Jiangxi Jade IOT Sensing Technology JD GP11 User Manual

User Manual
GP11
CREATING SECURITY SOLUTION
Specifications
32 wireless zones and 2 wired zones Periodic supervision for wireless PIR and magnetic switch App(available in Google play and Apple store) control Window/door open remind User account / zone naming GSM/SMS alarm selectable Built-in rear tampers for control panel 200 event logs with time indication Built-in siren (85dB), compatible with wired external siren and 3 wireless sirens Alarm linkage output: PGM x1 AUX power output x1 4 for private phones Numbers(or mobiles) 8codes: 1 for installer, 1 for master, 1 for temporary, 1 for duress and 4 for users Support 6 keyfobs Support 6 RFID Tags
Introduction
Introduction
General System Overview
Thank you for choosing our wireless alarm kit, which offers an innovative all-in-one solution with all aspects of security and connectivity covering a full range of wireless accessories.
Window / Door Open Remind
The Control Panel can recognize and record the door contact condition. Users can set as forbid arm or allow arm but with remind system problem. Also can choose to close the “Window / Door Open Remind”
User Account / Zone Naming
Each Wireless Zone / Code can be given a 16 character name. Names can be given either when first adding a Zone / Code or by editing them later. All names can be deleted only in “Initialize All”. The name will be show in event log or SMS.
APP Control
After install the APP software, users can use smart phone to control some function of panel, like: Arm, disarm, bypass, turn on / turn off siren etc. each processing in APP, mobile phone will send one charge SMS to control panel.
CONTENTS
Number Of Devices
Users can install up to 32 wireless devices to the system. including door/window contacts, PIRs and smoke detectors, up to 2 wired detectors, 6 keyfobs, 6 RFID Tag, 3 wireless sirens, 1 wired siren and 1 PGM.
Featuring GSM dialing or SMS send optional, it offers multiple performance options and the flexibility.
Supervision For Accessories
Activating periodic supervision for accessories, it ensures system safety.
1 Easy Install
2 Using System
3 Using System - More Details
4Menu System in Detail
5Troubleshooting
6 Parameters
7Appendix
1: Easy Install
CONTENTS
After unpacking the kit and making sure that you have all the necessary equipments, it is recommended that you install the system as following:
Step 1: Open the housing
Step 3: Connect external devices
Figure -3-
Step 2: Insert the SIM
Figure -1-
Figure -2-
-02-
Wired Siren Connection
The max drive of BELL terminal is 400mA / 12VDC. Connect the bell power line to “BELL” and “GND”. Users can try to program via keypad to set if the siren beeps and how long it beeps.
Note: The wired siren is invalid with backup battery.
only
AUX Power Output Terminal
AUX supplies power output for wired detectors (AC Operated: 10-12V, Battery Operated: 6-8V, max current: 100mA. It may cause abnormal working for wired detector under low battery).
Alarm Linkage Output: PGM
The maxload of PGM output is DC25V/500mA. Boolean value is output with PGM on connected with GND of PCB board.
PGM can connect to wired siren, indicator, electronic lock(Figure 4-1), and it also connect CCTV camera and DVR for alarm input(Figure 4-2).
Low voltage device / control module
External Power
(İDC25V)
Figure -4-1-
Figure -4-2-
-03-
Alarminput
Setting PGM trigged by programming setting, when meet trigged condition, PGM connected, see pages related to PGM
PGM only compatible with low voltage (DC) control board. It shall not be connected with city
Note
power (AC) directly.
Wired Devices Connection
The system supports different kinds of wired detectors with EOL resistance. Please connect as following:
N/C detector
N/O detector
The system will keep the time and date with time chip powered. If the power of time chip runs out, users need to re-set the time manually. The icon will move to next automatically after each input. Press “ * ” to exit. After complete input, press “#” to confirm. If the input is not finished, and meanwhile “ * ” is pressed, it will display on the LCD “Invalid Set!”. Pls press “ * ” to re-input it.
There will not alarm when anti-tamper was trigged, only flashing remind, In three hours power on.
Note
Step 5: Register Transmitters
Transmitters refer to wireless devices such as detector, magnetic contact, siren and keyfob, etc. Only after enrolling can transmitters be recognized by the control panel.
To register a device:
1. During disarm, press “ ”. With voice guide “Enter password before setting parameters!” Input the installer code with “ # ” .
2. For specific register process, pls refer to Device Set/Zone/WL.Register.
Figure -5-
Step 4: Power on the control panel
Re-check the wiring and make sure all connection is correct. Connect the AC power adaptor and turn the backup battery on.
Parameters of power adaptor: Input: 100V-240VAC 50/60Hz 0.5A, Output:12VDC 1.5A. Backup battery: 7.2V 800maH Li rechargeable,24 hours is required for full recharge which can last around 8hours for this system under standby situation. After low battery warning,it can work for around 30 minutes.
-04-
Please take off the battery before enrolling, and then enroll one by one with battery connected. While users register with battery on for all devices, there may come wireless
Note
signa linterference and make enroll fail.
Step 6: Testing the Chosen Mounting Location
Once all of the transmitters are registered, it is recommended that users test the chosen mounting locations before permanently mounting the control panel and wireless devices. Users can test the transmitter signal strength using the TX Test feature.
Transmitter Test:
1. During disarm, press “ ”, with voice guide “ Enter password before setting parameters! ”. Input the installer code with “ # ” to enter.
