These instructions are provided to familiarize the user with the seal
and its designated use. The instructions must be read and applied
whenever work is done on the seal, and must be kept available for
future reference.
If the seal is to be used for an application other than that originally
intended or outside the recommended performance limits, John Crane
must be contacted before its installation and use.
Any warranty may be affected by improper handling, installation, or use
of this seal. Contact John Crane for information as to exclusive product
warranty and limitations of liability.
If questions or problems arise, contact your local John Crane representative
or the original equipment manufacturer, as appropriate.
ATTENTION
These instructions are for the installation and operation of
a seal as used in rotating equipment and will help to avoid
danger and increase reliability. The information required
may change with other types of equipment or installation
arrangements. These instructions must be read in
conjunction with the instruction manuals for both the
pump and any ancillary equipment.
John Crane mechanical seals are precision products and
must be handled appropriately. Take particular care to
avoid damage to lapped sealing faces and to flexible
sealing rings. Do not excessively compress the seal
before or during installation.
Safety Instructions
1. The following designations are used in the installation instructions to
highlight instructions of particular importance.
NOTE: Refers to special information on how to install or
Refers to special information or instructions directed
ATTENTION
Refers to mandatory instructions designed to
!
2. Installation, removal and maintenance of the seal must be carried out
only by qualified personnel who have read and understood these
installation instructions.
3. The seal is designed exclusively for sealing rotating shafts. The
manufacturer cannot be held liable for use of the seal for purposes
other than this.
4. The seal must only be used in technically perfect condition and
must be operated within the recommended performance limits in
accordance with its designated use set out in these installation
instructions.
operate the seal most efficiently.
towards the prevention of damage to the seal or its
surroundings.
prevent personal injury or extensive damage to the
seal or its surroundings.
Before Starting the Equipment
1. Check the pump at the coupling for proper alignment of the driver
or motor.
2. Ensure that the gland plate nuts/bolts are securely tightened
according to the pump manual instructions, and that all screws are
securely fastened.
3. Complete the assembly of the pump, and turn the shaft (by hand if
possible) to ensure free rotation.
4. Consult all available equipment operating instructions to check for
correctness of all piping and connections, particularly regarding seal
recirculation/flush, heating or cooling requirements, and services
external to the seal.
This mechanical seal is designed to operate in a liquid
ATTENTION
5. Check that the seal chamber fluid lines are open and free of any
obstruction, and ensure that the seal chamber is properly vented
and filled with liquid - refer to the pump instruction manual.
so the heat energy it creates is adequately removed.
Therefore, the following check should be carried out
not only after seal installation, but also after any
period of equipment inactivity.
5. If the pumped fluid is hazardous or toxic, appropriate precautions
must be taken to ensure that any seal leakage is adequately
contained. Further information on sealing hazardous or toxic fluids
should be obtained from John Crane prior to seal installation.
6. Fluorocarbon components should never be burned or incinerated
as the fumes and residues are highly toxic. If fluorocarbons are
accidentally heated above 400˚C/750˚F, they can decompose.
Protective gloves should be worn as hydrofluoric acid may be present.
7. PTFE components should never be burned or incinerated as the
fumes are highly toxic.
ATTENTION
!
WARNING:Seal installation should be handled only by qualified
Dry-running - often indicated by a squealing noise from
the seal area - will cause overheating and scoring or other
damage to the sealing surfaces, resulting in excessive
leakage or a much shortened seal life.
Before start-up, ensure that all personnel and
assembly equipment have been moved to a safe
distance so there is no contact with rotating parts
on the pump, seal, coupling, or motor.
personnel. If questions arise, contact the local
John Crane representative. Improper use and/or
installation of this product could result in injury to
the person and/or harmful emissions to
the environment, and may affect any warranty
on the product. Please contact John Crane for
information as to exclusive product warranty
and limitations of liability.
Page 2
63
BORE
SHAFT OR SLEEVE
0.040 LG. X 20˚ CHAM.
63
0D +0.000"
- 0.002"
0.040"
20˚
MOVE SHAFT IN AXIAL DIRECTION
BY HAND. NOTE MEASUREMENT
ON DIAL INDICATOR
MOUNT
DIAL INDICATOR
ON SHAFT
TURN SHAFT BY HAND AND NOTE
MEASUREMENT ON DIAL INDICATOR
MOUNT
DIAL INDICATOR
ON SHAFT
TURN SHAFT BY HAND AND NOTE
MEASUREMENT ON DIAL INDICATOR
MOUNT
DIAL INDICATOR
ON SEAL CHAMBER
FACE
TYPE 5625/5625P
DUAL METAL BELLOWS CARTRIDGE SEAL
eneral Instructions
G
1. Study the engineering layout drawing to confirm the proper seal
arrangement for the pump being used. Type 5625 and 5625P seals
are designed for versatility and can be assembled in various ways.
