Jenn-Air PRD3630 Installation Instruction

Professional 30”and 36” Dual Fuel Range Models
INSTALLATION
MANUAL
Retain this manual for future reference.
400 WEST FOURTH STREET,NORTH • NEWTON, IA 50208
17665 REV.C 04/2004
1
Maytag Services sm Attn: CAIRR Center P. O. Box 2370 Cleveland,TN 37320-2370
WAR NI NG
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
WAR NI NG
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY
IF YOU SMELL GAS:
Do not try to light any appliance.Do not touch any electrical switch; do not use any phone in your building.Immediately call your gas supplier from a neighbor’s phone.Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
WAR NING:
Gas leaks may occur in your system and result in a dangerous situation. Gas leaks may not be detected by smell alone. Gas suppliers recommend you purchase and install an UL approved gas detector. Install and use in accordance with the manufacturer’s instructions.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
A MESSAGE TO OUR CUSTOMERS
TABLE OF CONTENTS
2
INTRODUCTION..................................................................................................................................................................3
MODEL IDENTIFICATION.............................................................................................................................................4
UNPACKING AND HANDLING .............................................................................................................................5-6
VENTILATION REQUIREMENTS...............................................................................................................................7
INSTALLING ANTI-TIP DEVICE.................................................................................................................................8
CABINET PREPARATION.........................................................................................................................................9-11
BACKGUARD INSTALLATION.................................................................................................................................12
ELECTRICAL / GAS CONNECTIONS.............................................................................................................12-13
HOOK-UP TO GAS SUPPLY................................................................................................................................13-14
INSTALLER FINAL CHECKLIST...............................................................................................................................15
WIRING DIAGRAM/SCHEMATIC....................................................................................................................16-19
PRD3030 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
PRD3030 SCHEMATIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
PRD3630 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
PRD3630 SCHEMATIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
WAR RANT Y ...................................................................................................................................................................20-21
INTRODUCTION
3
Jenn-Air Professional Ranges are designed with a number of unique features certain to provide years of cooking enjoyment for the novice or experienced chef.Ranges are available in 30” and 36” widths. The large capacity electric ovens of the Dual Fuel Range are self-cleaning and feature convection baking. All models offer a minimum of (4) 15,000 Btu/hr sealed top burners. Dual-flow simmer burners are provided,and offer a low turn down of 570-1,200 Btu/hr.
IMPORTANT INSTALLATION INFORMATION
The Jenn-Air Professional Series is tested in accordance to UL Standard 858 and ANSI Z21.1. These ranges must be installed in conjunction with a suitable overhead vent hood. Due to the high heat capacity of this unit, particular attention should be paid to the hood and duct work installation to ensure it meets local building codes. To eliminate risk of burns or fire by reaching over heated surface units, cabinet storage located above the surface units should be avoided.
Check local building codes for the proper method of range installation. Local codes vary. Installation, electrical connections, and grounding must comply with all applicable codes. In the absence of local codes,the range should be installed in accordance with the National Fuel Gas Code ANSI Z223.1-1988 and National Electrical Code ANSI / NFPA 70-1990. Be sure that the unit being installed is set up for the kind of gas being used. The dual fuel range is shipped from the factory set and adjusted for Natural Gas. It can be field-converted for LP (propane) by a qualified technician using the orifices provided with the unit. Refer to instructions included with the conversion kit that is packed with the unit. Ver ify
that the range is compatible with gas supply at the installation site before proceeding further.
All ranges must be installed with one of three backguards (This piece must be ordered separately) except model PRD3030,which is shipped standard with a 9”low backguard. See figure below for sizes and model numbers.
22” High Shelf Backguard option Model PRAD3022 (30”) Model PRAD3622 (36”)
12” Lowback option Model PRAD3612 9” Lowback (30 models only)
Island Trim Model PRAD3001 (30”) Model PRAD3601 (36”)
Fig. 1
MODEL IDENTIFICATION
4
36” DUAL FUEL RANGE MODEL
MODEL PRD3630
30” DUAL FUEL RANGE MODEL
MODEL PRD3030
OVEN ON HEATING
HEATING
DOOR LOCKED
5
UNPACKING AND HANDLING
MOVING AND PLACING THE RANGE
The ranges have shipping weights varying from 420 lbs. to 630 lbs. less approx. 50 lbs. after removal of packing material. It is recommended that the door, grates, and front kick panel be removed to facilitate handling. This will reduce the weight for ease of handling.