2. Select “8.Aided Test” ĺ“# ” ĺ“ 3.Transmitter test”ĺ“ # ”.
3. Trigger the desired devices, and the info about them will display on the LCD.
4. After all test, press “ * ” to exit.
-05-
Walk Test:
1. Enter Menu.
2.
Select “8.Aided Test” ĺ “ # ” ĺ “2.Walk Test”ĺ “ # ”.
3. Trigger the desired devices, and the info about them will disappear on the LCD.
4. After a ll test, press “ ” to exit.
Test GSM signal:
The communication signal strength should be tested to confirm if GSM module work well.
To test GSM signal:
1. Enter Menu. 2
Select “8.Aided Test” ĺ “ # ” ĺ “4.GSM Test”ĺ “ # ”. 0-31 means for the signal strength. 31 means the strongest. To make sure normal
communication, pls use over 12.
InstallingGHoleGDrawing
Wall Wall
Figure -6- Figure -7-
While hanging the control panel, please don’t shake the product to avoid breaking the tamper switch
Step 7: Permanently Installing
In order to optimize wireless communication, consider the following guidelines:
1. Whenever possible, mount the panel centrally in relation to wireless sensors.
2. Avoid installation in close proximity to sources of high nois
interference. air conditioner, heater or circuit breaker boxes.
For example,
3. Minimize the distance between the panel and transmitters.
4. Minimize the number of obstacles between the panel and transmitters.
5. Metal based construction materials, such as steel reinforced concrete walls, will
reduce the range radio transmissions
of
Having chosen and tested the mounting location of the control panel and each transmitter, it is ready to permanently install the panel.
At first, stick “Installing Hole Drawing” on the location for control panel. Drive 2 screws on the fixed position , and then hang the control panel directly on the screws. While driving the screws, pls pay strict attention to the depth of screws to make sure easy hang and tamper switch work normally. There are one tamper switches: rear tamper. Compress the tamper switch while installing. If the control panel is removed or opened, tamper will be triggered.
-06-
e or radio frequency
2: Using System
Arm and disarm the system and practice using it. Trigger the alarm by arming the system and opening protected door/windows and walking past PIRs.
Disarm
Arm-away
Arm-stay
Panic
Figure -8-
Figure -9-
-07-
Front Panel Keypad
If under arm stay, press “ ” on keypad or keyfob, the voice will guide “Arm stay”.
For arm away
For arm stay
For disarm, and also for fire alarm(press for 2s)
For programming, and also for panic alarm(press for 2s)
Figure or navigation key for up turn, for menu operation or query
Figure or navigation key for down turn, for menu operation or query
It means ಯdeleteರwhileinputtingfiguresorquitformenuoperation
Forenter
Arm/Disarm via keypad or keyfob
Users can arm away, arm stay, disarm or emergence via keypad or keyfob. Arm or disarm is not available during programming or trouble query. Via keypad requires master / user code, while via keyfob requires no code.
(1) Arm Away
When the system is under disarm, press “ ” on keypad or keyfob, the status LED turns from Green into Red with the voice guide “Arm away, close door and window, exit delay”, with the music. When the exit delay ends, the voice guide will sound “Armed away!”
If during zone alarm, press on keypad, or keyfob, the voice will guide “Disarm before arm!” If under arm situation, press “ ” on keypad or keyfob, the voice will guide “Armed away!”
(2) Arm Stay
It enables users not to alarm in active zone but alarm in other zones. If under disarm, press on keypad or keyfob, the status LED turns from Green into Red, the voice will guide “Arm stay”.
If under arm away, and with no alarm, press on keypad, the voice will guide “Enter password!” Users can enter arm stay status with code input or direct keyfob operation.
If under zone alarm, press on keypad or keyfob, the voice will guide “Disarm before arm!”
“ ”
“ ”
“ ”
(3) Disarm
“ ”
Press on keypad or keyfob, the voice will guide “Enter password, / add 0 to delete the
event log .
Disarm with alarm list cleared:
Input the code( ) ending with “ 0 ”, and “ # ”, the arm LED turns from Red to Green with the voice guide “Disarmed, alarm log eliminated!”
Disarm with alarm list saved:
Input the code (except installer code) ending with just “ # ”, the arm LED turns from Red to Green, with voice guide “Disarmed!”
except installer code
Note: If disarm by keyfob, the alarm list will be saved.
(4) Window/Door open remind
When magnetic contacts are registered with control panel, if the panel don't collect the close signal from them, and it will cause failure when arm away (arm-stay) the system. This failure will be indicated with voice Window or door is open, Arm failed.” and SMS message will send as long as it is selected.
a) The interfering will cause the signal failure of wireless signal, then Arm failure. At that situation, please separate and close the magnetic contacts again to make sure Arm successful. For security reasons, it is strongly suggested to make sure every arm successful. This can be audio confirmed by internal siren sound and SMS massage. To set the internal siren, refer to
Note
page 24 “Call Back When Arm/Disarm”.
b) If users want to ignore the open area remind, please refer to page 27 to turn off this function.
Arm/Disarm via RFID Tag
Users can only arm away or disarm via RFID Tag.
Arm or disarm is not available during programming or trouble query or Zone alarming.
Trigger alarm via keypad
It enables users to trigger alarm via keypad or keyfob in emergency.
