www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Downdraft Gas Professional Grill-Range Oven:
SVD8310S
29 15/16"
26 3/8"
• Dimensions (Actual Size) •
Width:
29 15/16"
Depth:
26 3/8"
Height:
Door swing:
Height at full leg adjustment:
Height at 0" leg adjustment:
• Additional Information •
• Units can be installed as a Freestanding unit or
Slide-In unit. Slide-in installation does NOT allow for
use of a backsplash or side panels. If either is desired,
use the free-standing cutout and instructions.
• Units depth including door handle is 28 3/8".
• Electrical requirements: 120/240 VAC or 120/208
VAC, 60Hz. 30 amp minimum required.
• Cabinetry over cooktop : 30' minimum clearance
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet. 24" minimum
when bottom of wood or metal cabinet is protected by
not less than 1/4" flame retardant millboard covered
with not less than no. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or copper.
• To eliminate the hazard of reaching over heated
surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage
is to be provided, the hazard can be reduced by
installing a range hood that projects horizontally a
minimum of 5" beyond the bottom of the cabinets.
• Range complies with U.L. requirements for 2"
clearance from the range to adjacent vertical side walls
and 0" from rear wall. Abnormal surface unit operation
could result in possible scorching of vertical walls and
pose potential fire hazard. Therefore, a 6" minimum
spacing is recommended.
• For Free-standing installations the cutout opening
width is 30 1/8" ± 1/16" minimum. The height of the
countertop is 36" and countertop depth is 25". The
cooktop does NOT need to be notched for
Free-standing installations.
• See page 2 for Slide-in installation specifications
See page 2-5 for additional information
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
35 1/2"
20"
36"
35 1/2"
174
35 1/2"
Wall View
(not to scale)
4 1/2"
Wall View
(not to scale)
18"
36"
Countertop
height
20"
Locate electrical
supply junction
box or 60" of
electrical cable
within shaded
area. Locate gas
supply in the solid
area
1"
5"
5"
5"
Upper cabinets
can only be 13"
deep maximum.
Over range
30" Min.
30"
Range
BN226 • A174B121C150D123E124 • • 020611 • 72418 • 12627
cabinet is NOT
recommended.
Minimum horizontal
clearance between the
edge of the appliance
and combustible
construction extending
6"
from the cooking
surface to 18" above
the cooking surface is
2" to the sides and 0" to
the back (see solid
areas). 6" Minimum is
recommended.
30 1/8" Minimum cutout
width for Free-standing
instalations.
(not to scale)
3"
6"
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Gas requirements: Install a manual shutoff valve in an accessible
location in the gas line external to this appliance for the purpose of
turning on or shutting off gas to the appliance. The appliance is
shipped from the factory equipped for use with natural gas and can be
converted to LP gas in the field . The maximum gas supply pressure
for the regulator supplied on this appliance is 14" WC. The test
pressure for checking this regulator must be at least 6" WC for natural
gas, and at least 11" WC for LP. It is shipped from the factory set for
natural gas at 5" WC.
• For European style cabinets (flush front) the required clearance for
operation of the oven door is a minimum spacing of 7/8" between the
cutout and adjacent door, hinge or drawer of the cabinet.
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Downdraft Gas Professional Grill-Range Oven:
• Island or peninsula installations with 24" deep base cabinets must
use flush back (no rear toe space) cabinets to avoid range
interference,. If rear toe space is desired, use 27" or deeper
cabinets.
• Accepts Jenn-Air Designer Style cartridges.
• SVD8310S : Stainless Steel.
Kits:
• A501S : 2 Stainless steel side panels for freestanding range
installations.
• A508S : Custom backsplash (12") for freestanding range
installations.
• A510 : Trim Kit base for freestanding range installations.
• A518S : 30" high deluxe Stainless lighted backsplash.
29 3/8" countertop
opening
SVD8310S
If the countertop overhangs the cabinet 1/2"
to 1" the overall cutout depth is 22 7/8".
If the countertop overhangs the cabinet 1" to
1 3/4" the overall cutout depth is 23 3/16".
1/2" minimum flat
surface from back
edge of cutout
countertop thickness
1 3/4" Minimum from wall to
Cross Section
(not to scale)
rear countertop opening
21 1/8" from rear
Cabinet opening and from
notch edge to notch edge
1 5/8" Maximum
cutout to notch
(cabinet face)
29 7/8"
Slide-in installation
36" to Floor
(not to scale)
1/4"
29 7/8"
notch to notch
Notch on both
sides of opening
(not to scale)
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
BN226 • A174B121C150D123E124 • • 020611 • 72418 • 12627