Jindara Barossa SRS2 Freestanding, Barwon SRS2 Freestanding Operation & Installation Instructions

Operation & Installation Instructions
Barossa SRS2 Freestanding
Please keep these instructions for future reference.Rev A 230574
Barossa SRS2 Freestanding 12
A.F. Gason Pty Ltd reserves the right to modify or alter specications, material etc. in the intrest of product improvement
WARRANTY
1. Subjects to clauses 2 & 3 of this Warranty, A.F. Gason Pty. Ltd. ACN 004 667 556 (Gason warrants the follow components of its heaters against defects in workmanship
n damaged by impact.
2. This extended warranty does not apply; a) if the heater is purchased from a person who has not been authorised by Gason to sell its products; b) if, in the opinion of Gason, the heater or any other component has been subject to abuse, misuse, alteration, modication or has not been installed, operated or maintained in
accordance with the instructions provided by Gason; or
,
c) to owners other then the original purchaser.
3. If you believe that the heater you purchased contains a manufacturing defect and you wish to make a claim under this warranty, please contact an authorised Gason service
centre to arrange for an assessment.
4. If, after assessing the heater, Gason determines that the heater contains a manufacturing fault, Gason may at its discretion: a) replace
the heater; b) repair or replace specic components of the heater; or c) provide a full refund.
5. Parts replaced under Warranty are warranted for the balance of their original warranty period.
6. If, at the discretion of Gason, the heater or any part needs to be replaced, serviced or repaired at an authorised Gason service centre, then the person claiming under this
Warranty must pay all costs a
ssociated with: a) returning the heater; and b) the delivery or collection of any new or repaired heater.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail
to be of acceptable quality and the failure does not amount to a major failure. Any benets you receive under these warranties are in addition to other rights and remedies that you may have as a consumer under a law in relation to the heater to which these warranties relate.
These warranties are given by: A.F. Gason Pty Ltd Blake Street Ararat VIC 3377 Please contact us if you have any queries o
n: Phone: 03 53522151 or email us via the “Contact Us” section of our website: www.gason.com.au
Barossa SRS2 Freestanding 2
Barossa SRS2 Freestanding 11
Troubleshooting
(Continued)
Read and follow these instructions carefully before installing and u
sing this appliance
S
AVE THESE INSTRUCTIONS
PAGE INTENTIONALLY BLANK
WARNING
!
WARNING
!
Safety Warnings
A ue re with resulting damage may occur if the appliance is not installed, operated and maintained as per this booklet.
Never place combustible materials such as wood, paper or furniture near the appliance.
This appliance is designed to burn dry wood. Do not burn rubbish, driftwood, flammable liquids or any substance containing salts or corrosives.
This appliance must not be installed and operated in an area where kerosene, petrol, paint thinner or other ammable
liquid is used or stored.
The ue system must be inspected and cleaned annually or sooner if required. Failure to do so could result in an excessive buildup of creosote which may result in a ue re which may damage the ue or cause damage to your home.
The surface of the appliance becomes hot during operation. Do not touch the surface of this appliance. Keep children away from this applianc
e during operation. Do not allow anyone to operate this appliance who is not familiar with this instruction booklet.
WARNING
!
Paint Curing and Care
Your heater is coated with the best available heat resistant paint. Even though t
he paint has been baked after application, it may require further temperature
c
uring. It may, if you overre the heater on its rst re, discolour. For your rst
t
wo or three rings, never exceed medium air setting and always have the fan
o
n when above low burn. Do not wipe the heater while the paint is curing. After
t
he paint has cured the only maintenance required to maintain the heaters nish
i
s to wipe it with a soft cloth. Do not use any commercial cleaners or solvents on
t
he paint nish.
W
e are proud of the presentation of our products. If at any time you need to
f
reshen up the paint, your local dealer has touchup paint available for purchase.
Y
ou may even change the colour of your heater if you wish.
If you have any enquiries, please contact the dealer from whom you purchased your heater:
P
LEASE COMPLETE:
D
ealer Name
D
ealer Address
Phone:
P
lease attach your original purchase dockets to this booklet for future reference.
Barossa SRS2 Freestanding 10
Barossa SRS2 Freestanding 3
Troubleshooting Installation
(Continued)
Smoke entering the room from the rebox when the door is open may be caused by
Insucient length of ue (ue to be 4500mm minimum underneath the base of heater to
underside of cowl)
Increase height of ue
Flue downdraught
Consult dealer or increase height of ue.
Creosote buildup in ue
Remove cowl and clean ue as per cleaning instructions. Check moisture content of wood.