Trigger panic alarm:
-08-
-09-
Press ಯ ರonkeypadorಯ ರonkeyfobfors.
Trigger fire alarm:
Press ಯ ರonkeypadfors
SMS Operation
Users can proceed arm-away/arm-stay/disarm/status enquiry operation by sending SMS to control panel. Please check below two ways of operation:
Method 1: Edit SMS manually, then send to control panel
Suppose xxxx is user password. Users send SMS (passwordxxxxarmaway) to control panel, can realize arm-away; send SMS (passwordxxxxarmstay) to control panel, can realize arm-stay; send
Figure - -11Figure - -10
SMS. (passowrdxxxxdisarm) to control panel, can realize disarm.
Tele-control via phone
Users can remote control the control panel via telephone, such as arm-away, arm-stay, disarm, repeat alarm voice, and turn on / off site siren, etc. Users can call the phone number set in the control panel. After ring attempts set, it will pick up with voice guide to input password ending with “#”: “For arm- away, press 1, For arm-stay, press 2, For disarm, press 3, For alarm repeat, press 5, turn-on siren, press 6, turn-off siren, press 7, Hang up, press 0”.
Pressing any key during voice play may cause communication error. It is suggest to operate after voice. If the system is under programming, remote controlling is
Note
not available. There should be no voice indication during remote .
on control panel or phone
controlling
Dial to alarm via panel
The control panel will cal voice alarm after pick-up and voice alarm will repeat after 5s stop. It will totally repeat 5 times. The control panel will automatically hung up in 5s after the 5th alarm. If there is no voice alarm after pick-up or users don't want to wait, users can press “5” on your mobile and the control panel will start playing voice alarm. Users can operate the control panel during voice alarm stopping time, before the panel automaticall
See following: Disarm: press “3”. Arm-away: pr ess “ 3” to disarm and then “1 ” to ar m away. Arm-stay: press “3 ” to di sarm and then “2” to arm s tay. Repeat alarm: press “5” to repeat the alarm. Note: Alarm is not available to repeat after disarm. Turn siren: press “ ”.
on 6
Turn siren: press “ ”.
off 7
Hang up: press “0” to hang up directly and the system will not dial any phone number.
l pre-set phone numbers when alarm triggered. Users will hear
y hung up .
For example: suppose user password is 0808, then the exact operation is as follow:
Arm-away SMS
password0808armaway
ID: 1234 Prog: Arm away Act:OK
ID: 1234 Prog: Arm away Act:ERR
Operation succeeded or failed reply:
Arm-stay SMS
password0808armstay
ID: 1234 Prog: Arm stay Act:OK
ID: 1234 Prog: Arm stay Act:ERR
Operation succeeded or failed reply:
Disarm SMS
password0808disarm
ID: 1234 Prog: Disarm Act:OK
ID: 1234 Prog: Disarm Act:ERR
Operation succeeded or failed reply:
-10-
-11-
Arm/disarm status check:
password0808status
Reply format:
Note
ID: 1234 STAT STAT STAT
: Arm away
Act:OK
Arm & disarm is not allowed when programming; when zone alarm, it will not arm,
meanwhile it will fail and return back.
ID: 1234
: Arm sta y
Act:OK
ID: 1234
: Disarm
Act:OK
Method 2: By using application to send SMS.
Users need to install Android or IOS APP correctly. Then operate the alarm system as to the operation hints in the interface. Every operation will send a message to the panel.
App Setting Steps:
1) Add control panel
ķ Click “ ALARM SETTINGS ” ĸ Click Create New Profile ”
Ĺ Enter the Profile Name, any character name can be input, this name will appear in the panel list; Enter the alarm phone number, must be SIM number in the control panel; Enter the User code, can be master or user or temporary code.
ĺ Set the function of . Function can select as below.
Ļ Click “ SAVE SETTINGS ”. Click “ SAVE SETTINGS ” to finish setting.
2) Choose profile
In control panel list, click control panel's name, then click “ Select ” button to enter the main interface. If users need any change, please click “ Edit ”.
3) Operate control panel
Arm away Disarm
Arm Sta y Will proceed the function set above.
Each time operates a button, it will send out a paid SMS. We suggest wait for 30 seconds
to proceed next operation after one operation.
Note
Send SMS for Alarm / Arm / Disarm
It enables the control panel to send SMS message
to the set phone number or SMS center for alarm,
or arm / disarm.For example,the control panel ID
is 1234, when zone 2 (Hall) fire alarm, it will send
SMS as following:
ID:1234 ZONE: 002 hall EVENT: FIRE ALARM
2017 - 02 - 01 17:12
-12-
-13-
3: Using System –More Details
Display Interface
Users may meet following symbols or marks:
Alarm Type and Way
There are two alarm type: instant alarm and delay alarm. Trigger 24-hour zones, instant alarm will occur. 24-hour zones include: fire zone, gas zone, panic zone, duress zone, and tamper zone.
Note : For 24-hour zone, whether it is armed or disarmed, once triggered, it will alarm immediately.
¥
Selected for Multiple-choice
Unselected for Multiple-choice
Counting down
Confirm to enter for details
System Trb.
Alarm List
Trb. List
Untreated
Treated
System trouble
Display of alarm events
Display of trouble
It means not disarmed after alarm.
It means disarmed after alarm.
Alarm Display
The alarm will display with voice guide in the Alarm List. Press to select with “ # ” to query the event. Press “ to quit.
