JETI model MUI EX, MUI 30, MUI 50, MUI 75, MUI 150 Operation Manual

...
Sensor MUI EX
-1-
Assignment of the MUI sensor is measurement of voltage, current and consumed capacity of flight batteries in the model. The wireless data transmission by the DUPLEX 2,4GHz system is monitored by the JETIBOX terminal. For communication purposes the Duplex system takes advantage of the 2,4 GHz band, which besides sending remote control data to the model also receives data from the model back to the transmitter. During flight obtained telemetric data are transmitted in real time and the actual values of the measured data can be displayed on the JETIBOX LCD. Telemetric MUI sensors execute voltage and current measurements in your model and transmit these informations with the aid of the DUPLEX system (receivers and transmitter modules). Thanks to exact current measurements these sensors render it possible to trace the spent capacity of the measured battery. The MUI unit is recording the spent current flow time and its average as well as maximum value. Furthermore it offers exact voltage measurements and recordings of voltage minimum and maximum values. The task of parameter adjustment and measured data setup is performed by the well known alround talent – the JETIBOX terminal. MUI sensors allow setting of acoustical signals in order to announce violation of set parameters. Such alarms may be set for measurements of maximum current and minimum voltage as well as for a maximum of consumed battery capacity. The sound signal is generated by a siren integrated in the transmitter module. For better differentiation are the particular alarms distinguished by Morse alphabetic letters. The acoustical alarm generation in case of parameter violation is working even if the JETIBOX is not connected. With the JETIBOX in place the LCD display shows which parameter has been violated. In case of violation of several parameters the alerts alter consecutively as well as the indications on the LCD display.
Technické parametry
MUI 30
MUI 50
MUI 75
MUI 150
MUI200
Dimensions [mm]
20 x 16,5 x 5
27 x 19 x 11
27 x 19 x 11
27 x 19 x 11
27x19x11
Weight
10 g
19 g
21 g
25 g
30g
Range of measured voltage
0 – 60 V
Range of measured current
0 – 30 A
0 – 50 A
0 – 75 A
0 – 150 A
0 – 200 A
Accuracy of voltage measurment
0,1 %
Accuracy of current measurment
1 %
Operation temperature
- 10 to + 85° C
Supply voltage
5 – 8,4V
Sensor internal consumption
24 mA
32 mA
32 mA
32 mA
32mA
Menu of the telemetric MUI Sensor
Take advantage of the JETIBOX for parameter adjustment and data readout. After connection to the MUI sensor the sensor identification is shown and in the second line the preadjusted actual measured data. By long pushing down button R (right) a fast deletion of all measured parameters can be triggered (min. and max. voltage, max. current, average current, runtime, capacity). Fast deletion is indicated in the first line of the display by an asterix „*“.
By pushing the push button D (downward arrow) of the JETIBOX you will enter the MUI sensor menu.
MUI MENU: Actual Value – by pushing D (downward arrow) you will select the display of actual measured values Volt / Current – displays actual measured voltage and the current passing through the sensor. By simultaneously pushing arrows R and L (right and left) the zero value of the sensor current is calibrated. To the actual measured current value the zero current display is added, i. e. the so called zero shift.
Capacity – shows the actual consumed capacity Run Time – shows the total time of current passage through the sensor. Included is also the time when the current has exceeded the adjusted current value Start Trigger in the Setting menu.
Sensor MUI EX
-2-
MUI MENU: MIN / MAX – by pushing the button D (downward arrow) you will select the display of extreme voltage and current value recordings which occurred during the measurement. The extreme recordings are deleted automatically or they can be deleted in the menu Setting - Erase Data. Automatic deletion occurs when the MUI sensor has just been connected to the voltage supply and the current, as set in the menu Setting-Start Trigger, will be exceeded. If after connection of the sensor the set current will not be exceeded, values of the previous sensor operation will be displayed.
U MIN / MAX – shows the minimum and maximum value of the measured voltage I AVG / MAX – shows the average value of the measured current and its maximum
MUI MENU: Setting – by pushing the button D (downward arrow) you will enter the basic sensor setup menu Start Trigger setup of a current value, at which after sensor connection recording of values like minimum, maximum and current transit time starts. If the adjusted value is 0 A, values will be recorded immediately after connection of the sensor to its power supply and data read out of the previous operation will not be possible. Erase Data by pushing arrows R and L (right and left) simultaneously the records of measured parameters will be deleted First Parametr adjustment of the display of the first parameter in the JETIBOX LCD, which is shown in the second line of the basic sensor menu (the first line shows the identification, for instance SENSOR MUI 30) Second Parametr - adjustment of the display of the second parameter in the JETIBOX LCD, which is shown in the second line of the basic sensor menu (the first line shows the identification, for instance SENSOR MUI 30) Auto. Erase - This function of automatical deletion after overstepping the trigger level can be activated or deactivated.
MUI MENU: ALARMS – by pushing button D (downward arrow) you enter setup of particular alarms. If one of the adjusted parameters becomes exceeded, the JETIBOX LCD will in the second line of the basic menu alternately show the original display with the pertinent alarm and the transmitter module siren will emit an acoustical alarm. The first tone is a revelation signal and the second one is signalling a Morse Code character of the relevant alarm. If the alarm is set to OFF, this kind of alarm will be switched off. Voltage alarm (alarm U ..- ) adjustment of the value of voltage signalling, if the measured voltage decreases beyond the set value, the voltage alarm U will be activated. Current alarm – (alarm I .. ) adjustment of the value of current signalling, if the measured current increases beyond the set value, the current alarm I will be activated. Capacity alarm (alarm C -.-. ) adjustment of the signalling value of consumed capacity , if the adjusted value of maximum consumed capacity is exceeded, alarm C will be activated.
MUI MENU: SERVICE – by pressing button D (arrow down) you will change to depiction of the firmware version and to renewal of the sensor default setting. Factory Defaults by simultaneous pressing of arrows R and L (right and left) the factory settings of the MUI are loaded. MUI v. xx.xx ID xxxxx:xxxxx product marking with firmware version and series number (ID).
Particular phases of current measurements
A – when after switching on of the sensor the
current did not exceed the set value Start Trigger. Measured values (U MIN / MAX, I AVG / MAX, Capacity, Run Time) correspond with measured values of the previous operation. B the value Start Trigger has been exceeded. Previous measured values (U MIN / MAX, I AVG / MAX, Capacity, Run Time) will be deleted and
actualized by the actual measurement course.