Excessive ash build up
some woods will give large amounts of ash despite how you run the he
ater. Others will give you very little. Use the wood which is most convenient for you as long as it is dry. After a period of time you will get to know when to empty your unit. Bark will give you excessive ash. Try not to burn it. If you are burning wood that gives you charcoal, you may nd that after running the heater say for 8 hours at maximum burn rate, the charcoal builds up excessively. Overnight burn will reduce this charcoal back to a ne ash. If you are not ready to shut down for overnight burn when you next fuel the stove, load the stove with only one piece of wood and lay it across the rebox on top of the charcoal. Open the air control wide open and you will nd the charcoal will burn down with the one piece of wood. Repeat the process until the ash level is signicantly reduced.
WARNING
!
Installation
THE INSTALLATION OF THIS APPLIANCE MUST BE CARRIED OUT AS PER THIS MANUAL AND THE FLUE MANUFACTURERS SPECIFICATIONS.
WE RECOMMEND THAT YOU USE A QUALIFIED INSTALLER TO CARRY OUT THE INSTALLATION.
If you have any other enquiries, please contact the dealer from whom you purchased your heater. THIS APPLIANCE WEIGHS IN EXCESS OF 120 KILOGRAMS. EXTREME CARE SHOULD BE TAKEN WHEN HANDLING THE APPLIANCE.
A.F. Gason Pty. Ltd. accepts no liability whatsoever for any interpretation of AS/NZS 2918:2001.
I
t is important you understand these installation instructions and minimum clearances to combustible
materials before selecting
a position for your
Jindara Barossa
to ensure a safe and correct installation is achieved.
I
nstallation Permit
D
epending on your lo cal authority requirements, a permit may be required for the installation of your heater. It i
s
y
our responsibility to arrange the same.
C
learances
A
ll dimensions u sed in this document are in millimeters and are minimum unless otherwise stated. Thes
e
d
imensions state the minimum distance the Jindara Barossa can be placed in relation to any non-combustibl
e
m
aterials – plaster, wallpaper, timber, MDF etc.
I
n the instance your Jindara Barossa is surrounded by non-combustible materials – brick, stone, concrete, cemen
t
s
heet, villaboard or similar, wall clearances can be reduced to 100mm. A 100mm clearance is required to ensur
e
r
oom air can circulate around the woodheater while operating.
T
he Jindara Barossa freestanding heater conforms to AS/NZS 2918:2001 when positioned in relation to
c
ombustible surfaces as shown in the graphic on the following page.
H
earth Requirements
I
f the Jindara Barossa will be installed onto a non-combustible oor such as a brick, stone or a concrete slab with
t
iles etc. which is at least 18mm thick and extends at least 400mm in front of the appliance base, a hearth or oor
p
rotected may not be required.
I
f the Jindara Barossa is to be installed onto a combustible oor, a minimum 18mm cement sheet or similar non-
c
ombustible hearth or oor protector must be placed on top of the combustible oor. At a minimum, the oor
p
rotector must extend 400mm in front of appliance base. The protector must be at least 950mm wide and 930mm
d
eep. If desirable, the oor protector can extend to 1050mm deep to meet skirting boards or walls at the rear of
t
he appliance when installed as per the rear wall clearances.
F
or detail please see pictorial on next page.
Barossa SRS2 Freestanding 4
Barossa SRS2 Freestanding 9
Installation Troubleshooting
Corner Installation
Standard Installation
(Continued)
• Noisy Fan
Turn the power o and remove the three pin plug from the power point. Remove the four screws that hold the front fan access panel. Remove the panel. Disconnect the wiring loom via the plastic joiner. Unscrew the nut which hold the fan in position and remove the fan. Clean any dust with a dry paint brush and vacuum the fan blades. Clean around the motor. After completion place two or three drops of sewing machine oil on the shafts at the bearings. Replace the fan in reverse to the removal.
• Fan not working
Check the power connection with another appliance. If the power point is okay assume the Fan or the Switch is defective. Isolate the power as above. Check that the terminals on the loom and the switch are rmly connected. If the fan then fails to function, remove the fan and switch by rstly removing the knob o the fan switch by pulling it away from the heater. Undo the holding nut and pull the switch out. Disconnect the wiring from the power lead and remove the
fan and switch. Convey the same to the authorised Eureka Dealer from whom you purchased your unit for service.
Replace in the reverse order.
• Air Control Jamming
Lift up and remove the top plate. Remove the air control knob by turning anti-clockwise. Lift the air control panel out of the way. There are three bolts holding the air slide in place. Undo them and remove the air slide. Wipe any ash or dust that may have accumulated on the back of the air slide or on the face of the heater. If any burrs have developed on the back of the air slide or on the face of the heater, rub them o with ne wet and dry sand paper till you have a smooth surface and edges. Replace the air slide and make sure the washers and spacers are on the bolts when you screw the bolts back into the face of the he
ater. Do not apply any type of lubricant to the air slide whatsoever as this will attract dust and make the
slide stick.