Alarm List
Kitchen Untreated
Alarm ---------- Untreated
Zone: 01 k itch en
Type: Pan ic
Tim e: 0 1 / 0 2 / 2 0 1 7
“ / ”
10:35
Alarm delay occurs with voice indication as “Alarm, please disarm!” when the entry delay zone is
triggered. Before the music ends, please disarm, Or if users disarm after the music, the message
will be sent. Entry delay happens for entry/exit zone and active zone only.
1. For entry/exit zone, only during arm away and arm stay, the zone be triggered with
alarm delay.
2. For active zone, only during arm away, the zone be triggered with alarm delay.
Note
3. When alarm already happens in other zone, and with this zone triggered again, the panel
will
will alarm immediately with no indication of entry delay.
Table 1: Different alarm type and zone type determines different alarm way
Alarm type
Fire zone
Gas zone
Panic zone
Perimeter zone
Active zone
Entry/Exit zone
Duress zone
Tamper zone
AC loss
Low battery
WL. loss
Low battery for WL.
Dial phone
Yes Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Send SMS LED Siren
ON
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
ON
ON
ON
ON
ON
ON
will
Ring(cut-off adjustable)
Ring(cut-off adjustable)
Ring(cut-off adjustable)
Ring(cut-off adjustable)
Ring(cut-off adjustable)
Ring(cut-off adjustable)
Not ring
Ring(cut-off adjustable)
Not ring
Not ring
Not ring
Not ring
-14-
-15-
Keypad Lock and Unlock
If the code is input wrong, the voice will guide “ Wrong password, please re-input! ” And if the code is input wrong for 5 times,the voice will indicate “Access locked, please try later! ”DŽ After the code is locked, and operate any step which requires code, the voice will guide “ Access locked, please try later! ”
If the code is locked when there is no alarm, but alarm occurs after the code lock, the system will auto release the code lock. While if the code is locked after alarm, auto release must be available after system re-initializa
tion, or within 30 minutes.
Codes Access
There are 5 types of codes: master code, installer code, duress code, temporary code, and user code (4). Different authorizations are appointed for different codes.
Ĝ means for authority(“ ” ):
Code Type
Master Code
Installer Code
Duress Code
Temp Code
User code 1
User code 2
User code 3
User code 4
Arm&disarm
Enter Menu Code Set “Programming” in menu
Editable
Clearable
Remark: ķEnter by master code, users can set all codes except installer code. 
ĸEnter by installer code, can only set installer code.
users
Code Restore
If users forget code, it need power off the panel, open the panel back, turn jumper to “default” mode, restart the panel to restore code to factory default setting. Then users should turn jumper to another side, or the panel will restore code when restarting panel next time.
Zone Description
There are 8 types of zones: entry/exit zone, active zone, perimeter zone, panic zone, fire zone, gas zone, tamper zone and duress zone. There are 38 zones: zone 1-16/31~46 is wireless. Zone 17 is panic. Zone 18 is duress. Zone 19 is fire. Zone 21-22 is wired. Zone 30 is tamper. Different zone type alarms in different ways. Tamper alarm is valid with 24 hours for wireless zone 1-16 . with tamper alarm indication.
Table 2: Zone Type
Zone
Type
Entry/Exit
Active
Perimeter
Panic
Fire
Gas
Tamper
Duress
Valid or not
when disarm
Invalid
Invalid
Invalid
Valid
Valid
Valid
Valid
Valid
Valid or not
when away
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid or not
when stay
Valid Yes
Invalid Yes
Valid
Valid
Valid
Valid
Valid
Valid
Exit
Delay
No
No
No
No
No
No
Entry Delay
Yes
Yes
No
No
No
No
No
N
o
Sound
and flash
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Mount position
Veranda window
Panic button
Fire detector
Gas detector
Tamper switch
Emergency button
Table 3: Zone Number
Zone Number
1~16/31~46
17
18
19
21~22
30
Bypass or not Type
Applicable Applicable
Applicable
N/A N/A
N/A N/A
Applicable Applicable
Applicable
N/A
N/A
Remark
wireless
panic
duress
fire
wired
panel tamper
/31~46
or detector
Gate
Indoor
Type
number
Default
ON OFF
DC12V
-16-
Figure - -12
Chime Zone
It enables the panel with alarm with entry delay during arm, or issue “ Ding Dong!”under disarm.
Note : The chime zone function only works for entry/exit zone.
-17-
4: Menu System in Detail
Enter Programming
To configure the system, or make any changes to the pre-set functions. During disarm, press “ ” on keypad, Input master code or installer code to enter main menu. Press the to select what users desire to set and confirm with “ # ”. or Press “ to e xit.
“ / ”
Quit Programming
Press “ ” to quit programming to previous menu. Or it will return to previous automatically with no operation within 1 minute.
Programming Items
1. Stop. Comm.
Through this operation, all communication buffers are cleared and all pending messages
are canceled.
2. Zone Bypass
When a zone is bypassed, it is ignored by the system and does not generate an alarm when triggered. It enables users bypass one zone or more zones, or all zones.
To bypass one by one
1. Select “ Bypass one by one ”, press “ # ”.
2. Press “ / ” to select the zone number, ending with “ # ”.
3. And then select “ ON ” or “ OFF ”, ending with “ # ”.
4. Press “ * ” to quit.
To bypass all
Select “ Bypass All ”, press “ # ”. It will remind “ Bypass All ”, press “ # ” to confirm, or press “ * ” to give up
Default installer code: 1234
Default master code: 0808
.