The following instructions describe the standard configurations.
2. To assure satisfactory operation, handle seal with care. Take particular
caution to see that the lapped sealing faces are not scratched or
damaged.
Typical Type 5625 Dual Metal Bellows Cartridge
Seal Arrangement
15
14
12
174651613218138
Inboard
Side
Preparing the Equipment
1. Check seal chamber dimensions and finishes.
Outboard
11
Side
Typical Type 5625P (Pumping Ring) Dual Metal Bellows
Cartridge Seal Arrangement
15
14
12
9
10
7
174651613218138
Inboard
Outboard
Side
3.Determine squareness of seal chamber face to shaft:
Rotating Mating Ring
- 0.005" FIM max.
Rotating Seal Head
- 0.002" FIM max.
Side
11
9
10
7
2. Measure axial end play (0.003" FIM max.).
NOTE: If measured dimensions exceed those values given, correct the equipment to meet specifications prior to seal installation.
4.Measure shaft runout (0.002" FIM max.).
Page 3
SLOT
WIDTH
M
N
SLOT
WIDTH
M
N
TYPE 5625/5625P
DUAL METAL BELLOWS CARTRIDGE SEAL
Type 5625 Dual Metal Bellows Cartridge Seal Assembly
Assemble the Type 5625 or 5625P as follows, referring to the applicable
engineering layout drawing.
NOTE: These instructions apply to a rotating mating ring configuration.
The seal assembly and mating ring positions could be reversed
should an application require.
NOTE: Elastomeric O-rings can be damaged or destroyed if care is not
taken. Prior to assembly of O-ring into groove, make sure groove
is clean and free of foreign materials. Lubricate both groove and
O-ring prior to installation with light lube oil (SAE #10 or #20) or
silicone grease (such as Dow Corning compound #4.) For ethylene
propylene elastomers, do not lubricate with petroleum products.
1. Place gland plate on table with gasket side facing up.
2. Install lubricated O-ring into outside diameter (OD) groove of mating
ring.
3. Stand sleeve on its base and slide mating ring over sleeve, align pins
and press in place.
4. Install set screws in collar.
5. Loosely attach the spacers to the collar with cap screws.
6. Set the gland plate assembly gasket side down on table. Install collar on
gland plate assembly and engage spacers into groove, aligning spacers
with pipe taps of gland plate. Uniformly finger tighten the cap screws.
This sets the radial spacing of the cartridge.
7. Install lubricated O-ring into outside diameter (OD) groove of seal
assembly rear adapter.
8. Insert seal head assembly in gland plate adapter, align pins and press
in place.
9. Clean faces of primary and mating rings with denatured alcohol and a
lint-free cloth.
10. Stand sleeve on its base and slide seal assembly over sleeve until seal
faces touch.
11. Install lubricated O-ring into ID groove of sleeve adapter.*
12. Slide sleeve adapter over sleeve, aligning pins of adapter with pins of
sleeve. Push down to engage drive flats until adapter stops at step of
sleeve.
13. Carefully slide snap ring over the end of sleeve. Using assembly tool,
push the snap ring in place inside the sleeve adapter until it snaps in
Type 5625 Dual Metal Bellows Cartridge Seal Assembly (cont.)
place. Be careful not to scratch the sleeve adapter!
14. Install lubricated O-ring into outside diameter (OD) groove of outboard
mating ring.
15.Slide mating ring over sleeve, align pins and press in place.
16. Install lubricated O-ring into outside diameter (OD) groove of outboard seal
assembly rear adapter.
17. Place gland plate onto table with gasket side up.
18. Insert seal assembly in gland plate, align pins and press in place.
Turn gland plate over and confirm that rear adapter is flush with
end of gland plate.
19. Clean faces of primary and mating rings with denatured alcohol
and a lint-free cloth.
20. Insert O-ring in face groove of gland plate.
21. Making sure seal assembly does not fall out, slide gland plate over
sleeve until seal faces touch.
22. Carefully rotate gland plate until holes in sleeve are lined up with the
collar set screws.
