensor testing is mainly used to test and indicate limits and counts. When operating motor in this mode, LCD time window will display the digit returned by the sensor. When the digit exceeds 100, the carrying digit will display “massage intensity” (100~500) and “motion menu”.
LCD sensing position display window will indicate whether the limit switch is triggered
2-2. Engineering mode: P2
C5 : Forward and back movement of foot machine
Page 13
Johnson Health Tech. Co., Ltd.
Upper limit is
triggered
Tens and ones
of returned
values
Hundreds of
returned values
Current speed
of motor
motion
The left figure shows that the upper limit is reached when the selected machine core (C1) rises
When the upper limit light is, it means that the machine core is unable to move upward; when the lower limit light is on, the machine core is unable to move downward
The “Massage Strength” lamp signal 1 of massage intensity represents 100, 2 represents 200, and so on
“KNEAD” lamp represents 600,”KAT”
lamp represents 700.
We can tell by the above rules that the returned value on the left figure is time window (40) + motion menu lamp signal (700) =740
2-2. Engineering mode: P2
Page 14
Johnson Health Tech. Co., Ltd.
P3 current testing
D0 : Up and down migration current of machine core
D4 : Kneading-Forward and reverse rotation current of
machine core
D3 : Front and back migration current of machine core
D2 : Up and down migration current of chair back
Current testing is mainly used to test if the motor current is too high
When the returned number exceeds 100, the carrying digit will display “massage intensity” (100~500)
D3 is a major test item; if the intensity is set to medium (air bag strength 2) and machine core forward value is greater than 50, it is likely to generate error code D0 because the current is too high to lower the sensitivity of induction mechanism
2-3. Engineering mode: P3
Page 15
Johnson Health Tech. Co., Ltd.
P4 air bag testing
1 : shoulder air bag
5 : right arm air bag
3 : right waist air bag
Air bag testing is mainly used to test if the air bag works normally, the inflation rate is normal, there is leakage, etc.
It can also distinguish the position of the air bag to be tested via the pattern on the manual controller.
6 : left hip air bag
7 : right hip air bag
8 : instep air bag
9 : thigh air bag
10 : calf air bag
11 : air bag below the leg
2 : left waist air bag
12 : air bag above the leg
4 : left arm air bag
2-4. Engineering mode: P4
Page 16
Johnson Health Tech. Co., Ltd.
Shoulder
Waist
Arm
Hip
Thigh
Upper leg
Calf
Lower leg
Instep
2-4. Engineering mode: P4
Page 17
Johnson Health Tech. Co., Ltd.
PU software version
U0 : manual controller software
version
U1 : lower control panel
software version
Software version check mode is generally used to confirm current version of massage chair and
confirm again if the update is successful after updating software
a. Press “up” or “down” key to make the time window display “PU” to enter software version check
function
b. Press “ok” function, and the time window displays “U0” to enter manual controller software
version check function
c. Press “air pressure strength” key, and the time window displays in a jumping loop of “v1”-“04”-
“v1”-“04”...... indicating that the manual controller software version is v104
d. Press “up” or “down” key to make the time window display “U1” to enter lower control panel
software version check function
e. Press “air pressure strength” key, and the time window displays in a jumping loop of “v1”-“05”-
“v1”-“05”...... indicating that the lower control panel software version is v105
f. Then, the software version is 104105
2-5. Engineering mode: PU
Page 18
Johnson Health Tech. Co., Ltd.