Available with installer code
Available with master code
To set master code
1. From the menu, select “ Co de se t ” , pres , select “ Master code ”, press “ # ”.
s “ # ”
2. Press “ # ” to ed it, I npu t the new master code ending with “ # ”.
3. The LCD will remind if it is edited or not. Press t. “ # ” to confirm. Or “ ” to qui
Note : The default master code is 0808, which is strongly recommended to change after installation.
User Account Naming
Each Code has a user account which can be named within 16 letters. Names can be given either when first adding a code or by editing them later. When the “Enter New Name” screen is displayed the numeric keyboard can be used to enter text. Simply find the corresponding numeric key with the required character and press repeatedly until the wanted character appears .Release the key and the cursor automatically jumps to the next position for users to continue with the next char
acter by
the same method.
The keys have the following functions:
1 # / . 4 ghi
7 pqrs
* Back
Note:
2 abc 5 jkl
8 tuv 0 <space>
Once the name is added, it can be edited but not deleted. If really needed, please delete by initialization.
3 def 6 mno 9 wxyz
Enter
Installer Code
The Installer code grants access to the “ Aided Test ” menu. To set installer code: Same as Master code set.
Note: The default installer code is 1234, which is strongly recommended to edit after installation.
3. Code Set
Code is available as 4-6 digits. If the code is set 5 or 6 digits, the last one cannot be 0. The
code must be different.
Master Code
The Master code is the highest user authorization level. It enables users to enter main menu, which can be edited. With the Master code, users can edit all other user codes except the installer code.
-18- -19-
Temp. Code
The temp. code is just for temporary use which is only valid for 24 hours. It will auto clear and must be reset for next time. Or after initialization or re-power on, it will be cleared.
To edit/delete Temp. code
1. From the menu, select “Code set”, press “#”, select “Temp. code”, press “#”.
2. If any temp. code is se t bef ore , it will display with “ ”, press “#” to edit; If not, the icon
flashes on LCD.
3. Input the new code, Press “#” to confirm. .
4. The LC D wil l remind if it is edited or not. Press any ke y to ex it.
5. The LCD will remind if need change the name. Press “#” to confirm. Or “ ” to quit.
With no code input, press “#” to delete it
Duress Code
While users disarm with duress code, it will indicate “Disarm” on site but will send alarm info. To set duress code: Same as Master code set.
Note: The default duress code is 0809, which is strongly recommended to edit after installation.
User Code 1~4
The user code enables users to arm or disarm. To set/delete user code: Same as “Temp. Code Set”.
4. Phone Set
Phone can be personal phone for voice or for SMS. The system will dial the phone or send SMS when alarm occurs.
Voice phone set
It enables users to edit or delete the number users set before.
To set voice phone
1. Select one telephone group number, press “ #” to set.
2. If any phone is set before, it will display. Press “ # ” to edit. If no phone is set before,
input directly.
3. The phone number can be 16 digits utmost. Press “ # ” to finish. Or if no figure is input, and “ # ” is pressed directly, the number will be deleted.
When users disarm the system with the duress code, the panel doesn’t call the first and second telephone number. And the panel just call the third and fourth telephone number. So we suggest
Note:
that don’t set the third and the fourth telephone number with personal phone number.
SMS Phone
Same as voice phone set.
SMS Option
users can select if SMS message will be sent or not for alarm, arm or disarm to save SMS cost.
To set SMS option:
1. Select the phone group number, press “ # ”to enter.
2. Select parameters users desire to set ending with “ # ”.
3. Select “ O N ” or “ OFF ”.
Panel ID
ID can be set for each control panel so that the Panel can be identified. Different ID must be set for different control panels, which is 4 digits utmost with default as 1234.
Call Attempts
The Call attempts option determines the number of times the system tries to call a telephone number before moving on to the next number in sequence. It will not dial again if it exceeds the attempts. Attempts range can be set 1~30 times.
Ɣ “7” is the factory default.
Ring Attempts
The Ring attempts means the ring times before the phone hangs up. If it is set as “ 0 ”, it means no remote control by call for the system. It can be set from 1 to 9.
Ɣ “6” is the factory default.
GSM Option
It includes SMS Ack, SMS Confirm and SMS Send. If SMS Ack is turned off, then it is not available for control panel. If SMS confirm is turned off, then SMS receipt is not available. If SMS Send is turned off, then SMS Send is not available.
Ɣ On as default.
5. Device Set
For the system to recognize individual devices, each device must be registered. For example, if the device is a wireless transmitter, registration enables the system to identify the source of a received transmission. Each device has an individual ID code. Registering the device to the system familiarizes the system with this code.
WL. Register
There are two ways of register: by code learn or input.
To register by code learn
1. Select the zone number ending with “ # ”. If registered before, it will remind users to re-register. Press “ # ” to continue, or “ * ” to quit. If not registered before, the voice will remind “Start enrolling, transmit now!” with counting down for 60s.
-20-
-21-
2. Trigger the wireless asap to avoid any interference.
3. The system will remind to save after receiving the signal. Press “ # ” to save, or “ * ” to re-register.
During register, if the signal is received for registered code, it will indicate as registered. If the code is in wrong format, it will indicate as wrong. If no code is received within 60s, the system indicate
Note
“Enrolling failed!”.
