LINE INPUT/OUTPUT TRANSFORMER
1:1 SPLIT WINDING "REPEAT COIL"
M Ideal for patch bay applications
M Wide bandwidth: !!!!3 dB at 0.4 Hz and 200 kHz
M Recommended for levels up to +21 dBu at 20 Hz
M Voltage loss only 1.9 dB in 600 SSSS to 600 SSSS application
M High common-mode rejection: 125 dB at 60 Hz
This transformer has split primary and secondary windings which can be
connected for either 1:2 (150:600 S), 1:1 (600:600 S), or 2:1 (600:150 S)
operation. Distortion, although specified for 600 S sources, will be further
reduced by lower impedances.
DIN - PB
MODULE SCHEMATIC DIAGRAM
DIN - PB SPECIFICATIONS (1:1 series/series configuration, all levels are input unless noted)
PARAMETER CONDITIONS MINIMUM TYPICAL MAXIMUM
Input impedance, Zi 1 kHz, +4 dBu, test circuit 4 743
Voltage gain 1 kHz, +4 dBu, test circuit 1
Magnitude response,
ref 1 kHz
Deviation from linear phase (DLP) 20 Hz to 20 kHz, +4 dBu, test circuit 1, Rs=600
Distortion (THD)
Maximum 20 Hz input level 1% THD, test circuit 1, Rs=600
Input Common-mode rejection (CMRR)
600 S balanced source
Output Common-mode rejection (CMRR)
600 S balanced load
Output impedance, Zo 1 kHz, test circuit 5, Rs=600
DC resistances
Capacitances @ 1 kHz
Turns ratio any winding to any other winding 0.999:1 1.000:1 1.001:1
Temperature range operation or storage 0E C70
Breakdown voltage
(see IMPORTANT NOTE below)
20 Hz, +4 dBu, test circuit 1, Rs=600
20 kHz, +4 dBu, test circuit 1, Rs=600
1 kHz, +4 dBu, test circuit 1, Rs=600
20 Hz, +4 dBu, test circuit 1, Rs=600
60 Hz, test circuit 2 125 dB
3 kHz, test circuit 2 75 dB 95 dB
60 Hz, test circuit 3 110 dB
3 kHz, test circuit 3 80 dB
S
total primary, Pin 7 to Pin 8, Pin 4 and Pin 5 shorted 39
total secondary, Pin 11 to Pin 12, Pin 14 and Pin 15 shorted 112
total primary to shield and case 676 pF
total secondary to shield and case 531 pF
primary or secondary to shield and case, 60 Hz,
1 minute test duration
S !
S !
S
S
S
S
S
2.1 dB
!
0.2 dB
0.1 dB
+19 dBu +21 dBu
250 V RMS
750
S
1.9 dB
!
0.06 dB ±0.0 dB
!
0.02 dB +0.1 dB
!
+0.6/!0
<0.001%
0.025% 0.10%
750
S
S
S
757
1.7 dB
!
±2.0
E
S
E
C
E
All minimum and maximum specifications are guaranteed. Unless noted otherwise, all specifications apply at 25EC. Specifications subject to change
without notice. All information herein is believed to be accurate and reliable, however no responsibility is assumed for its use nor for any infringements of
patents which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Jensen Transformers, Inc.
IMPORTANT NOTE: This device is NOT intended for use in life support systems or any application where its failure could cause injury or death. The
breakdown voltage specification is intended to insure integrity of internal insulation systems; continuous operation at these voltages is NOT recommended.
Consult our applications engineering department if you have special requirements.
JENSEN TRANSFORMERS, INC., 7135 Hayvenhurst Avenue, Van Nuys, CA 91406-3807, USA
10/02
(818) 374-5857 • FAX (818) 374-5856 • www.jensen-transformers.com