The error codes will appear on the machine’s manual controller and the machine will stop
Maintenance personnel can judge the fault conditions and anticipate maintenance materials
based on the error code reported by the customer
Error Code
3. Error codes
Page 19
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly Countermeasures
0F
Inconsistency
between manual
controller model
and master control
panel model
1. Inconsistency between manual controller model and lower control panel
2. Inconsistency of software versions
1. Confirm manual controller model
2. Replace with correct model software and then confirm if the machine is normal
3. Replace the lower panel and then confirm if the machine is normal
4. Ask for assistance of original factory
90
Communication
error
Communication timeout between manual controller and lower control panel
1. Confirm if connection between manual controller and lower control panel is normal
2. Update software and then confirm if the machine is normal
3. Replace the manual controller then confirm if the machine is normal
4. Replace the lower panel and then confirm if the machine is normal
5. Ask for assistance of original factory
3-1. Error code (0F, 90)
Page 20
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly Countermeasures
A0
Kneading seized
After the software gives an instruction, the kneading sensor of machine core does not return signal
1. Check if the connecting line contacts poorly
2. Check if the sensor works normally and the sensor is centered
Kneading sensor
3-2. Error code (A0)
Page 21
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly Countermeasures
A1
Up and down
seized
After the software gives an instruction, the up and down sensor of machine core does not return signal
1. Check if the connecting line contacts poorly
2. Check if the sensor works normally and code plate is centered
Upper and
lower position
sensor
3-3. Error code (A1)
Lower limit
sensor
Upper limit
sensor
Page 22
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly Countermeasures
A2
Chair back seized
Count of chair back pushrod
does not return signal
1. Check if the chair back structure is seized
2. Check if the chair back pushrod signal line contacts normally
3. Update software, and then confirm if the machine is normal
4. Replace the chair back pushrod, and then confirm if the machine is normal
5. Replace lower panel
A3
Safety switch
triggered
When the machine core
moves up and down, safety
switch is triggered
1. Except in Japan, this anomaly code is shielded in
the software; while only keeping hardware structure, updating software can eliminate the error
2. Check if the safety switch connecting line contacts
poorly
3. Check if there is any foreign matter in upper and lower
rails resulting seizure
4. Replace machine core
B0
Kneading overload
Kneading motor current is
too high
1.Check if the machine core structure is seized
2. Replace machine core
B1
Pounding overload
Pounding motor current is
too high
1. Check if the machine core structure is seized
2. Replace machine core
3-4. Error code (A2, A3, B0, B1)
Page 23
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly Countermeasures
B2
Front and back
overload
Front and back motor
current is too high
1. Check if the machine core structure is seized
2. Replace machine core
B3
Up and down
overload
Up and down motor
current is too high
1. Check if the machine core structure is seized
2. Replace machine core
C0
Abnormal
heating
Abnormal heater band
Please refer to warming function anomaly in
troubleshooting (4-6)
C1
Abnormal
thermistor
Abnormal thermistor
Please refer to warming function anomaly in
troubleshooting (4-6)
3-5. Error code (B2, B3, C0, C1)
Page 24
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly Countermeasures
D0
Empty
Incorrect sitting posture results in failure to correctly detect when detecting position
During body type detection, ask users to place their backs to the massaging balls as closely as possible
Lighter weight of users
During body type detection, ask users to place their backs to the massaging balls as closely as possible. When the massaging balls move forward for detecting, push backward as strongly as possible
Aged mechanical structures of the front and back motors of the machine core. When they move, the current rises, lowering detection function. When the user’s weight is light, it may misjudge that it is empty
1. Slightly loosen the motor set screws. Refer to 5-3 Adjust machine core’s
advance and retreat current
for procedure
2. Replace machine core (Please refer to 5-1 )
3-6. Error code (D0)
Page 25
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly Countermeasures
E0
Abnormal front
and back count
After the software gives an instruction, the front and back sensor of machine core does not return signal
1.Check if the connecting line contacts poorly
2.Check if the sensor works normally and code plate is centered
3. Replace machine core
Advance and retreat
sensor
3-7. Error code (E0)
Page 26
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly
Countermeasures
E1
Chair back count
anomaly
After the software gives an instruction, chair back pushrod does not return signal
1. Check if the connecting line contacts poorly
2. It may be interference with chair back structure. Please confirm if there is interference
3. Use spare parts to connect the main board to confirm if chair back pushrod is damaged
4. Replace main board
E2
Foot machine count
anomaly
After the software gives an instruction, foot machine pushrod does not return signal
1. Check if the connecting line contacts poorly
2. It may be interference with foot machine structure. Please confirm if there is interference
3. Use spare parts to connect the main board to confirm if foot machine pushrod is damaged
4. Replace main board
Chair back
pushrod
Foot machine
pushrod
3-8. Error code (E1, E2)
Page 27
Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description Cause of anomaly
Countermeasures
E3
Extend foot machine
count anomaly
After the software gives an instruction, extend foot machine pushrod does not return signal
1. Check if the connecting line contacts poorly
2. It may be interference with chair back structure. Please confirm if there is interference
3. Use spare parts to connect the main board to confirm if extend foot machine pushrod is damaged
4. Replace main board
Plug of extend foot
machine pushrod
3-8. Error code (E3)
Page 28
Johnson Health Tech. Co., Ltd.