To register by code input
1. If the code is input before, it will remind if users want to re-register, press “#” to continue, or “ * ”
to exit.
2. Input the ID, ending with “ # ”.
3. The LCD will remind if need change the name. Press “ # ” to confirm. Or “ * ” to quit.
4. Press “ * ” to quit.
Zone Naming
Details refer to the page “User Account Naming”
Clear WL
This enables users to remove the wireless devices by clearance. For the supervision function, If
the device is removed without clearance, the system will remind trouble for device loss.
To Clear WL
1. Select “ Clear WL.”, press “ # ”, select “ Clear single ” or “ Clear All ”.
2. If “Clear single”, select the zone number ending with “#”. While “Clear all” means to clear all
enrolled wireless transmitters.
Set Zone Type
To set zone type
Select “Set zone type”, press “ # ”.
1. Press the navigation key to select the zone users desire to set ending with “ # ”, and then select
the zone type for it ending with “ # ” to save it.
2. Press “ * ” to exit.
Entry Delay
Entry delay means a period for user to enter detection area, activate the delay zone and disarm
before the system alarms. Times can be set from 0 seconds (no delay) up to 300 seconds in 1 second
increments.
Ɣ 100 seconds is the factory default.
Exit Delay
A period for user to leave detecting area once the system armed. Zones with exit delay will not
alarm during this period. Times can be set from 0 seconds (no delay) up to 300 seconds in 1
second increments.
Ɣ 100 seconds is the factory default.
Zone Siren Set
It enables the user to active or mute external siren for some zone.“ ON ” enables the siren to
buzzer during alarm, while “ OFF ” enables the siren dummy. This function is available for
Zones No. 1-16,31-46 (wireless zones), 21-22(wired zones), No.17 and 19.
Chime Zone Set
It is only available for entry/exit zones to enable the “Chime zone Function”. During disarm,
trigger the zone, the voice of “ Ding Dong! ” will be given off.
Wireless Zone Supervision
Wireless devices will transmit supervision signal to the control panel at intervals. If the system
does not receive any signal, then the transmitter is regarded as loss. The max loss period is
called supervision time. If no signal is transmitted during this period, wireless zone trouble
appears in the list of system trouble. Times can be set from 2 hours to 99 hours.
Ɣ 24 hours is the factory default.
Ɣ The period supervision function is closed of all the zones as the factory default.
Max Alarm Times
Users can set one zone with max continuous alarm attempts, default will be 3. After disarm,
the device will restart counting.
Zone Trouble Indication
This option enables users to select whether zone trouble will be indicated in the system trouble
list. If this function is turned off, it will not display.
Keyfob Register
Same as wireless zones, pls refer to that.
Clear Keyfob
-22-
-23-
Same as wireless zones, pls refer to that.
Wireless Siren Register
Same as wireless zones, pls refer to that.
Clear Wireless Siren
Same as wireless zones, pls refer to that.
Activate/Mute Siren
It enables the siren (built-in siren, external wired siren or wireless siren) to be on or off.
Siren Cut-off
Siren cut-off is the period of time the sirens are activated after an alarm has occurred,
which can be set from 0 to 30 minutes.
Call Back When Arm/Disarm
With this function, the siren will beep when users arm or disarm to remind operation success.
1. Press “ / ” to select “ ON ” or “ OFF ”, press “ # ” .
2. Press “ * ” to quit when finished.
Using keyfob to operate the control panel. When arm-away, the built-in siren and wired siren will ring 3 times; when arm-stay, 2 times; when disarm, one sound.
Note
PGM
The PGM is a programmable output that is triggered according to specific system status conditions. The Output Trigger option determines the conditions that activate and deactivate the PGM output.
To trigger PGM output
1. Select “PGM”, press “#”.
2. Press the navigation key to select one of Output trigger and press “ * ” to exit.
PGM only compatible with low voltage(DC) control board. It shall not be connected with
Note
city power(AC) directly.
See following table:
PGM Trigger
Zone 1 Alarm
Zone 2 Alarm
…… ……
Zone 15 Alarm
Zone 16 Alarm
Zone 17 Alarm
Zone 18 Alarm
Zone 19 Alarm
Zone 21 Alarm
Zone 22 Alarm
Zone 30 Alarm
Zone 31 Alarm
Zone 32 Alarm
……
Zone 45 Alarm Zone 46 Alarm
Arm away
Arm Stay
Disarm
Siren follow
Entry/Exit Activate
Active
Perimeter
Panic
Fire
Gas
Tamp er
Duress
Activated by……
Instant Trigger
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
……
See above See above See above See above
Instant Activate
Instant Activate
Instant Activate
Siren follower
See above
See above
See above
See above
See above
See above
See above
Disactivated……
Disarm or PGM cut-off
See above
……
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
……
Any arm status change
Any arm status change
Any arm status change
Siren follower
Until disarm or after PGM cut-off
See above
See above
See above
See above
See above
See above
See above
With all conditions satisfied, PGM will output. The PGM under “arm away, arm stay, disarm or
siren follow ” is not determined by “ PGM cut-off ” time, while PGM under other situations will
switch to disactivated after PGM cut-off. The PGM cut-off can be set by programming.