CAUTION:
Proper equipment and adequate manpower must be used in moving the range to avoid damage to the unit or the floor. The unit is heavy and rests on adjustable steel legs.
WAR NING:
DO NOT lift range by the oven door handles!!
It may be necessary to remove the oven doors and knobs to pass through some doorways. With the doors and knobs removed,a 29-1/16”(PRD3630)/28-1/2” (PRD3030) wide opening is required. Without removing the door, a 31-1/2” (PRD3630) / 30”(PRD3030) wide opening is required. Remove the outer carton and packing material from the shipping base.
Fig. 2
Fig. 3
Left Rear Shipping Screws
Kick Panel
Left Rear Shipping Screws
6
UNPACKING AND HANDLING
Remove the kick panel by removing two screws at the top and pulling forward. The range is held to the skid by two bolts in the front behind the kick panel, (fig. 3) and two L-brackets located on the bottom flange of the range back (fig. 3). After removing the bolts and brackets, the range must be lifted and removed from the skid.
Due to the weight,a dolly with soft wheels should be used to move this unit. The weight must be supported, uniformly across the bottom (fig. 4). To remove the door, open the door and hold it all the way open. Close the hinge latches (fig.5) and release the door. The door can then be removed by gently lifting and pulling the door, with the hinges up and out of the frame (fig. 6).
The professional range should be transported by a dolly close to its final location. The range can be tipped back and supported on the rear legs while the dolly is removed. The floor under the legs should be protected (Wood Strips, Carpet, Paneling, etc.) before pushing the unit back into position.
Fig. 4
Range Must be Uniformly Supported on Braces
Leveling Legs
MOVING AND PLACING THE RANGE
Electric and gas connections should be made before the range is slid into the cabinet opening (see page 9 & 10). The backguard or island trim should also be installed before the range is placed in its final position (refer to page 12). For proper performance, the professional range should be level. To achieve a flush fit of the range to adjoining countertops, it will be necessary to have level cabinets (front to back, and left to right across opening of the range). After checking the countertops for level and before sliding the range into place,measure the distance from the floor to the top of the counter work surface in the rear left and right corners. Adjust the corresponding rear corner of the range to an equal height of the counter, as the rear leveling legs are not accessible once the range is pushed into place. Once the range is in place, the front leg levelers can be accessed to level the front of the range. Replace the kick panel and oven door by reversing the procedure described previously. It is important that the two screws retaining the kick panel are secure to prevent accidental access to live electrical components and wires (fig. 2).
Fig. 5
Lock (close)
Unlock
Fig. 6
Lock (close)
Unlock
DOOR HINGE ROLLER-
LEFT
DOOR HINGE ROLLER-
RIGHT
Leveling Legs
Range Must be Uniformly Supported on Braces
22"
DOOR HINGE ROLLER
DOOR HINGE ROLLER
7
VENTILATION REQUIREMENTS
A suitable exhaust hood must be installed above the range. The following chart indicates the minimum blower capacity recommended for hood ventilation.
CAUTION:
Ventilation hoods and blowers are designed for use with single wall ducting. However, some local building codes or inspectors may require double wall ducting. Consult local building codes and/or local agencies,before starting, to ensure that hood and duct installation will meet local requirements.
Hood blower speeds should be variable to reduce noise and loss of heated or air conditioned household air when maximum ventilation is not required. Normally, the maximum blower speed is only required when using the grill.
For best smoke elimination, the lower edge of the hood should be installed a minimum of 30" to a maximum of 36" above the range cooking surface, (page 10 & 11). If the hood contains any combustible materials (i.e. a wood covering) it must be a minimum of 36" above the cooking surface.
