Jensen Transformers DIN-PC Data Sheet

Jensen...The Worlds Finest Audio Transformers
Module Schematic Diagram
Pro-balanced signal to hi-
The Iso•Max DIN-PC is perfect for situa- tions where you need to send a pro-bal- anced signal to a stereo hi- type input. Simply connect to the balanced inputs and output the -10 dB signal to feed the hi- system.
Dimensions
DIN-PC Pro-to-consumer isolator
• Eliminates hum and buzz caused by ground loops
• Ruler at frequency response from 10 Hz to 140 kHz
• Plug and play easy to use, no power required
DIN-PC
Order #: J400-0024
( TOP VIEW ) ( SIDE VIEW )
2.30”
(58.4 mm)
1.90”
(48.3 mm)
1.33”
(33.8 mm)
The Iso•Max DIN-PC is a single channel pro-to-consumer isola­tor that is used to convert a +4 dBu line-level device to -10 dBV for consumer-level signals such as connecting the balanced output from a mixing desk to the unbalanced input of a hand­held video recorder or laptop.
The design begins with a gray molded assembly made from UL94-VO ame retardant Noryl that snaps into place onto a standard 35 mm DIN rail for easy installation in a NEMA enclosure. Connections to and from the module are made via removable screw-down wire terminals. Plug and play easy to use, this passive interface does not require any power to work. Inside is a Jensen high performance transformer that is able to withstand signal levels to +21 dBu at 20 Hz without dis­cernible distortion. This provides galvanic isolation between the input and output to eliminate hum and buzz caused by ground loops, rejecting noise by as much as 120 dB.
Made for the most demanding professionals, the DIN-PC delivers a ruler at response from 10 Hz to 140 kHz with less than 2° phase shift at all frequencies. This makes the DIN-PC ideal for converting balanced sources to unbalanced inputs for large scale installations in performance venues, broadcast houses and AV systems.
3.85”
(97.8 mm)
1.42”
(63.0 mm)
0.0”
(00 mm)
1.78”
(45.2 mm)
( END VIEW )
2.43”
(61.7 mm)
Applications
DIN-PC with a laptop
Use the DIN-PC to convert the balanced line level output from your mixing console to the unbalanced input on your laptop or sound card. The DIN-PC will manage the signal while eliminating hum and buzz caused by ground loops.
Jensen Transformers Inc., 9304 Deering Ave. Chatsworth, CA 91311 P: (818) 374-5857 F: (818) 374-5856 info@jensen-transformers.com
Audio interface for video camera
Capturing a live performance is easy using the DIN-PC as the audio interface between the mixing console and your video camera. Connect the console to the balanced inputs and send the unbal­anced outputs to your camera.
jensen-transformers.com
Jensen...The Worlds Finest Audio Transformers
DIN-PC
Order #: J400-0024
THD at FIXED INPUT LEVELS
THD+N (%) vs FREQUENCY (Hz) DISTORTION at FIXED FREQUENCIES
THD+N (%) vs INPUT LEVEL (dBU)
1.01.0
+20 dBu
0.1
0.1
20Hz
+14 dBu
0.01
0.01
30Hz
+4 dBu
50Hz
0.001 200
2K 20K -15-20 -10 -5 -0 +5 +10 +15 +20
0.001
-30 -2520
REFERENCE LEVEL RESPONSE AMPLITUDE (dB) vs FREQUENCY (Hz) DEVIATION (Deg) vs FREQUENCY (Hz)DEVIATION FROM LINEAR PHASE
+1
REF
+5
+4
+3
-1
-2
+2
+1
0
-3
-4
-5
Low frequency data augmented with use of Hewlett-Packard 3325A Frequency Synthesizer
-1
-2
-3
-4
-6
0.2 2 20 20200 2002K 2K20K 20K
200K
-5
PARAMETER CONDITIONS MINIMUM TYPICAL MAXIMUM
Input impedance, Zi
Voltage gain 1 kHz, +4 dBu, test circuit 1
Magnitude response, ref 1 kHz
Deviation from linear phase (DLP) 20 Hz to 20 kHz, +4 dBu, test circuit 1 +0.6/-0.1° ±2.0°
Distortion (THD)
Maximum 20 Hz input level 1% THD, test circuit 1 +19 dBu +21 dBu
Common mode rejection ratio (CMRR)
50 Ω balanced source
Common mode rejection ratio (CMRR)
600 Ω unbalanced source
Output impedance, Zo 1 kHz, test circuit 1 225 Ω
Optimal cable length
Temperature range operation or storage 0°C 70°C
Breakdown voltage*
All levels are input unless noted
* IMPORTANT NOTE: THIS PRODUCT IS NOT INTENDED FOR USE IN CIRCUMSTANCES WHERE THE DC OR PEAK AC VOLTAGE BETWEEN INPUT AND OUTPUT CONNECTIONS EXCEEDS 34 VOLTS OR WHERE ITS FAILURE COULD CAUSE INJURY OR DEATH.
1 kHz, +4 dBu, test circuit 1 39.4 kΩ 41.5 kΩ 43.6 kΩ
-13.4 dB
20 Hz, +4 dBu, test circuit 1 -0.15 dB -0.04 dB ±0.0 dB
20 kHz, +4 dBu, test circuit 1 -0.15 dB -0.03 dB +0.1 dB
1 kHz, +4 dBu, test circuit 1 <0.001%
20 Hz, +4 dBu, test circuit 1 0.015% 0.05%
60 Hz, test circuit 2 120 dB
3 kHz, test circuit 2 70 dB 85 dB
60 Hz, test circuit 3 90 dB
3 kHz, test circuit 3 55 dB
output 1 m (3’) 6 m (20’)
primary to secondary to shield and case, 60 Hz, 1 minute test duration
250 V RMS
-12.9 dB -12.4 dB
Test Circuit 1:
Test Circuit 2:
Test Circuit 3:
All minimum and maximum specications are guaranteed. Unless noted otherwise, all specications apply at 25°C. Specica­tions subject to change without notice. All information herein is believed to be accurate and reliable, however no responsibility is as­sumed for its use nor for any infringements of patents which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Jensen Transformers, Inc.
Jensen Transformers Inc., 9304 Deering Ave. Chatsworth, CA 91311 P: (818) 374-5857 F: (818) 374-5856 info@jensen-transformers.com
jensen-transformers.com