To set PGM cut-off:
1. Select ಯPGM Cut-off ”, press ಯರ
2. Press ಯರtoeditwithiconindication
3. Enter a PGM cut-off time(0-300s, 000 means continuous activation until disarm)
4. Press ಯರtoexitwhenthedesiredsettingisdisplayed
-24-
-25-
RFID Register
Same as wireless zones, pls refer to that.
Volume
It enables users to activate or mute the speaker and meanwhile adjust the volume.
Clear RFID
Same as wireless zones, pls refer to that.
6. Event Log
This system can save 200 event logs, including alarm and operation issues. When it exceeds 200, it will substitute the earliest event
To query event
1. From the menu, select “ Event log ”, press “ # ” to enter. The earliest event will display.
2. Press “ / ” to query.
3. Press “ * ” to quit when finished.
7. System Option
Set Time/Date
Time and date must be set, or else the event log will be recorded with no time, arm or disarm may not be realized, or system trouble will happen, voice guide will not work.
To set time and date:
1. Input time and date, ending with “ # ”. During input, press “ * ” to quit. When finished, press “#” to confirm. Or if the time is not input completely, but with “ # ” ending. It will indicate “Invalid set!” Then pres “ * ” to re-input.
Auto Arm/Disarm Time
It enables users to set auto arm/disarm time which is set in 24-hr system. Before this, the function of auto arm/disarm must be turned on.
To set auto arm/disarm time
1. Select “ Arm time ” or “ Disarm Time ”, press “ # ” to enter, input time, and press “#” to save.
To turn on/off the function of auto arm/disarm:
1. Select “ Auto ON/OFF ”, press “ # ”.
2. Press “ / ” to select “ON” or “ OFF ”, ending with “ # ”. Press “ * ” to quit when finished.
Note
Time and date must be set, or else the auto arm or disarm function will be recorded with no time. With no time set, auto arm/diarm function may be not available.
Supplementary Entry Delay
The Supplementary Entry Delay is a pre-alarm feature that is employed in the event that the
system is not disarmed during the entry delay. And the period is set as 5s. While this function is
turned off, the system will alarm immediately after entry delay.
Window/Door open remind
This option enables users to turn ON/OFF the function of window/door open remind. The panel
will detect the situation of Magnet and remind users “Door or Window is Open” when users arm
the system. If Zone malfunction is allowed to display, the system will remind and display “system
trouble” . It will disappear after users close the window.
Arm with open Doors
User is allowed to set if the system can be armed while window/door is open. If setting is “ON”,
Arm with open doors is allowed. Otherwise it will be prohibited.
Note
This function only works with “Window / Door open remind” is “ON”.
Initialize All
The Initialization function clears programming of the whole system and restore factory defaults.
8. Aided Test
Siren Test
Siren test is strongly recommended periodic for safety, which includes wired siren, wireless siren and built-in siren. Select the type of siren ending with “ # ” to test. After test, press “ # ” to continue another test. Or “ * ” to finish.
Walk Test
It enables users to make sure if the detectors work normally, which is strongly recommended to do periodically.
To set walk test
1. Select “ Walk test ”, press “ # ”, All registered detectors will display on LCD with the voice guide as “Walk test starts, transmit wireless signal!”
-26- -27-
2. Once the correspondent signal is transmit, the detector display will disappear on LCD. If it will not disappear, it indicates trouble occurs.
3. When all detectors disappear out of LCD, the voice will guide “Walk test over!” meanwhile with “No device!” indicating on LCD.
4. Press “ * ” to quit when test is finished.
Transmitter
It includes TX list (all registered TX and status report), and TX test under this menu. TX test is to test and identify wireless signal. With signal received from registered transmitter, it will display info of it, including ID. With signal received from unregistered transmitter, it will indicate as unknown signal.
To Test TX
1. Select “ Transmitter test ”, press “ # ”, The voice will guide “ Transmitter test starts, transmit wireless signal!”
2. Trigger the transmitter, if it is registered, the info will display on LCD. If it isn't registered, it will indicate as unknown signal.
3. Press “ * ” to quit after test finish.
GSM Test
To ensure the validity of GSM communication, please test the signal network at the installing position.
To test GSM signal
From the menu, select “ 8.Aided Test ”ĺ “ # ” ĺ “ GSM test ” ĺ “ # ”.
Send TEST SMS Interval
The control panel could be set to send a message at the needed time of each week for testing. This testing message will be sent to all the numbers set before.
5: Troubleshooting
“T” will display on LCD if there is. Users can press “ ” to enter the trouble list, and then press
” or “ ” to check. If the trouble is solved, it will disappear out of the list.
Users can clean the display of system trouble remind by disarm the system, but system trouble
information will still be saved in the system trouble list.
If the time is unset, the voice guide of trouble will not sound. System trouble voice indication
will not be available from 10:00PM to 7:00AM. During trouble query, the zone will not alarm
with it trigger.
For detailed system trouble and solution, please refer to following table:
Table 4: Trouble & Solutions
Trouble
Low Battery
Low GSM signal Weak signal of GSM communication, Choose a better position for installation
Low Battery
WL.