• No Overnight Burn
Remove the air slide as per air control jamming and check that the air slide is hard against the face of the heater. If it is loose, tighten up the bolts holding the air slide to the face of the heater. Do not overtighten. Check that the door rope has an even indentation from the sealing strip, which is on the face of the rebox. If it is uneven and it appears as though air could leak through the seal, adjust the thickness of the door rope to suit. Stretch the rope to make it thinner where the indentation is the heaviest and bunch up the excess where the indentation is smaller. Check the four bolts that hold the glass retainer in position. If loose tighten. Do not overtighten. The door may become loose through the door seal shrinking. To tighten the door, open the door and look at the inside of the
door shaft. Unscrew Allen key screw in door handle shaft. Rotate door handle shaft anti-clockwise when facing heater (1 turn = 1 millimetre). Close door and lock. Open door and check door for even indentation from sealing strip. Repeat process if required. Replace Allen key screw (check to ensure that roll pin is central in shaft.) When closing the door you should now feel rm resistance when the latch comes into contact with the catch.
WARNING
!
Overring
NEVER OPERATE THE HEATER WITH THE DOOR LOOSE AND DO NOT AIR TIGHT OVERFIRING COULD RESULT IN DETRIMENTAL WEAR AND TEAR ON THE FIREBOX.
18
Barossa SRS2 Freestanding 8
Barossa SRS2 Freestanding 5
Operating your Eureka
Installation (continued)
Operating your Jindara Wood Heater
(continued)
Cleaning your ue
Carefully remove bae plate and put it to one side. Close the heater door. Obtain a 150mm ue brush from your local Jindara Dealer and proceed up onto your roof. Remove the cowl. Slowly push the ue brush down the chimney until it stops. Pull the brush back out and repeat the process. Each time you do this you will notice that the brush will go further down the chimney till it reaches the bottom. The soot and creosote will fall down the chimney and into the rebox. Clean residue from rebox. Replace the bae plate. Make sure you do the job well. The cleaner the ue the less chance there will be of the creosote sticking again. After you have replaced the cowl, inspect the roof ashing for any damage that may have been incurred whilst you were cleaning the ue. Reseal the seal on the roof with roof and gutter silicone if required.
The fan
It is recommended to run the fan while the heater is operating above low burn on low speed. For extended periods when the heater is running above medium re, high or boost is recommended. Boost is recommended for short bursts where a quick temperature rise is desired in conjunction with a high re setting. The fan should be cleaned on a regular basis. (Refer Troubleshooting for fan removal and cleaning.)
WARNING
!
Operation of the fan
If rebox failure is reported and it is found that the rebox has been abused
through improper use of the fan, Jindara reserves the right to disallow any warranty claims in relation to rebox failure.
WARNING
!
The Door
Leaving Door Open
As stated previously in relation to leaving door open 25mm to encourage the re to pick up at a faster rate, your heater has been tested to ensure that no
structural damage can take place if the door is inadvertently left open. However your paint nish can be damaged if the door is left open for a long period with a full rebox of fuel with the fan o. Closely supervise your heater while the door is left open.
Closing the Door
Always ensure that before you close your door there is no wood protruding beyond the front of the rebox opening. Do not use the door glass as a ’battering ram’ to push the wood back into the rebox. Damage to the glass by such impact is not covered by your Warranty.
Flue Installation
T
he ue system must comply with Australian and New Zealand installation standards AS/NZS 2918:2001, and
i
nstalled to the ue manufacturers instructions.
T
he preformance of your Jindara Barossa is highly reliable on an eective ue system. In many cases poor start-up,
d
irty glass, down draft which causes smoking when door is open, and a reduction in heat output can all be related
t
o ue been too short, or incorrect installation. Too tall a ue can result in excess draft and short burn times along
w
ith excessive heat output.
T
he rear wall clearances mentioned above have been achieved with the following ue specications.
1. 150mm – rear wall clearance with an AS/NZS 2918:2001 approved ue kit, which incorporates a decroative surround which is unperforated for 180 degrees of its circumference. Additionally a 180 degree x 900mm stainless steel heat shield located inbetween the 6” active ue, and decroative surround (supp
lied with woodheater).
