Jevi DELTA Series, 3000, 6000, 3000T, 9000T Installation Instruction

...
DELTA FAN HEATERS
MODEL: 3000, 3000T, 6000, 6000T, 9000, 9000T 15000, 15000T, 21000, 21000T
INSTALLATION INSTRUCTION
JEVI A/S | GODTHÅBSVEJ 7 | DK-7100 VE JLE | T: +4 5 75 83 02 11 | F: +45 75 72 29 00 | JEVI@JEVI.DK | WWW.JEVI.COM
A: min. 1500 mm B: min. 2500 mm
Min.
150 mm
A: 372 mm B: 462 mm
A: 300 mm B: 369 mm
A: 435 mm B: 540 mm
A: 410 mm B: 505 mm
A: 322 mm B: 392 mm
A: 420 mm B: 510 mm
Fig. A: Distance at wall mounting Fig. B: 15° wall mounting
A: 3-9 kW B: 15-21 kW
A:
B:
Fig. C: Disassembly
Fig. C
Fan Heaters
Warning
Parts of the fan housing become hot during use. The fan heater must not be installed beneath electrical switches and sockets.
This appliance is not intended for use by per­sons (including children) with reduced physi­cal, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concern­ing use of the appliance by a person responsi­ble for their safety. Children should be supervised to ensure that they do not play with the appliance. Children of less than 3 years should be kept away unless continuously supervised. Children ages from 3 years and less than 8
years shall only switch on/o󰀨 the appliance
provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruc­tion concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION
Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
Do not use the fan heater near bath tubs, cabinet showers, wash basins or swimming
pools. Concerning use of xed fan heaters
which may be used in bathrooms, the fan heater must be installed thus power switch and other controls cannot be reached from the bath tub or cabinet shower. The fan heaters must not be placed near inammable ob­jects. The distances are min. distances. The fan heater must not be covered during use
because of re risk.
Portable fan heaters are only suitable for well­insulated spaces or occasional use.
DELTA 3000, 3000T, 6000, 6000T, 9000, 9000T (A)
These fan heaters are suitable for xed and
portable use. The heaters are splash proof and can be used in dry and humid rooms.
Overheating Protection for A
The fan heaters have a safety cutout which disconnects the supply if the motor fails or if overheating occurs. After cooling down the fan heater, reset can be done with a screwdriver through the hole in the instrument panel. If the fan heater does not start after re-connection you should contact an electrician.
DELTA 15000, 15000T (B)
DELTA fan heaters are suitable for port­able use or can be installed permanently at a height of at least 1.8 metres. The heaters are splash proof and can be used in dry and humid rooms.
DELTA 21000, 21000T (B)
Must only be used as xed fan heater and
installed at a height of at least 1.8 metres. This
fan heater is delivered with wall mounting x
and without plug for the cable.
Overheating Protection for B
The fan heaters have a safety cutout which disconnects the supply if the motor fails or if overheating occurs. If the fan heater does not start after re-connection you should contact an electrician.
NB: See g. C for disassembly of the housing.
General for A + B
Permanent Installation (xed)
The heater can be installed horizontally or at a downward gradient of 15°.
1. The xings are attached to the housing by
use of 4 screws. The two spacing washers are placed between the housing and tubular frame (in the bottom hole).
2. Mark the hole positions. Drill out 4 holes to
attach the xing to the wall. Use M8 screws.
3. Now x the heater in the top screws and
attach the bottom screws.
Use of DELTA - List of signs
O󰀨
Fan on
Half fan and half heat
Full fan and half heat
Full fan and full heat
DELTA fan heaters require no maintenance. However, it is recommended to clean the fan heater of dust by means of compressed air after long time of use or after use in dusty rooms.
Timer
To set time delay rotate the knob clockwise and then turn back anticlockwise to required setting.
Electrical Installation
Installation must be carried out with a multipoled contact breaker with a contact space measuring at least 3 mm per pole. Per­manent installation must always be performed by an authorised electrician in accordance with current regulations. Only the electrician has knowledge of current regulations. The terminals are accessible if the screws and the plate on the right side are removed.
Preservation and storage
The units must be stored under the following conditions:
relative humidity < = 60%
temperature > = 15°C
Disposal Instruction
Equipment containing electrical components may not be disposed of with household waste. It must be collected separately alon with other electrical or electronic waste, as required by local law.
Fan Heaters
EU-DECLARATION OF CONFORMITY
We
JEVI A/S Godthåbsvej 7 DK-7100 Vejle T: +45 75 83 02 11 jevi@jevi.dk www.jevi.dk
Declares under our sole responsibility that the following products;
Type Voltage
[V]
Max. power 3 steps [kW]
DELTA 3kW
1X110 1X230 3X400 3X440 3X480 3X690 3
DELTA 6kW
3X400 3X440 3X480 3X690 6
DELTA 9kW
3X400 3X440 3X480 3X690 9
DELTA 15kW
3X400 3X440 3X480 3X690 15
DELTA 21kW
3X400 3X440 3X480 3X690 21
are in conformity with the following directive(s), standard(s) or other normative document(s):
Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
EN 60335-1:2012 Household and similar electrical appliances - Safety - Part 1:
General requirements
EN 60335-2-30:2009 Household and similar electrical appliances - Safety - Part 2-30:
Particular requirements for room heaters
EN 60204-1:2006 Safety of machinery – Electrical equipment of machines – Part1:
General requirements
EN 62233:2008 Measurement methods for electromagnetic fields of household
appliances and similar apparatus with regard to human exposure
Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC
IEC/EN 61000-6-2:2006 Electromagnetic compatibility (EMC) - Part 6-2: Generic
standards - Immunity for industrial environments
IEC/EN 61000-6-4:2007 Electromagnetic compatibility (EMC) - Part 6-4: Generic
standards - Emission standard for industrial environments + A1:2011
Directive 2011/65/EU RoHS of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
EN 50581:2012 Technical documentation for the assessment of electrical and
electronic products with respect to the restriction of hazardous substances
It remains the responsibility of the end user to install and operate the appliance according to the rules and regulations that are applicable.
Title: Technical Manager
Name: Jan Thomsen Company: JEVI A/S
Date: 01-04-2016 Sign. _______________________________________
Loading...