Due to a high volume of ventilation air, a source of outside replacement air is recommended. This is particularly important for tightly sealed and insulated homes. A reputable heating and ventilating contractor should be consulted.
VENTILATION STANDARD COUNTER ISLAND
UNIT INSTALLATION INSTALLATION
RECOMMENDATIONS RECOMMENDATIONS
HOOD (24" Deep x Unit Width) (30" Deep x 36" at Bottom)
BLOWER 36" RANGE
600-1200 CFM 600-1200 CFM
30" RANGE
600 CFM 600 CFM
8
INSTALLING ANTI-TIP DEVICE
All ranges must have an anti-tip device correctly installed as per the following instructions. If you pull the range out from the wall for any reason,make sure that the device is properly engaged when you push the range back against the wall. If it is not, there is a possible risk of the range tipping over and causing injury if you or a child stand,sit or lean on an open oven door.
INCLUDED PARTS: Included with this kit are:
(4) #10 x 2” wood screws, (1) Anti-tip bracket, and (1) Installation Instructions.
INSTALLING THE KIT:
Instructions are provided for wood and cement floors. Any other type of construction may require special instal­lation techniques as deemed necessary to provide adequate fastening of the Anti-tip bracket to the floor and wall. The use of this bracket does not preclude tipping of the range when not properly installed.
WOOD CONSTRUCTION:
Place the bracket against the back wall,into the right rear corner where the range is to be located. Leave a gap between the wall (or side of range) and the bracket (see fig.7). Drill (2) 1/8” diameter pilot holes in the center of the small holes. A nail or awl may be used if a drill is not available. Fasten the bracket securely to the floor and wall.
CONCRETE OR CEMENT CONSTRUCTION: Hardware Required:
(2) sleeve anchors, lag bolts, and washers (not provided). Locate the bracket as described above. Drill the recommended size holes for the hardware. Install the sleeve anchors into the holes and then install the lag bolts through the bracket. The bolts must be properly tightened as recommended for the hardware. Fasten the bracket securely to the floor and wall.
ONCE INSTALLED:
Complete the range installation per the instructions provided with the product. Check for proper installation of the range and Anti-tip device by grasping the back of the unit and carefully attempt to tilt the range forward.
A=
1/4”
Model
Series
PRD3030
5/8”
PRD3630
Fig. 8
Fig. 7
(2) Large Holes for
Concrete Installations
(2)Small Holes for
Wood Installations
(2) Wood Screws into
Back Wall (ALL
Installations)
BACK WAL L
RIGHT SIDE OF
WALL OR RANGE
A
WARNING
ALL RANGES CAN TIP
INJURY COULD RESULT
INSTALL ANTI-TIP BRACKET PACKED INSIDE OVEN
SEE INSTRUCTIONS
9
CABINET PREPARATION
1) The range is a free standing unit. If the unit is to be placed adjacent to cabinets,the clearances
shown in fig. 9 (PRD3630) & fig. 10 (PRD3030) are required. The same clearances apply to island installations.
2) The range can be placed in various positions with respect to the cabinet front,with the front either
flush or projecting, depending on the countertop depth.
3) The gas and electrical supply should be within the zones shown (fig. 9, 10 & 11).
4) The maximum depth of over head cabinets installed on either side of the hood is 13”.
5) Any openings in the wall behind the range and in the floor under the range must be sealed.
6) When there is less than a 12” clearance between combustible material and the back edge of the
range (above the cooking surface), a Low backguard or High Shelf backguard must be installed, (fig. 12-Island ). When clearance to combustible material is over 12”, an island trim may be installed (fig. 12-Standard). These parts must be ordered separately (model PRD3030 is shipped standard with a 9”Low backguard). Fig.12 indicates the space required for each type of backguard.
7) Always keep the appliance area clear and free from combustible materials,gasoline and other
flammable vapors and liquids.
8) Do not obstruct the flow of combustion and ventilation air to the unit.
Fig. 9 PRD3630 Model Only
min. 36" wide hood
13"
12" min. to combustible
18 " M i n .
