1. Introduction 
The Expander SW4 is an extension for magnetic and RC switches and is designed for switching 
multiple devices simultaneously. The JETI model company produces a wide range of devices that can 
be switched by magnetic switch or RC switch. The Expander SW4 allows you to combine the switching 
duties so that several devices can be controlled using one only element. Furthermore, some outputs are 
optically isolated to prevent interference. This makes it is possible to isolate control of devices which 
may be sensitive to electric interference. 
2. Switch Expander circuitry 
Expander SW4 has on output for a magnetic or RC switch and 4 outputs, 3 of them are optically 
isolated (OPTO1-OPTO3). The output that is not optically isolated is connected to the magnetic or RC 
switch directly, including the power supply (Master input). The optically isolated outputs must be 
powered separately. One of the optically isolated outputs is inverted (e.g. for SBEC40) – OPT INV. 

Návod k obsluze: Switch Expander 
-3- 
Fig. 1: Expander SW4 application connection 
Circuitry with the RC Switch – in case its setting has been changed in the transmitter, it is necessary  
to make sure that the switch is set to normal output (as by default). If the output is set to inverted, the 
Expander SW4 would not work correctly. The RC switch is connected to the Expander SW4 output 
labelled Switch, see Fig. 1. 
Circuitry with the magnetic switch – normal output of the magnetic switch is connected to the input  
of the Expander SW4 (labelled Switch), see Fig. 1. 
If an optical connection is needed, the –poles of the separated circuits must not be connected 
anywhere, as well as the +poles. 
Magnetic or RC switches, as well as the Expander SW4, are supplied power from the same Master 
output. Thus it is necessary to have the power supply connected at least to this connector, see Fig. 1. 
If the power supply of the Expander SW4 is interrupted when the magnetic or RC switch is on, 
the devices connected to any optically isolated output are switched OFF!! If only a magnetic or 
RC switch is disconnected from the Expander SW4, all the devices connected to Expander SW4 
outputs remain switched ON. 
Please follow all the directives described in individual manuals for the magnetic or RC switch! 

Návod k obsluze: Switch Expander 
-4- 
3. Installation 
The Expander SW4 can be mounted to the model using adhesive Velcro. It is very important to 
prevent the cable connected to the Master output from disconnecting. 
4. Technical specifications of Expander SW4 
3,5 – 59 V (up to 15Lixx) 
Current consumption in switched-off state 
5. Warranty 
For this product JETI model grants a warranty of 24 months from the day of purchase under the 
assumption that it has been operated in conformity with these instructions at recommended voltages 
and that it has not been damaged mechanically. Warranty and post warranty service is provided first 
by your JETI dealer and alternately by the manufacturer. 
We wish you successful flying with the products of JETI model s.r.o. Příbor, www.jetimodel.cz