Precautions during repairs and faults:
a. When disassembling, unplugging connectors and replacing parts, make
sure to unplug or turn off the power.
b. As semiconductors (IC, etc.) are prone to being damaged by static electricity, please use human body electrostatic discharge ground wire if it is required to directly contact the baseplate when performing operations, or touch the ground wire (ground wires of fridges, washing machines, etc.) with bare hands to discharge the static electricity of the human body before carrying out operations.
c. The circuit baseplate mixes high voltage (AC110V, AC220V) and low
voltage (12V, 5V), which may cause electric shock accident; so please do not have direct contact without preparations.
When measuring with an electric meter, basic electricity knowledge is required to avoid short circuits or personal dangers.
4.
Common troubleshooting
Common troubleshooting
Page 29
Johnson Health Tech. Co., Ltd.
Treatment:
When the machine fails to start, confirm if the protector is tripped
After reset, the power led turns onit may be motor overload, keep on observing
After reset, the power led turns on and then off immediatelythe circuit system may be short
circuited and requires attention. It is recommended to ask the personnel with electronic background to check and repair. There may be broken covered wires, short circuits or breakdown of electronic devices
4-1.
Fail to start
Fail to start
First, turn on the
power supply
Press the protector to reset
its status
Page 30
Johnson Health Tech. Co., Ltd.
b. Confirm if the power supply and EMC filter board are normal. Measure if AC110V (AC220V
in mainland China) power supply of output end of EMC board is normal
Possible cause: EMC board fuse damage, EMC board damage or poor contact of
connecting line
4-1.
Fail to start
Fail to start
Turn off the
power supply
Remove four set screws (red arrow),
Remove power supply cover (blue arrow)
Page 31
Johnson Health Tech. Co., Ltd.
The probe is placed on the power supply
input end
Switch to AC,
and turn on the
power supply to
confirm voltage
Test if the output
end voltage
conforms to the
input end
After the power is
off, measure if the
fuse is damaged
The main purpose is to measure if the input end voltage has output voltage (AC110V or AC220V) after passing through the filter; if there is no voltage, check if the fuse is burned (The power must
be off when measuring the fuse)
When the fuse is not burned, and there is still no output voltage, replace the filter
4-1.
Fail to start
Fail to start
Fuse
specificatio
n
Page 32
Johnson Health Tech. Co., Ltd.
c. Confirm if the transformer power supply is normal. Measure transformer output end
voltage: no load AC24-28V, AC12-15V, AC15-18V
Possible cause: the fuse inside the transformer is damaged; replace the transformer.
AC12V AC15V AC24V AC24V
4-1.
Fail to start
Fail to start
Transformer body
Voltage output plug
Page 33
Johnson Health Tech. Co., Ltd.
d. Record the software for the master control panel and manual controller
again and observe if the indicator light of the master control flashes normally.
Please refer to 5-2 Software Update
e. Change to the spare manual controller for operation. If it operates
normally, replace the manual controller; if not so, replace the master control panel
4-1.
Fail to start
Fail to start
Page 34
Johnson Health Tech. Co., Ltd.
Treatment:
Unplug the power line of the electric pushrod motor which does not work, and replace with spare pushrod motor (or replace with the electric pushrod which works normally on the machine) for testing.
Replace master
control panel.
Replace
pushrod.
Still does
not work
Works
normally
4-2.
Pushrod motor does not work
Pushrod motor does not work
Page 35
Johnson Health Tech. Co., Ltd.
Treatment:
Use engineering mode 2-4:P4 to detect, and refer to the air bag
location diagram
Check if the solenoid valve works normally
Check if each air channel connector leaks/air pipes are
compressed and shut off; connect and fasten again/replace aged air pipes
4-3.
Individual air bag can not be
Individual air bag can not be
inflated or inflated sufficiently
inflated or inflated sufficiently
Page 36
Johnson Health Tech. Co., Ltd.
Treatment:
a. First, rule out that the internal thermal protection of air pump is caused
by long-time operation
b. Judge whether the air pump works or not by listening to its sound.
c. Check if the solenoid valve works normally. No: Check air valve
connecting line or replace master control panel
No: check air pump
power supply
Normal (AC24-28V)
Replace air pump
Replace master
control panel
Normal
Abnormal
4-4.
