Jensen Transformers JT-MB-C-JENSEN Specifications

MICROPHONE BRIDGING TRANSFORMER
DUAL FARADAY SHIELDS FOR HIGH ISOLATION
M Provides additional, isolated balanced output as mic "splitter" M Solves "transformerless" preamp problems when used as retrofit M High common-mode rejection: 130 dB at 60 Hz M Excellent frequency response and time domain performance M Low insertion loss: 0.8 dB
This transformer is designed to be driven from a 150 S microphone source and loaded by the typical 1 kS input impedance of microphone preamplifiers. It can be used with balanced or unbalanced sources and/or loads since both primary and secondary are fully balanced. A 30 dB magnetic shield package is standard.
JT-MB-C
TYPICAL APPLICATION
JT-MB-C SPECIFICATIONS (all levels are input unless noted)
PARAMETER CONDITIONS MINIMUM TYPICAL MAXIMUM
Input impedance, Zi 1 kHz, !20 dBu, test circuit 1 1.00 kS 1.06 kS 1.15 kS
Voltage gain 1 kHz, !20 dBu, test circuit 1 !0.90 dB !0.82 dB !0.70 dB
Magnitude response, ref 1 kHz
Deviation from linear phase (DLP) 20 Hz to 20 kHz, !20 dBu, test circuit 1 +3.3/!0E ±5.0E
Distortion (THD)
Maximum 20 Hz input level 1% THD, test circuit 1 0 dBu +2.0 dBu
Common-mode rejection ratio (CMRR) 150 S balanced source
Common-mode rejection ratio (CMRR) 150 S unbalanced source
Output impedance, Zo 1 kHz, test circuit 1 245 S
DC resistances
Capacitances @ 1 kHz
Turns ratio 1:0.999 1:1.000 1:1.001
Temperature range operation or storage 0E C70E C
Breakdown voltage (see IMPORTANT NOTE below)
20 Hz, !20 dBu, test circuit 1 !0.50 dB !0.14 dB ±0.0 dB
20 kHz, !20 dBu, test circuit 1 !0.25 dB !0.13 dB +0.1 dB
1 kHz, !20 dBu, test circuit 1 0.001%
20 Hz, !20 dBu, test circuit 1 0.05% 0.15%
60 Hz, test circuit 2 130 dB
3 kHz, test circuit 2 80 dB 95 dB
60 Hz, test circuit 3 115 dB
3 kHz, test circuit 3 80 dB
primary (RED to BRN) 48 S
secondary (YEL to ORG) 50 S
primary to shield and case 54 pF
secondary to shield and case 67 pF
primary or secondary to shield and case, 60 Hz, 1 minute test duration
250 V RMS
All minimum and maximum specifications are guaranteed.
without notice. All information herein is believed to be accurate and reliable, however no responsibility is assumed for its use nor for any infringements of patents which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Jensen Transformers, Inc.
IMPORTANT NOTE
breakdown voltage specification is intended to insure integrity of internal insulation systems; continuous operation at these voltages is NOT recommended. Consult our applications engineering department if you have special requirements.
: This device is NOT intended for use in life support systems or any application where its failure could cause injury or death. The
Unless noted otherwise, all specifications apply at 25EC. Specifications subject to change
JENSEN TRANSFORMERS, INC., 7135 Hayvenhurst Avenue, Van Nuys, CA 91406-3807, USA
9/01
(818) 374-5857 • FAX (818) 374-5856 • www.jensen-transformers.com