Jensen Transformers JT-11SSP-6M Specifications

LINE INPUT TRANSFORMER
1:1 SPLIT WINDING "REPEAT COIL"
M Ideal for use with low input impedance circuits M Wide bandwidth: !!!!3 dB at 0.4 Hz and 220 kHz M Recommended for levels up to +19 dBu at 20 Hz M Insertion loss only 1.9 dB in 600 SSSS to 600 SSSS application M High common-mode rejection: 110 dB at 60 Hz
This transformer has split primary and secondary windings which can be connected for either 1:2 (150:600 S), 1:1 (600:600 S), or 2:1 (600:150 S) operation. Distortion, although specified for 600 S sources, will be further reduced by lower impedances. A 30 dB magnetic shield package is standard.
JT-11SSP-6M
1:1 CONFIGURATION
TYPICAL APPLICATION
JT-11SSP-6M SPECIFICATIONS (1:1 series/series configuration, all levels are input unless noted)
PARAMETER CONDITIONS MINIMUM TYPICAL MAXIMUM
Input impedance, Zi 1 kHz, +4 dBu, test circuit 1 738 S 745 S 752 S
Voltage gain 1 kHz, +4 dBu, test circuit 1 !2.1 dB !1.9 dB !1.7 dB
Magnitude response, ref 1 kHz
Deviation from linear phase (DLP) 20 Hz to 20 kHz, +4 dBu, test circuit 1, Rs=600 S +0.6/!0E ±2.0E
Distortion (THD)
Maximum 20 Hz input level 1% THD, test circuit 1, Rs=600 S +17 dBu +19 dBu
Input Common-mode rejection (CMRR) 600 S balanced source
Output Common-mode rejection (CMRR) 600 S balanced load
Output impedance, Zo 1 kHz, test circuit 1, Rs=600 S 745 S
DC resistances
Capacitances @ 1 kHz
Turns ratio any winding to any other winding 0.999:1 1.000:1 1.001:1
Temperature range operation or storage 0E C70E C
Breakdown voltage (see IMPORTANT NOTE below)
20 Hz, +4 dBu, test circuit 1, Rs=600 S !0.2 dB !0.05 dB ±0.0 dB
20 kHz, +4 dBu, test circuit 1, Rs=600 S !0.1 dB !0.01 dB +0.1 dB
1 kHz, +4 dBu, test circuit 1, Rs=600 S <0.001%
20 Hz, +4 dBu, test circuit 1, Rs=600 S 0.04% 0.10%
60 Hz, test circuit 2 110 dB
3 kHz, test circuit 2 60 dB 75 dB
60 Hz, test circuit 3 79 dB
3 kHz, test circuit 3 45 dB
total primary (RED to ORG) 32 S
total secondary (GRY to GRN) 113 S
total primary to shield and case 950 pF
total secondary to shield and case 1.22 nF
primary or secondary to shield and case, 60 Hz, 1 minute test duration
250 V RMS
All minimum and maximum specifications are guaranteed.
without notice. All information herein is believed to be accurate and reliable, however no responsibility is assumed for its use nor for any infringements of patents which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Jensen Transformers, Inc.
IMPORTANT NOTE
breakdown voltage specification is intended to insure integrity of internal insulation systems; continuous operation at these voltages is NOT recommended. Consult our applications engineering department if you have special requirements.
: This device is NOT intended for use in life support systems or any application where its failure could cause injury or death. The
Unless noted otherwise, all specifications apply at 25EC. Specifications subject to change
JENSEN TRANSFORMERS, INC., 7135 Hayvenhurst Avenue, Van Nuys, CA 91406-3807, USA
9/01
(818) 374-5857 • FAX (818) 374-5856 • www.jensen-transformers.com