Jensen Transformers DIN-2LO-11FL User Manual

DUAL LINE OUTPUT MODULE
1:1 BIFILAR WINDINGS
M Distortion 0.035% typ at 20 Hz and +4 dBu output level M Wide bandwidth: !!!!3 dB at 0.2 Hz and 15 MHz M Drives 600 SSSS loads to levels up to +21 dBu at 20 Hz M Excellent time domain performance: DLP 0.3EEEE typ 20 Hz to 20 kHz M Insertion loss only 1.6 dB when driving 600 SSSS load
This module is designed for high performance line output stages. The 50% nickel alloy core gives it excellent distortion and level handling at a cost allowing many applications to enjoy the advantages of an output transformer. Driving signals should be free of DC and source impedance kept as low as possible.
DIN - 2LO - 11FL
MODULE SCHEMATIC DIAGRAM
DIN -2LO -11FL SPECIFICATIONS (all levels are output unless noted)
PARAMETER CONDITIONS MINIMUM TYPICAL MAXIMUM
Input impedance, Zi 20 Hz to 20 kHz, 0 dBu, test circuit 3 705 S 716 S 725 S
Voltage gain 1 kHz, 0 dBu, test circuit 1, Rs=0 S !1.8 dB !1.6 dB !1.4 dB
Magnitude response, ref 1 kHz
Deviation from linear phase (DLP) 20 Hz to 20 kHz, 0 dBu, test circuit 1, Rs=0 S +0.3/!0E ±1.0E
Bandwidth
Distortion (THD)
Maximum output level 20 Hz, 1% THD, test circuit 1, Rs=0 S +19 dBu +21 dBu
Common-mode rejection ratio (CMRR)
Output impedance, Zo 20 Hz to 20 kHz, 0 dBu, test circuit 4 116 S
DC resistance each winding 58 S
Capacitance
Turns ratio 0.999:1 1.000:1 1.001:1
Temperature range operation or storage 0E C70E C
Breakdown voltages 60 Hz, 1 minute test duration (see IMPORTANT NOTE below)
20 Hz, 0 dBu, test circuit 1, Rs=0 S !0.10 dB !0.03 dB ±0.00 dB
20 kHz, 0 dBu, test circuit 1, Rs=0 S !0.10 dB ±0.00 dB +0.10 dB
LF !3 dB re 1 kHz, test circuit 1, Rs=0 S 0.20 Hz
HF !3 dB re 1 kHz, test circuit 1, Rs=0 S 15 MHz
1 kHz, +4 dBu, test circuit 1, Rs=0 S <0.001%
20 Hz, +4 dBu, test circuit 1, Rs=0 S 0.035% 0.15%
60 Hz, test circuit 2 94 dB
3 kHz, test circuit 2 75 dB 83 dB
winding to winding, 1 kHz 24 nF
winding to frame, 1 kHz 35 pF
winding to winding 250 V RMS
winding to frame 500 V RMS
All minimum and maximum specifications are guaranteed. Unless noted otherwise, all specifications apply at 25EC. Specifications subject to change without notice. All information herein is believed to be accurate and reliable, however no responsibility is assumed for its use nor for any infringements of patents which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Jensen Transformers, Inc. IMPORTANT NOTE: This device is NOT intended for use in life support systems or any application where its failure could cause injury or death. The breakdown voltage specification is intended to insure integrity of internal insulation systems; continuous operation at these voltages is NOT recommended. Consult our applications engineering department if you have special requirements.
JENSEN TRANSFORMERS, INC., 7135 Hayvenhurst Avenue, Van Nuys, CA 91406-3807, USA
9/03
(818) 374-5857 • FAX (818) 374-5856www.jensen-transformers.com