Barossa SRS2 Freestanding 6
Barossa SRS2 Freestanding 7
Installation (continued)
“C” angle iron bracket
re bricks
bevelled edge
Bae Plate
Take the rebricks out of the heater. They are to be placed so that they stand on end against the rear and two side walls of the rebox. You will notice that the bricks have a bevel on one end. Inside the rebox there is a “C” shaped angle iron rebrick retaining bracket. This is designed to sit over the bricks and hold them in place. This should be placed in the rebox so that you see a at face of the angle iron on both sides of the rebox and at the rear of the rebox. Holding the “C” frame up to the top of the rebox, insert a whole rebrick, standing it vertically with the bevel edge pointing down and facing inwards toward the left hand side of the rebox. Lower the left hand side of the “C” frame onto the rebrick. Repea
t with a whole rebrick on the right hand side. Place rebricks (3 whole rebricks) using the same method against the back wall of the rebox. Now place one extra whole rebrick on either side of the rebox to complete the installation of the rebricks. (i.e. two each side and remainder on the back wall.) Push each brick and “C” frame rmly against the wall of the rebox and you are ready to light your re.
Placement of rebricks in rebox
Fitting the Bae Plate
1. Feed the bae plate through the door opening with front edge folded up all the way to the rear of the heater.
2. Lift front over Pin A and slide towards front of heater.
3. Lift rear so the bae plate is horizontal and move towards back of the heater.
4. Lower over Pin B.
5. Bae
plate must be sitting on Pins A & B.
Final inspection prior to use
Ensure the bae plate is rmly located.
Ensure rebrick liners – sides and back are positioned correctly.
Check fan cord has not been damaged during transit.
Plug in fan cord and ensure cord does not touch stove surface.
Check all door seals are tting correctly.
WARNING
!
DO NOT ATTEMPT TO OPERATE THIS APPLIANCE WITHOUT READING AND UNDERSTANDING THESE OPERATING INSTRUCTIONS THOROUGHLY. FAILURE TO OPERATE THIS APPLIANCE PROPERLY MAY CAUSE UNDUE DAMAGE TO THE APPLIANCE OR RESULT IN A FLUE FIRE.
Read these instructions
Operating your Jindara Wood Heater
Starting your re
Place a relighter or paper in the bottom of the rebox and place a large amount of small kindling on top. Ignite the paper or the relighter. Set the air control to high and leave the main door open approximately 25mm. When the kindling is burning, place about four pieces of small wood on top of the burning kindling. Once the wood is alight, close the main door. After approximately 20 minutes, turn the air control down to medium and, turn the fan on to low speed.
On the initial re up you may detect smoke coming from the paint nish and from any oils that may be on the steel on the outside of the rebox. This is normal. It is suggested to well ventilate your home on the initial re up. Please refer to our section ‘Paint Curing and Cure’.
The glass door
Always operate your heater with the door closed and locked. The only time you can leave the door open is on initial lighting, or when
reloading the heater.
Care of your glass
If you are burning good dry wood, you will have very little discolouration of your glass in normal burning cycle. If you aim for an eight to ten hour overnight burn, you should not get much discolouration. You can control this by adjusting the air control, moving from the left and slowly creeping the control to the right. After a number of days you will nd the right position to suit your requirements and the fuel that you are using.
Cleaning the glass
Generally the only time you will possibly need to clean your glass is after a long overnight burn. If you nd that you have a wet sticky black lm on your glass (creosote), it is better to burn the heater as normal for one load of wood. When the wood has burnt down to a hot bed of embers, open the door and leave it wide open until the glass cools suciently
to be wiped with a damp cloth. This should clean all the white smoky lm o the glass. Creosote on the glass is normally a sign that you have tried to get too long an overnight burn or you have burnt excessively wet or green wood.If the lm on the glass won’t come o with a wet cloth, you can use wet ash from the ash bed as a cleaner or commercial products such as Crystal Clear, Johnson Foam Clean or Windex.
Normal Operations
When you get up in the morning, open up the air control of the heater to high position to start the embers glowing. Place three or four pieces of wood on top of the embers and leave the door open 25mm. Once the fuel starts to ame close the door. As the heater starts to heat up turn the fan on to low, (approx 20 minutes) and begin reducing the air control towards a lower setting.
You will nd with the
fan on low you will only need to run the heater between low and medium to maintain the temperature you desire in your home. To obtain the maximum heat dissipation from the heater it is necessary to run the fan at any time the heater is running above the low position.
For best results it is best to burn 260mm long wood and load your wood straight into the rebox front to rear. This will give optimum eciency and recoverable heat, and minimise creosote formation and smoke emissions.
Overnight burn
Approximately 30 minutes before turning the heater down to overnight burn it is recommended to load the heater with fuel for the overnight burn. Leave the air control in the medium to high position. Let the heater run for about thirty minutes. This will reduce the moisture content in the fuel before shut down. (This will help reduce the creosote formation in the rebox and ue.) Set the air control to the setting you have
found best for your requirements. Turn the fan o and retire. The aim when overnight burning is to have only a few hot embers left in the bottom of the rebox in the morning. Not huge lumps of wood.
Loading...