Trouble
Transmitter Loss
AC failure
No SIM card
No GSM signal
Time Unset
Commu-
SMS Trouble
nication
Dialling Trouble
Trouble
No call for alarm
The system has no feedback when the zone is triggered
False alarm for wireless zones Abnormal work for
Solutions
Check the power connection timely
Low power of transmitters, Change battery
No signal is received during supervision period, Check if the transmitter is moved or broken
Power is cut off, Check the power connection timely
Loose contact of SIM card, Please re-insert the card after re-powering off the panel
No signal received from mobile phone, SIM card is invalid; Or re-choose a suitable position for installation
Re-set the system time correctly
Failure of SMS send, Check if there is no balance for SIM card
1. Refuse or power off of receiving phone, Pick up the phone in time
2. Overdue of the SIM card, Check if there is no balance for SIM card
Set correct voice telephone number, Set more than two voice telephone numbers.
The zone is bypassed, Un-bypass the zone
When disarm, zone type 1,2,3 do not alarm; arm-stay zone type 2 does not alarm. Operate normally
Different wireless zones use the same code. Delete this wireless zone change the code learn and try again
-28-
-29-
6: Parameters
7: Appendix
General Parameters:
Wirelesszones 32: Wiredzones 2: EOL resistance: 2K~2.4K
Wirelessfrequency 433MHz / 868MHz: Detector / Magnetic contact / Keyfob wireless distance: ı100m (with no obstacle) Sirenwireless distance: ı50m (with no obstacle)
Electric Parameters:
ƽ Power adaptor:Input100V240VAC50/60HZˈOutput12VDC1.5A ƽ Backup battery capacity: ƽ Working voltage: 12VDC ƽ Static current: ƽ AUX power output: AC10-12V, DC6-8V, İ100mA ƽ Siren output: 400mA ƽ PGM output max load: DC 25V/500mA ƽ Built-in siren: 85dB
ƽ Working temperature: -10ഒaഒ
90mA@12V(not including wired detectors and GSM module)
İ
7.2V/800mAh
GSMModule:
ƽ GSMworkingfrequency850/900/1800/1900MHz
ƽ
RX sensitivity:-106dB
ƽ
Current:Standby:25P$RX:P
GG
$
Warranty and Limitations
Although it is an advanced and reliable security system, it does not offer absolute
guaranteed protection against burglary, fire, or other troubles. The limitations are as
follows:
1. Intruders may get access to unprotected openings or have technical sophistication to invalidate the system.
2. The system will disable without power.
3. Alarm warning devices such as bells may not alert people if they are installed in an
improper position. If the alarm bell is installed outside, there are less likely to waken or alert p eople inside th
4. Unsuitable installation position of detectors. If smoke detector is installed in an improper position, it is not easy for smoke to enter the detecting area. Because of doors or walls, it is hard for the detector to detector fires in other rooms, e.g. the detector in the first floor cannot sense fires in the second floor.
5. Lack of maintenance may lead to the system disabled. Weekly testing is necessary to ensur e the system work n ormally.
e bedrooms.
-30-
-31-
Term Definitions
Detector: A facility that detects intrusion and abnormal state automatically via some electric or physical methods and output switch signals or wireless signals to the system for disposal, then output such as infrared detector, smoke detector, etc.
Zone: An area of the detection range of one or group of detectors. Bypass: Close one of the zones temporarily, so that it cannot alarm while act in the zone. Arm Away: The armed status while going out. All the zones without bypass are in ar
status. Arm Stay: Alarm status while you are at home. All the zones are in armed status except
active zones. Disarm: Close the entry/exit zones, active zones, perimeter zones. Other zones are still in
arm status. 24-Hour Zone: No matter armed or disarmed, it is in valid detecting status. It is usually used
in fire alarm, duress alarm and other emergent alarm which can be canceled only by password holder.
Entry Delay: A period for user to enter detection area, activate the de before the system alarms. During the period, user can activate several specified zones (entry zone) without alarm immediately. While exceeding the time, the system alarms if not disarmed. Zones with entry delay are the exit/entry zone and active zone.
Exit Delay A period for user to leave detecting area once the system armed. Zones with exit delay will alarm during this period. The zones with exit delay are the exit/entry zone and the active zone.
Supplementary Entry D
employed in the event that the system is not disarmed during the entry delay. Duress Code: When user is forced to disarm the control panel by burglar, user inputs duress
password, the control panel is disarmed but sends alarm information to the center stations or receiver. The duress password can be used to disarm but set parameters.
Chime Zone: During disarm, while the zone is triggered, the panel will sound “Ding Dong!”
signals,
:
not
med
lay zone and disarm
elay The Supplementary Entry Delay is a pre-alarm feature that is
:
Menu Structure
1. Stop. Comm.
2. Zone Bypass
3. Code Set
4. Phone Set
5. Device Set
6. Event Log
7. System Option
8. Aided Test
#
# #
1. Bypass One By One
2. Bypass All
1. Voice Phone Set
2. SMS Phone Set
3. Panel ID
4. Comm. Option
1. Zone
2. Keyfobs
3. Siren
4. PGM
5. RFID Tag
#
1.Siren Test
2.Walk Test
#
3.Transmitter Test
4.GSM Test
5.SenD TEST SMS Interval
Available with installer code
Available with master code
1. Set Date/Time
2. Auto Arm/Dis. Time
3. Volume
4. Supp.Ent.Delay
5. Window/Door Open Remind
6. Arm With Open Doors
7. Initialize All
-32-
-33-
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
NOTE: This device and its antenna(s) must not be co-located or operation in
conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation. changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
Warning˖
Loading...