All air bags do not work
All air bags do not work
Page 37
Johnson Health Tech. Co., Ltd.
Treatment:
First, rule out that the internal thermal protection of motor is caused by long-time
operation Use manual mode to force the motor to start, checking if it can be started. Enter P2 (refer to2-2) to check if the SENSOR corresponding to the poor motor triggers the
limit,
For example, when the front and back machine core motors cannot move forward, it is required to note that if the front limit lamp signal is triggered; when the front limit lamp is on, it represents that the lower control panel thinks that the machine core is at its foremost position and cannot go more forward
When the lamp signal is on, it represents the front limit is triggered
When the lamp signal is on, it represents the back limit is triggered
Sensor mode
Machine core
forward and
backward
4-5.
Machine core motor does
Machine core motor does
not work
not work
Page 38
Johnson Health Tech. Co., Ltd.
d. When using the engineering mode (e.g. P1) to drive the poor motor, use the electric meter to
measure if the motor corresponding plug on the machine core signal adapter board has DC24V output?
24V no check motor power line power line PASS replace master control panel
24V yes replace machine core (or replace machine core motor; kneading motor is not
suitable for field replacement; refer to Appendix I for the replacement of machine core
4-5.
Machine core motor does
Machine core motor does
not work
not work
Up and
down motor
Retreating
motor
Pounding
motor
Kneading
motor
Machine core
adapter board
Page 39
Johnson Health Tech. Co., Ltd.
J6800, J5800 and J5600 use the same machine core, and so the replacement method is the same; the only difference exists in outer shell disassembly sequence
Prepare materials as follows:
Prepare tools: screw driver, cable tie, diagonal cutting plier and
needle-nose plier
5-1.
Replace machine core
Replace machine core
Machine core unit
1 set
Page 40
Johnson Health Tech. Co., Ltd.
1. Turn off the power supply, and remove the outer shell’s 4 screws (4 screws indicated by red solid lines + 2 screws indicated by red dashed lines ).
1
5-1.
Replace machine core
Replace machine core
Page 41
Johnson Health Tech. Co., Ltd.
5-1.
Replace machine core
Replace machine core
2. Enter the engineering mode A0 (refer to 2-1), elevate the machine core to the proper height and cut the cable tie fixing the signal line
3. Use Phillips screwdriver to loosen the ground wire screws of the signal line
2
3
Page 42
Johnson Health Tech. Co., Ltd.
Loosen upper two screws
without removing them
4. Loosen the supplementary piece screws of the upper rail
5. Use the manual controller to operate
the machine core (refer to 2-1) to adjust
the position
6. Move the machine core roller to the upper position to prepare for removal
4
Remove lower two screws
5-1.
Replace machine core
Replace machine core
Page 43
Johnson Health Tech. Co., Ltd.
7. Be careful that the roller on the left side may eject; assist with hands
8. Make the rollers on the upper sides off the rails
9. Elevate until breaking away from rack engaging state
10. Unplug the power line and signal connecting line
11. Use both hands to remove the disengaged machine core
5-1.
Replace machine core
Replace machine core
7
8
Page 44
Johnson Health Tech. Co., Ltd.
12. Install the new machine core in the reverse sequence of removal
13. It should be noted that plastic gaskets are needed for the right-side roller of the new machine core and such materials can be obtained from the old core
14. It should be noted that spring and metal gaskets are needed for the left-side roller and such materials can be obtained from the old core
13
14
5-1.
Replace machine core
Replace machine core
Page 45
Johnson Health Tech. Co., Ltd.
15. After the machine core is installed, tighten the rail fixing piece
16. Lock the signal line ground wire on the set screws of the adapter board. The picture shows that the ground wire is not locked
17. And use the cable tie to fix the connecting line on the machine core metal plate. If the tie specification is small, use two or more ties for fixing. There are holes for fixing the ties indicated by red circles
Note: When the signal line is not securely fixed, it may
lead to occasional anomalies due to the loosened
signal line during the operation
16
17
5-1.
Replace machine core
Replace machine core
Page 46
Johnson Health Tech. Co., Ltd.
18. After the installation is completed, elevate the machine core to the upper limit and confirm that the sensor works normally, and adjust the metal plate properly to the center position (about 2 mm from both sides)
19. Lower the machine core to the lower limit and confirm that the sensor works normally, and adjust the metal plate properly to the center position
18
19
5-1.
