Jensen Transformers PO-2XX Data Sheet

Jensen...The Worlds Finest Audio Transformers
Connector options
Dimensions
PO-2XX Two channel output ground isolator
• Drives balanced and unbalanced signals long distances
• Withstands input levels in excess of +26 dB at 30 Hz
• Plug & play easy to use, no power required
The Iso•Max PO-2XX is a two-channel line output isolator for both balanced and unbalanced signals where extreme signal handling is required to drive long cable runs.
The design begins with a rugged anged enclosure that comes standard with gold plated XLRs and a removable screw-down barrier strip for easy in­stallation in NEMA enclosures. Plug and play easy to use, this passive inter­face does not require any power to work. Inside are two high performance nickel core Jensen transformers that are able to withstand signals in excess of +26 dB without discernible distortion while delivering a linear response to 150 kHz. This provides galvanic isolation between the input and output to eliminate hum and buzz caused by ground loops, rejecting noise by as much as 110 dB. To further optimize the performance, a bottom mounted eight position ‘set & forget’ dip switch enables the user to congure the PO­2XX grounding scheme as needed.
PO-2XX
( FRONT )
( BOTTOM )
( TOP )
( REAR )
CH 1
IN
INTERNAL SCHEMATIC
ON THIS LABEL
1.25”
(31.8mm)
REMOVABLE BARRIER STRIP
CH 2
JENSEN TRANSFORMERS, INC.
OUT
(176.3mm)
18
(165.1mm)
INOUT
IN
6.94”
6.50”
CH 1
CH 2
INOUT
OUT
3.00”
(76.2mm)
.695”
(17.6mm)
3.50”
(88.9mm)
1.71”
(43.4mm)
Made to accommodate both balanced or unbalanced signals, simply con­nect the PO-2XX anywhere you like between the source and destination and the PO-2XX will quietly go to work as it delivers exceptional audio while eliminating ground loops and electromagnetic interference (EMI). This makes the Iso•Max PO-2XX a superb choice for the most demanding studio, broadcast and performance venue installations.
Applications
LONG CABLE
PO-2XX with a PA system
Eliminating noise in a PA system can sometimes take hours of trouble shoot­ing, particularly when the mixer, ampliers and speakers are distanced apart. Simply connect the PO-2XX at the output of your mixer to instantly eliminate hum and buzz caused by ground loops.
Isolating one console from the other
Whether you are isolating two consoles in a festival or experiencing noise when connecting to a drive rack, the PO-2XX is easily inserted into the signal chain to break the ground loop and eliminate noise as it easily handles huge bass transients without distortion.
The PO-2XX comes standard with XLR inputs and outputs. It is also available special order with the following connector congurations for use with both balanced and unbalanced systems.
