Joerns Healthcare Oxford, Hoyer User Instruction Manual & Warranty

Redefining patient handling
Oxford®/Hoyer® Elevate
User Instruction Manual & Warranty
To avoid injury, read user manual prior to use.
Oxford®/Hoyer® Elevate
Afin d’éviter tout accident, veuillez lire attentivement la notice avant utilisation.
Oxford®/Hoyer® Elevate
Manual de Instrucciones y Garantia para el Usuario
Para evitar posibles daños, lea previamente el manual de usuario.
Oxford®/Hoyer® Elevate
Benutzerhandbuch und Garantie
Um Verletzungen zu vermeiden, lesen Sie bitte die Gebrauchsanweisung vor der ersten Benutzung.
Oxford
®
/Hoyer
®
Oxford®/Hoyer
®
Elevate
294000.10046 Rev. A
2
En g lis h
Manufacturer’s Contact Details
Contents
1. Oxford/Hoyer Elevate Patient Lift ..................................................................................... 3
2. Introduction: About Your Lift ............................................................................................. 4
3. Assembly and Commissioning Instructions ...................................................................... 5
4. Sling Guide ....................................................................................................................... 9
5. Lifting with the Oxford/Hoyer Elevate ............................................................................... 11
6. Safety Precautions
............................................................................................................ 12
7. Operating instructions ....................................................................................................... 13
8. Charging instructions ........................................................................................................ 16
9. Digital Weigh Scale .......................................................................................................... 18
10. Maintenance schedule & Daily check list ......................................................................... 22
11. Technical Specifications ................................................................................................... 23
12. Warranty ........................................................................................................................... 26
EUROPE
Joerns Healthcare Ltd
High Street, Wollaston, Stourbridge,
West Midlands DY8 4PS
ENGLAND
+44 (0)1384 44 66 22
Fax: +44 (0)1384 44 66 01
www.joerns.co.uk
USA
Joerns Healthcare Inc
5001 Joerns Drive, Stevens Point
Wisconsin 54481-5040
715-341-3600 800-826-0270
Fax: 800-457-8827
www.joerns.com
Oxford
®
Hoyer
®
Oxford®/Hoyer
®
Elevate
294000.10046 Rev. A
3
En g lis h
1. The Oxford/Hoyer Elevate Patient Lift
Removable Foot Plate
Electric Actuator
Adjustable Knee Pad
Sling Attachment Points
Spreader Bar (Cow horns)
Mast Extrusion
Rear Castor (braked)
Push Handle
Battery/ Control Pack
Front Castor (non-braked)
Digital Weigh Scale (optional)
Oxford®/Hoyer
®
Elevate
294000.10046 Rev. A
4
En g lis h
2. Introduction: About Your Lift
The Oxford/Hoyer Elevate is an electrically operated patient lift. Each Elevate lift is fully assembled, load tested and certified before being packed/shipped.
The packing consists of a strong, purpose built carton that is used for both export and domestic markets to ensure the safe arrival of the lift.
A number of documents are supplied in a wallet, and packed with each lift and should be kept safely for future reference.
• USER MANUAL
• DEALER GUARANTEE CARD (Europe only)
• CUSTOMER SATISFACTION CARD (Europe only)
• PACKING CHECK LIST
The TEST CERTIFICATE is an important document and will be required for your insurance records. It is valid for six months and after it has expired the lift should be inspected and serviced per the maintenance schedule.
Servicing and periodic testing can be carried out by your authorised supplier. Please ensure your lift is included in their maintenance schedule. If you are at all unsure what your local market servicing requirements are, please check with your dealer and/or a local government agency.
The Oxford/Hoyer Elevate is suitable for the following CATEGORIES of lift within the working parameters of the lifts specified in the TECHNICAL SPECIFICATIONS.
• Category A - Wheelchair
• Category D - Toilet/Shower Chair
Oxford®/Hoyer
®
Elevate
294000.10046 Rev. A
5
En g lis h
3. Assembly and Commissioning Instructions
CARTON CONTENTS
Place the carton in a clear working area and open carefully. The carton contains:
OXFORD/HOYER ELEVATE LIFT
WALLET CONTAINING DOCUMENTS
HAND CONTROL
BATTERY PACK
CHARGING LEAD
DESK TOP CHARGER/STAND
WARNING
The Oxford/Hoyer Elevate is heavy and will need to be lifted with care. You may need assistance to lift the Oxford/Hoyer Elevate from the carton.
ASSEMBLY
Remove the Elevate from the carton and place on the floor.
Oxford®/Hoyer
®
Elevate
294000.10046 Rev. A
6
En g lis h
1. Tighten the mast assembly with the mast-locking device, which is located at the front of the
chassis.
2. Turn the locking knob until hand tight.
3. Line the handle assembly up to the mast, and attach using the fasteners provided (these can be
found in the mast). The wrench needed to attach the handle is kept in the user instruction wallet for safe keeping.
CAUTION:
Ensure that the handle is secure and in place prior to using lift.
Oxford®/Hoyer
®
Elevate
294000.10046 Rev. A
7
En g lis h
4. Fit power pack to the lift and make sure the latch holding the pack in place is fully engaged.
“Click” in place.
5. Fit the hand control to the lift as shown. Once complete, check the hand control is functioning
correctly by referring to page 8.
DISASSEMBLY:
The lift should not be disassembled unless for service, repair or transport if necessary. Therefore follow the assembly instructions in reverse sequence.
Oxford®/Hoyer
®
Elevate
294000.10046 Rev. A
8
En g lis h
ALWAYS CHECK THE FOLLOWING BEFORE OPERATION
• The mast is fully locked into position.
• The red emergency stop button, located on the rear of the control box, is in the OFF (out) position.
• The legs of the lift open and close satisfactorily (This is done via the hand control).
• Push the up and down buttons on the hand control and confirm the boom rises and lowers.
Oxford®/Hoyer
®
Elevate
294000.10046 Rev. A
9
En g lis h
4. Sling Guide
The Oxford/Hoyer Elevate is suitable for patients in the SITTING position. The slings suitable for this device are listed as follows:
* Oxford/Hoyer Transport sling * Oxford/Hoyer Standing sling
USER GUIDE FOR STANDAID SLINGS
The Transport and Standing sling is an easy fit sling, suitable for standing and supporting. It is not a general purpose sling and patients must be assessed for suitability by a qualified person.
Transport Sling
Feed the sling down the back of the patient leaving the top of the commode aperture at the base of the spine. Check the roll part of the sling is square across the patient’s back.
Attach the support strap around the chest of the patient. This strap need not be tight. It is there to hold the sling in position whilst attaching the loops to the Standaid. It may be left off altogether if preferred. Ensure patient’s arms are on the outside of the sling.
Raise the patient’s leg and feed the leg strap under and up between the legs. Ensure the sling is not twisted or creased under the thigh. Repeat this procedure for the other leg. Attach the loops on the roll parts of the sling to the white hooks at the end of the hand grips.
Without crossing the loops on the leg straps, attach to left and right black knobs on the lifting fork. You would normally use the middle of the three loops. The patient is now ready to be raised from the seat. Once clear of the seat, the patient will be more comfortable if lowered back in to the sit­ting position.
NOTE:
Joerns Healthcare recommends slings are checked regularly and before use for fraying or
damage. Do not use slings that are worn or damaged.
Attachment Loop Straps: Shoulder
Attachment Loop Straps: Legs
Chest Supports and Buckle
Leg Supports