35-3/8" max. for level counter, 36-3/4" max. with range
leveling legs fully extended
As defined in the “National Fuel Gas Code” (ANSI Z223.1, lastest edition).
material , each side
4 "
3-1/4 "
gas supply
12 "
cooking surface
electrical
3-1/2 "
supply
12 "
Max
4 "
CAUTION: 36" min. to combustible material , from cooking surface
The horizontal surfaces of the range top (cooktop) trim must not be below countertop level.
10
CABINET PREPARATION
Fig. 11 All PRD Models
Fig. 10 PRD3030 Model Only
min. 30" wide hood
12" min. to combustible
18 " M i n .
material , each side
9"
7"
cooking surface
4"
1-1/2"
gas supply
35-3/4" max. for level counter, 37" max. with range
leveling legs fully extended
As defined in the “National Fuel Gas Code” (ANSI Z223.1, lastest edition).
The horizontal surfaces of the range top (cooktop) trim must not be below countertop level.
10-3/4"
electrical supply
13"
Max
CAUTION: 36" min. to combustible material ,
2"
from cooking surface
2" Maximum Protrusion from Wall for Gas Supply
Gas Supply
Manual Shut-Off Valve must be Easily Accessible
Flex Line to Range
Electrical Supply
NEMA 14-50 Receptacle
11
CABINET PREPARATION
Fig. 12 All PRD Models Product / Installation Clearance Specifications
ABC D E F G H I J K
PRD3630 22” 12” 2” 35-1/2”min.–37” max. 30-1/4” 44-1/2” 28-1/4” 1-5/16” 25” 27-3/8” 35-7/8” PRD3030 22” 9” 2” 35-3/4” min.–37”max. 28-3/16” 43-7/8” 27-3/8” 1-5/16” 24-3/16” 26-3/4” 29-7/8”
STANDARD INSTALLATION:
ISLAND INSTALLATION:
K
K
PRD3630 Model PRD3030 Model
Low Backguard
(Dim. “B”)
High Shelf Backguard
(Dim.“A”)
Island Trim
G
A
B
D
H
0” Clearance
E
F
12 " M i n. to Combu stibles without backguard
36" Min. to Combu stibles
C
0” Clearance
I J
As defined in the “National Fuel Gas Code” (ANSI Z223.1, Latest Edition).
The horizontal surfaces of the range top (cooktop) trim must not be below countertop level.
12
BACKGUARD KITS:
Model PRD3030 is shipped standard with a 9”Low backguard. High Shelf backguards,Island Trims and the Low Back for Model PRD3630 must be ordered separately. Specific instructions for installation of the High Shelf backguard, Low backguard or Island Trim Backguard can be found packaged with the backguard. All backguards or island trims must be installed on the range before the unit is pushed into the cabinet. A backguard must be installed when there is less than a 12” clearance between combustibles and the back of the range (above the cooking surface). See fig. 12. Refer to page 3 for backguard model numbers.
ELECTRICAL CONNECTIONS PRD3630 model
Always disconnect electric supply cord from the wall outlet or service disconnect before servicing this appliance. Observe all governing codes and ordinances when grounding,in absence of which,observe National Electrical Code ANSI / NFPA No. 70-1990. The electrical supply must be a 120/240 volt, 3 wire (plus ground) 60 Hz single phase,50 AMP circuit. The power receptacle must be a NEMA 14-50 device to accept the four prong plug supplied with the unit.The receptacle should be located within the area shown in fig.9 page 9.
PRD3030 MODEL
The electrical supply must be a 120/240 volt, 3 wire (plus ground), 60 Hz, 30 AMP circuit. The power receptacle must be a NEMA 14-50 device to accept the four prong plug supplied with the unit. The receptacle should be located within the area shown in fig.10, page 10.