PO - 2XX
XLR-F IN, XLR-M OUT XLR-F IN, BNC OUT
PO - 2XN
XLR-F IN, WIRE LEAD OUT XLR-F IN, 1/4” TRS OUT
PO - 2XR
XLR-F IN, RCA OUT 1/4” TRS IN / OUT
PO - 2NN
WIRE LEAD IN / OUT RCA IN, WIRE LEAD OUT
PO - 2RR
RCA IN / OUT RCA IN, XLR-M OUT
PO - 2XB
PO - 2XP
PO - 2PP
PO - 2RN
PO - 2RX
Jensen Transformers Inc., 9304 Deering Ave. Chatsworth, CA 91311 P: (818) 374-5857 F: (818) 374-5856 info@jensen-transformers.com
jensen-transformers.com
Jensen...The Worlds Finest Audio Transformers
PO-2XX
THD at FIXED INPUT LEVELS, Rs=0
THD+N (%) vs FREQUENCY (Hz) 20 Hz DISTORTION AT FIXED Rs
THD+N (%) vs OUTPUT LEVEL (dBU)
1.01.0
+23 dBu
0.1
0.1
600 Ω
150 Ω
0.01
+14 dBu
0.01
0 Ω
+4 dBu
0.001
200 2K 20K
0.001
-40 -30 -20 -10 -0 +10 +20 +3020
REFERENCE LEVEL RESPONSE AMPLITUDE (dB) vs FREQUENCY (Hz) DEVIATION (Deg) vs FREQUENCY (Hz)DEVIATION FROM LINEAR PHASE
+1
REF
+5
+4
+3
-1
-2
+2
+1
0
-3
-4
-5
Low frequency data augmented with use of Hewlett-Packard 332A Frequency Synthesizer
-6
20m 200m 2 2020 200200 2K2k 20K
PARAMETER CONDITIONS MINIMUM TYPICAL MAXIMUM
Input impedance, Zi
Voltage gain 1 kHz, 0 dBu, test circuit 1, Rs = 0 Ω
Magnitude response, ref 1 kHz
Deviation from linear phase (DLP) 20 Hz to 20 kHz, 0 dBu, test circuit 1, Rs = 0 Ω +0.3 / -0° ±1.0°
Distortion (THD)
Maximum output level
Common - mode rejection ratio (CMRR)
Recommended source impedance output impedance of device connected the ISO-MAX input 0 600 Ω 2 kΩ
Recommended load impedance input impedance of device connected the ISO-MAX output 150 Ω 20 kΩ
Output impedance, Zo 20 Hz to 20 kHz, 0dBu, test circuit 4 80 Ω
Optimal cable length (balanced)
Optimal cable length (unbalanced)
Temperature range operation or storage 0°C 70°C
Input to Output Voltage Difference* any input to any output shield or any shield to case, 60 Hz
All levels are output unless noted
* IMPORTANT NOTE: THIS PRODUCT IS NOT INTENDED FOR USE IN CIRCUMSTANCES WHERE THE DC OR PEAK AC VOLTAGE BETWEEN INPUT AND OUTPUT CONNECTIONS EXCEEDS 34 VOLTS OR WHERE ITS FAILURE COULD CAUSE INJURY OR DEATH.
20 Hz to 20 kHz, 0 dBu, test circuit 3, RL = 600 Ω 670 Ω 680 Ω 690 Ω
1 kHz, 0 dBu, test circuit 3, R
20 Hz, 0 dBu, test circuit 1, Rs = 0 Ω -0.1 dB -0.02 dB ±0.0 dB
20 kHz, 0 dBu, test circuit 1, Rs = 0 Ω -0.1 dB ±0.0 dB +0.1 dB
1 kHz, +4 dBu, test circuit 1, Rs = 0 Ω <0.001%
20 Hz, +4 dBu, test circuit 1, Rs = 0 Ω 0.004% 0.03%
20 Hz, 1% THD, test circuit 1, Rs = 0 Ω +20 dBu +22 dBu
60 Hz, test circuit 2 110 dB
3 kHz, test circuit 2 75 dB 85 dB
input 50 m (150’) 200 m (600’)
output 100 m (300’) 300 m (1000’)
input 8 m (25’) 15 m (50’)
output No limitations
20K 200K
= 20 kΩ
L
-1
-2
-3
-4
-5
-1.2 dB
-1.1 dB -0.9 dB
24 V RMS 34 V peak
Test Circuit 1:
Test Circuit 2:
Test Circuit 3:
All minimum and maximum specica­tions are guaranteed. Unless noted otherwise, all specications apply at 25
°C. Specications subject to change
without notice. All information herein is believed to be accurate and reliable, however no responsibility is assumed for its use nor for any infringements of patents which may result from its use. No license is granted by implication or otherwise under any patent or patent
rights of Jensen Transformers, Inc.
Jensen Transformers Inc., 9304 Deering Ave. Chatsworth, CA 91311 P: (818) 374-5857 F: (818) 374-5856 info@jensen-transformers.com
jensen-transformers.com