Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
IMPORTANT :
À conserver pour consultation par l’inspecteur local des installations électriques.
Installateur : Remettre les instructions d’installation au propriétaire.
Propriétaire : Conserver les instructions d’installation pour référence ultérieure.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
follow instructions.
You
can be killed or seriously injured if you don't
instructions.
follow
– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
•
Do not touch any electrical switch.
•
Do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
•
instructions.
If you cannot reach your gas supplier, call the fire department.
•
– Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.
IMPORTANT: Do not install a ventilation system that blows air downward toward this gas cooking appliance. This type of
ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or
unintended operation.
2
In the State of Massachusetts, the following installation instructions apply:
■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
■ If using a ball valve, it shall be a T-handle type.
■ A flexible gas connector, when used, must not exceed 3 feet.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation instructions.
Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.
Re-engage the anti-tip bracket if the range is moved.
Do not operate range without anti-tip bracket installed and engaged.
Failure to follow these instructions can result in death or serious burns to children and adults.
To verify the anti-tip bracket is installed and engaged:
Anti-Tip
Bracket
Range Foot
• Slide range forward.
• Look for the anti-tip bracket securely attached to floor or wall.
Slide range back so rear range foot is under anti-tip bracket.•
• See installation instructions for details.
3
INSTALLATION REQUIREMENTS
Tools & Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools Needed
Pipe wrench
Drill
Level
C\zn" carbide tip masonry bit
Tape measure
Adjustable wrench
or 5⁄8" wrench
C\," drive ratchet
Tubing cutter
Z\," drill bit
Z\," x 41/4" flat-blade
screwdriver
ZB\zn" combination wrench
Z\v", C\,", B\zn" nut drivers
Pipe-joint compound
resistant to LP gas
#2 Phillips screwdriver
Pliers
Marker or pencil
Noncorrosive
leak-detection solution
4
B
Parts Supplied
Check that all parts are included:
Anti-tip bracket kit
A
A. Anti-tip bracket
B. #8-18 x 1" Phillips head screws (4)
NOTE: Anti-tip bracket must be securely mounted to
subfloor. Thickness of flooring may require longer screws
to anchor bracket to subfloor. Longer screws are available
from your local hardware store. See “Install Anti-Tip
Bracket” section.
Gas pressure regulator Burner grates Burner bases and burner caps Griddle drip tray (on griddle models)
Conversion Kits:
For models that start with JGRP or JLRP no conversion kits are
supplied. Call service to request one of the following:
NOTE: JLRP is factory set for LP. All other models are factory
set for Natural gas.
Parts Needed
All models must be installed with a backguard if installing
at zero clearance to a combustible back wall surface such
as drywall. Alternatively, zero clearance to a back wall is
acceptable provided the surface of the entire back wall
above the range and below the hood is covered with a
non-combustible material such as tile or stainless steel.
See “Cabinet Dimensions” in the “Location Requirements”
section for installation requirements.
30" (76.2 cm) Adjustable Backguard
Order Part Number 8285148
36" (91.4 cm) Adjustable Backguard
Order Part Number 8284756
48" (121.9 cm) Adjustable Backguard
Order Part Number 8284755
22" (55.9 cm) Backsplash with Dual-Position Shelf
for 30" (76.2 cm) Ranges
Order Part Number W10285447
22" (55.9 cm) Backsplash with Dual-Position Shelf
for 36" (91.4 cm) Ranges
Order Part Number W10285448
22" (55.9 cm) Backsplash with Dual-Position Shelf
for 48" (121.9 cm) Ranges
Order Part Number W10285449
To order, see the “Assistance or Service” section of the
Use and Care Guide.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See the “Electrical Requirements”
and “Gas Supply Requirements” sections.
It is recommended that all electrical connections be made by
a licensed, qualified electrical installer.
High Altitude Conversion
To convert the cooktop for elevations above 6,560 ft (1999.5 m),
order a High Altitude Conversion Kit.
Part Number W10394294 – LP high altitude
Part Number W10394293 – Natural gas high altitude
To order, see the “Assistance or Service” section of the Use
and Care Guide.