BACKGUARD INSTALLATION
ELECTRICAL / GAS CONNECTIONS
Fig. 13
NEMA 14-50
Receptacle
Electrical Supply
Valve must be Easily Accessible
Electrical Supply
m from Wall pply
NEMA 14-50 Receptacle
13
ELECTRICAL / GAS CONNECTIONS
RECOMMENDED GROUNDING METHOD
This appliance is factory equipped with a power supply cord with a four-prong grounding plug. It must be plugged into a mating grounding,type receptacle,connected to a correctly polarized 120/240 volt circuit. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the installer to have the existing receptacle changed to a properly grounded and polarized receptacle in accordance with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes and ordinances, the receptacle replacement shall be in accordance with the National Electrical Code.
THE FOURTH PRONG (ROUND GROUNDING PIN) SHOULD NOT, UNDER ANY CIRCUMSTANCES,BE CUT OR REMOVED.
GAS REQUIREMENTS
Verify the type of gas supplied to the location. The range is shipped from the factory set up and adjusted for natural gas. It can be field-converted for LP (propane) gas. Refer to instructions included with the conversion kit that is packed with the unit.
NATURAL GAS
Connection: 1/2” N.P.T. Minimum 5/8” dia.flex line.  Supply Pressure: 6” to 14”W.C.
LP GAS
Connection: 1/2” N.P.T. Minimum 5/8 dia. flex line. Supply Pressure: 11” to 14”W.C.
A regulator is required at the LP source to provide a maximum of 14”W.C. to the range regulator.
HOOK-UP
A manual valve must be installed external to the appliance,in an accessible location from the front for the purpose of shutting off the gas supply. The supply line must not protrude beyond the back of the unit. Make sure the gas supply is turned off at the wall valve before connecting the appliance.
The gas supply connections should be made by a qualified technician and in accordance with local codes or ordinances. In the absence of a local code, the installation must conform to the National Fuel Gas Code ANSI 223.1-1988, latest edition.
HOOK-UP TO GAS SUPPLY
14
CAUTION:
The appliance must be isolated from the building’s gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa.). The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at the test pressures in excess of 1/2 psig (3.5kPa.).” When checking the manifold gas pressure, the inlet pressure to the regulator should be at least 7.0” W.C. (Water Column) for natural gas or 12.0”for LP.
NOTE: The flex line for the gas supply must be metal and be approved by an approved
certifying agency (AGA, CGA,or UL). Never use a hose made of rubber or other synthetic material, as the heat may cause the hose to melt and develop leaks.
When hooking up the gas supply from range rear hard pipe to wall hard pipe, installation length of flex line between range/wall hard piping must accommodate range being pulled from wall for cleaning or servicing purposes. When range is pulled from wall,no strain should occur at range or wall hard pipe connections (fig. 14).
HOOK-UP TO GAS SUPPLY
Fig. 14
Manual Shut-Off Valve must be Easily Accessible
WALL Hard Pipe Connection
Hard Pipe 1/2" NPT
Metal Flex Gas Line
15
INSTALLER FINAL CHECKLIST
GENERAL
Placement of unit.
Specified clearance maintained to cabinet surfaces.
Unit Level - front to back, side to side.
All packaging material and tie straps removed, drip pans clean and empty.
Backguard attached if there is less than 12" clearance above the cooking surface to combustibl
construction behind unit.
Island trim attached if there is more than 12” clearance above the cooking surface to the
combustible construction behind the unit.
ELECTRICAL
Receptacle with 50 ampere over-current protection (30A for PRD3030) is provided for service
cord connection.
Adequate ground connection.
Front kick panel in place and two (2) screws secure.
GAS SUPPLY
Connection: 1/2 NPT with a minimum 5/8" diameter flex line. Site gas supply is compatible with
range model, & sufficient pressure is available (see gas requirements pg. 13).
The pressure regulator which is connected to the manifold is set for 5.0 W.C. for natural gas or
10.0 W.C.for LP.
Manual gas shut-off valve installed in an accessible location.
Unit tested and free of gas leaks.
OPERATION
All internal packing materials removed. Check below grate, pans and drip drawers.
If used on LP gas, verify that pressure regulator,orifices,and valve bypass jets have been set for
use with LP gas.
Bezels centered on burner knobs and knobs turn freely.
Each burner lights satisfactorily, both individually and with other burners.
Oven door hinges seated and door opens and closes properly.