Replace machine core
Replace machine core
Page 47
Johnson Health Tech. Co., Ltd.
Prepare the flash drive and software
J5800 software includes 2 parts
(all *.BIN files):
A. Manual controller application software jconsole.bin
B. Lower control panel application software jfitness.bin
It is recommended to install the software in the flash drive below 8GB to avoid that the
lower control panel cannot read the flash drive
It is recommended to store only the file folder jfitness in the flash drive to improve recording success
5-2.
Software update
Software update
Page 48
Johnson Health Tech. Co., Ltd.
Operational method:
a. Enter the engineering mode PU (refer to 2-5 engineering mode:PU) to confirm that if the software
version needs update
b. While the machine’s power is off, insert the flash drive with new software files to the USB line.
c. Press "start/stop" key on the manual controller to turn on the machine power switch (press the manual
controller power switch continuously)
d. Then, you will see the pounding lamp is on. Press the power key continuously and then you will see that
the pounding lamp keeps flashing
e. You will hear the relay’s motion sound 5 seconds after the pounding lamp stops flashing, and the update
is completed. Unplug the flash drive and test again by restarting the machine
5-2.
Software update
Software update
USB connector is hidden under the cushion
I: On / O: Off; when the power is on, the power switch light is on
Page 49
Johnson Health Tech. Co., Ltd.
1
1. Before adjusting the machine core’s advance and retreat current, confirm the current value first: Enter the engineering mode (please refer to 2-3) D0 to elevate the machine core to the half height (and confirm that the chair back is empty or not loaded; any load will affect the numerical value)
Proper height is indicated by the green portion in the picture; the cushion or leather cover, as indicated by the red portion, may affect the numerical value
Proper
height
range
5-3.
Adjust the machine core
Adjust the machine core’’s s
advance and retreat current
advance and retreat current
Page 50
Johnson Health Tech. Co., Ltd.
2. Then from P3->select D3
3. Press the “Air Strength” to select 2
4. Press the roller postion “wide” to make the machine core move forward. At this time, a number will appear and confirm that the number is not greater than 30
5. If it is greater than 30, adjust through the following steps;
2
3
4
5
5-3.
Adjust the machine core
Adjust the machine core’’s s
advance and retreat current
advance and retreat current
Page 51
Johnson Health Tech. Co., Ltd.
Steps as follows
1. Remove 6 screws on the outer shell of the massage chair’s rear cover
2. Enter the engineering mode A0 (refer to 2-1) to elevate the machine core to the proper height
Prepare tools: 3mm Allen key, 7mm open-end wrench, screwdriver and flathead screwdriver
5-3.
Adjust the machine core
Adjust the machine core’’s s
advance and retreat current
advance and retreat current
Page 52
Johnson Health Tech. Co., Ltd.
3. Loosen the screw nuts of the machine core’s advance and retreat motor set screws
4. Use the Allen key to loosen the screws for 1/4 circle
5. Tighten the nuts. Then use the Allen key to fix the screws to avoid turning screws when fixing the nuts
6. Do the same for the other 3 screws. A total of 4 screws require the adjustment
7. After the adjustment, enter the engineering mode D3 to check if the number is lowered to below 30
8. If the number is lower than 50, the adjustment is completed and machine is restored; if not, loosen for another 1/4 circle
9. If the adjustment is more than 2 circles, the replacement of machine core is recommended
5-3.
Adjust the machine core
Adjust the machine core’’s s
advance and retreat current
advance and retreat current
4
3
Page 53
Johnson Health Tech. Co., Ltd.
Right armrest
Manual
controller
Foot machine
unit
Foot
pushrod
Chair back unit
Seat Pad
Machine core
unit
Lower control
panel unit
Left armrest
Chair back
pushrod
5-4. Complete machine breakdown drawing
Page 54
Johnson Health Tech. Co., Ltd.
Up and down
motor
Front and back
motor
Kneading motor
Upper and lower
limits and upper
and lower numbers
Advance and
retreat sensor
Adapter board
Kneading
sensor
Pounding motor
5-5. Machine core breakdown drawing
Page 55
Johnson Health Tech. Co., Ltd.
Air valve
5-6. Lower control panel breakdown
drawing
Air pump
Transformer
Lower control
panel
Page 56
Johnson Health Tech. Co., Ltd.
Thank You