23. Carefully press down on gland plate and install snap ring over the end
of sleeve. Do not over compress gland plate or this may damage
the seal.
24. Tighten set screws until they start to enter the sleeve ID.
25. Uniformly tighten cap screws on spacers.
26. Install gasket and sleeve O-ring.
27. Pressure test according to John Crane Standard QA-5-0569.
*For 5625 or pumping ring for 5625P.
Typical Type 5625 Installation DimensionsTypical Type 5625P Installation Dimensions
1. Before starting the installation, read the following instructions carefully.
2. Remove the seal from its packaging, inspect for any damage, and
wipe clean.
3. The equipment should be clean and meet the specifications noted in
the “Preparing the Equipment” section. Lubricate sleeve O-ring with
lubricant recommended in chart below. Lubricate shaft sparingly.
Lubricate gland plate bolts/nuts as required.
4. Make sure the gland adapter gasket is properly positioned, and
that collar set screws do not extend past sleeve ID. Slide complete
cartridge seal assembly onto shaft. Position gland plate so pipe
connection #1 is at or near top dead center for ANSI pumps. For DIN
pumps, position gland plate so slot between pipe connections #2
and #3 is at or near top dead center. Slide cartridge onto studs (if
applicable) until gasket is flush against the face of seal chamber.
Hand tighten gland plate bolts/nuts.
5. Reassemble pump and make all necessary impeller adjustments.
6. Continue tightening gland plate bolts/nuts in an alternating pattern
until secure (1/4 turns, 180˚ apart), with gland adapter and face of
pump seal chamber metal-to-metal. Do not over-stress or distort
gland plate.
7. Tighten collar set screws evenly (1/4 turns, 180˚ apart), securing
cartridge seal to shaft.
8. Remove spacers and save.
9. Make appropriate piping connections to seal assembly.
Installing the Seal (cont.)
O-RING
GLAND BOLTS
SET SCREWS
SPACERS
CAP
SCREWS
Page 5
TYPE 5625/5625P
DUAL METAL BELLOWS CARTRIDGE SEAL
Installing the Seal (cont.)
The piping should follow the guidelines established in the John Crane
Manual LE-Plan 52/53-A. It is also recommended that a Plan 11 (bypass from discharge) be used with the standard Plan 52/53. For DIN
pumps rotate gland 135˚ CCW. Use port #3 as inlet and #4 as outlet.
Plug 1 and 2.
Preferred
Port #1 - Outlet/Vent
Port #2 - Inlet
Port #3 - Plugged
Port #4 - Plugged
Clockwise
Rotation
Plugged
Outlet “O”
Inlet “I”
Option #1
Port #1 - Vent
Port #2 - Inlet
Port #3 - Plugged
Port #4 - Outlet
The piping should follow the guidelines established in John Crane
Manual LE-Plan 52/53-A. It is also recommended that a Plan 11 (bypass from discharge) be used with the Plan 52/53. For DIN style
bolting pattern, rotate gland 45˚ clockwise. Same porting instructions
apply, Inlet 4 and Outlet 1. Do not utilize port #2 or #3 for the outlet.
Option #1 requires
manual venting of
entrapped air through
port #1 prior to start-up.
Port #1 - Outlet
Port #2 - Plugged
Port #3 - Plugged
Port #4 - Inlet
Inlet
Drain (Plugged)
Outlet
Plugged
Counter
Clockwise
Rotation
Decommissioning the Equipment
1. Ensure that the equipment is electrically isolated.
If the equipment has been used on toxic or
2. Ensure that the equipment is isolated by the appropriate valves.
hazardous fluids, ensure that the equipment is
!
correctly decontaminated and made safe prior to
commencing work. Remember fluid is often trapped
during draining and may exist outside the seal. The
equipment instruction manual should be consulted to
check for any special precautions.
Check that the fluid is drained and pressure is fully released.
Maintenance
No maintenance of a seal is possible while installed. Therefore, it is
recommended that a spare seal unit be held in stock to allow immediate
replacement of a removed seal.
It is recommended that used seals are returned to a John Crane Seal
Rebuilding Center, as rebuilding to as-new specifications must be carried
out by qualified personnel.
It is the responsibility of the equipment user to ensure that any
parts being sent to a third party have appropriate safe
!
handling instructions externally attached to the package.
Quality Assurance
This seal has been assembled in accordance with John Crane Quality
Assurance Standards and with proper maintenance and use will give safe
and reliable operation to the maximum recommended performance as
shown in any relevant approved John Crane publication.