Burner grates correctly positioned, level, and do not rock.
PRD3030 WIRING DIAGRAM
16
PRD3030 SCHEMATIC
17
PRD3630 WIRING DIAGRAM
18
PRD3630 SCHEMATIC
19
20
WARRANTY
FULL ONE YEAR WARRANTY - PARTS AND LABOR
For one (1) year from the original retail purchase date, any part which fails in normal home use will be repaired or replaced free of charge.
Limited Warranties - Parts Only
Second Year - After the first year from the original purchase date, parts which fail in normal home use will be repaired or replaced free of charge for the part itself, with the owner paying all other costs, including labor,mileage and transportation, trip charge and diagnostic charge, if required.
Third Through Fifth Year - From the original purchase date, parts listed below which fail in normal home use will be repaired or replaced free of charge for the part itself,with the owner paying all other costs, including labor, mileage and transportation, trip charge and diagnostic charge, if required.
Electronic Controls
Electric Heating Elements:Broil and bake elements on gas and electric cooking appliances.
Sealed Gas Burners
CANADIAN RESIDENTS
The above warranties only cover an appliance installed in Canada that has been certified or listed by appropriate test agencies for compliance to a National Standard of Canada unless the appliance was brought into Canada due to transfer of residence from the United States to Canada.
Limited Warranty Outside the United States and Canada - Parts Only
For two (2) years from the date of original retail purchase,any part which fails in normal home use will be repaired or replaced free of charge for the part itself, with the owner paying all other costs, including labor,mileage and transportation, trip charge and diagnostic charge, if required.
The specific warranties expressed above are the ONLY warranties provided by the manufacturer. These warranties give you specific legal rights, and you may also have other rights which vary from state to state.
WHAT IS NOT COVERED BY THESE WARRANTIES:
1. Conditions and damages resulting from any of the following:
a. Improper installation, delivery, or maintenance.
b. Any repair, modification,alteration, or adjustment not authorized by the manufacturer or an
authorized servicer.
c. Misuse, abuse, accidents,or unreasonable use.
d. Incorrect electric current, voltage, or supply.
e. Improper setting of any control.
2Warranties are void if the original serial numbers have been removed, altered, or cannot be
readily determined.
3. Light bulbs.
4. Products purchased for commercial or industrial use.
5. The cost of service or service call to:
a. Correct installation errors.
b. Instruct the user on the proper use of the product.
c. Transport the appliance to the servicer.
21
WARRANTY
6. Consequential or incidental damages sustained by any person as a result of any breach of these warranties. Some states do not allow the exclusion or limitation of consequential or incidental damages, so the above exclusion may not apply.
IF YOU NEED SERVICE
Call the dealer from whom your appliance was purchased or call Maytag ServicesSM,Jenn-Air Customer Assistance at 1-800-JENNAIR (1-800-536-6247) to locate an authorized servicer.
Be sure to retain proof of purchase to verify warranty status. Refer to WARRANTY for further information on owner’s responsibilities for warranty service.
If the dealer or service company cannot resolve the problem, write to Maytag ServicesSM,Attn: CAIR® Center, P.O. Box 2370,Cleveland,TN 37320-2370, or call 1-800-JENNAIR (1-800-536-6247) .
U.S. customers using TTY for deaf, hearing impaired or speech impaired,call 1-800-688-2080.
NOTE:When writing or calling about a service problem, please include the following information:
a. Your name, address and telephone number;
b. Model number and serial number;
c. Name and address of your dealer or servicer;
d. A clear description of the problem you are having;
e. Proof of purchase (sales receipt).
User’s guides, service manuals and parts information are available from Maytag ServicesSM, Jenn-Air Customer Assistance.
1-800-JENNAIR (1-800-536-6247) 1-800-688-2080 (U.S.TTY for hearing or speech impaired)
Mon. - Fri., 8 am - 8 pm Eastern Time Internet: www.jennair.com
Maytag Services
sm
Attn: CAIR® Center,P.O. Box 2370, Cleveland,TN 37320-2370
NOTES
22
Loading...
+ 52 hidden pages