PRODUCT MODEL SERIES PRODUCT DIMENSIONS
JMV8208D
Electrical: A 120-Volt, 60-Hz, AC-only, 15- or 20-amp fused electrical supply
with a fuse or circuit breaker. A time-delay fuse or time-delay circuit
breaker is recommended. It is recommended that a separate circuit serving
only this microwave oven be provided.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10188238A
12/09
Microwave Hood Combination
VENTING REQUIREMENTS
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should
be used.
The total length of the vent system including straight vent, elbow(s),
transitions and wall or roof caps must not exceed the equivalent of 140 ft
(42.7 m) for either type of vent.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the equivalent length for
each vent piece used in the system. See the following examples:
CABINET OPENING DIMENSIONS
6" (15.2 cm) vent system = 73 ft (22.2 m) total
A B
CD
6 ft (1.8 m)
2 ft
(0.6 m)
A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 1 rectangular to round transition
piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m)
straight = 8 ft (2.4 m)
A. Rectangular to round transition piece: 3
" x 10" to 6" = 5 ft
(8.3 x 25.4 cm to 15.2 cm = 1.5 m)
B. Roof cap: 3
" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)
C. 90° elbow: 3
" x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)
D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)
E. Wall cap: 3
" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)
F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m)
G. 90° flat elbow: 3
" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)
A B C
D E F G
3 " x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total
A. One 3 " x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
A B
C
6 ft (1.8 m)
2 ft
(0.6 m)
Rectangular to Round Transition for Roof Venting
NOTE: The minimum 3" (7.6 cm) clearance must exist between
the top of the microwave oven and the rectangular to round
transition piece so that the damper can open freely and fully.
A
B
C
3" (7.6 cm)
A. Roof cap
B. 6" (15.2 cm) min. diameter round vent
C. Elbow (for wall venting only)
D. Wall cap
E. 3
" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm)
rectangular to round transition piece
F. Vent extension piece, at least 3" (7.6 cm) high
"
¹⁵⁄₁₆
16
(43.0 cm)
51
⁄¹
₂
"
3(
4.9
mc
)
The grounded 3 prong outlet must be inside the upper
.6
7
(
"
₈
⁄⁷
9
2
A
"
⁷⁄₈
15
(40.4 cm)
)
m
c
0
cabinet.
B
30"
(76.2 cm)
min.
30" (76.2 cm) typical*
66" (167.6 cm) min.
12" (30.5 cm) min.
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary dependin
on type of range/cooktop