IL4278
Recommended bulb
6 x 5 Watt G9 energy efficient LED
Bulb not included
Specification
Max power: 5W
Voltage: 220~240V, 50/60Hz
IP20
Weight 6 Kg
Please retain these instructions for future reference.
This symbol indicates that this product should not be treated as normal house-hold waste
and it should be recycled. John Lewis does not operate in store take back, but as members
of the Distributer Take Back scheme have funded the development and upgrade of recycling
facilities across the UK. Please take it to your nearest collection facility or for further details
contact your local council or visit www.recycle-more.co.uk.
We have taken great care to ensure that this product reaches you in perfect condition.
However, should any parts be damaged or missing please e-mail
lightingparts@JLPspares.co.uk
Trouble shooting:
Why is the light not working when switched on?
Check your power supply is switched on
Turn off light and check that the bulb is inserted correctly
Check the bulb is still in working order.
John Lewis partnership
171 Victoria Street
London SW1E 5NN
Johnlewis.com
Made in China
Issue 3 09/20
User manual
Gold Leaves 6 Light
Ceiling Bar
Thank you for purchasing this Gold Leaves Ceiling Bar. Please read the instructions
carefully before use to ensure safe and satisfactory operations of this product. Please
keep this instruction for future reference.
Warnings!
For your safety, this product must be installed in accordance with local Building
Regulations.
If in any doubt, or where required by the law, consult a competent person who is
registered with an electrical self-certification scheme. Further information is available
online or phone your Local Authority.
To prevent electric shock, switch off the mains supply before installing or maintaining
this product. Ensure other persons cannot restore the electricity supply without your
knowledge.
Always use the correct bulb type with the correct wattage as indicated in the specification
table. This product is Class I = and should be fitted to a lighting Supply (with earth)
protected by a 5 amp fuse or equivalent circuit breaker.
When changing the bulb, always switch off at the mains and allow the old bulb to cool
down before handling. Dispose of used bulbs carefully.
Caution! The bulb and surrounding parts can become hot during use.
For indoor use only.
Care instructions
We recommend cleaning with a soft dry cloth. Do not use abrasive materials as these
will damage the finish.
Replace bulb from John Lewis or established brand of the same type and compatibility.
Parts list
Assembly
Never install your appliance on a wet, freshly painted or plastered surface. Ensure the
house electricity supply is switched off at the fuse box. If removing an existing fitting,
note down all wiring connections. Check the fixings will not touch any existing wiring
before drilling and attaching the light to the wall.
Ensure you thread the wall wires through the black insulating tube fixed to the appliance.
IL4278
Step 1
Remove mounting bracket from fitting or fixing pack. Using the
mounting bracket as a template, mark and then drill the fixing
holes in the ceiling (ensure the screws are firmly fixed into a
solid or other suitable mounting and not just the plasterboard.)
Attach mounting bracket to the mounting surface using suitable
fixings. Do not attach fitting to mounting bracket at this stage.
Step 2
Step 2
wire are left out of the connector block. Ensure terminals and rubber sleeve are
correctly seated then close connector block housing.
Height Adjustment: The height of the fitting is adjustable prior to electrical
installation only. To adjust the length of cable, pull the metal support wire through into
the ceiling cup until the desired height is achieved. If you wish to lengthen the wire
again simply push the small tube that the wire passes through in on itself (it is spring
loaded) and gently pull the wire back through to the desired length As soon as the tube
is released it will automatically lock in position again. With the support wire length
achieved gently pull the supply cable through into the ceiling cup until the desired length
is achieved. Ensure that the supply cable is left slack so it is the metal support wire
taking all of the strain of the weight once installed and not the supply cable. Secure the
position of the supply cable using the figure 8 cord restraint that is fitted inside the
ceiling cup
Note: The weight of the fitting must be supported by the wires and not the
electrical cable.
Step 3
Carefully offer fitting over mounting bracket then secure in place with the screws and
any washers removed earlier.
Fit the bulb: type and wattage as indicated on the fitting. The wattage indicated
must not be exceeded.
Once installation is complete, the house electricity may be restored at the fuse box.
Ensuring that the power has been isolated, connect the electrical supply
wires to the connector blocks corresponding terminals. Make the
electrical connections as follows:
• Connect supply live (normally brown or red) to fitting live
(marked “L”) on the terminal block.
• Connect supply neutral (normally blue or black) to fitting neutral
(marked “N”) on the terminal block.
• Connect the supply earth (normally green/yellow or unsheathed)
to the earth (marked “ ”) on the terminal block
NOTE: Ensure electrical connections are tight and no loose strands of