Built-In 27" & 30"
+I'M _"]l+[+"]!4_+vl_!l[,_VJ=l+l
11/4" Dia.ConduitAccessHole*
2 5/8" PlywoodFloor(MustSupport200ibs.)
DIMENSIONS
inches cm
A 27 MIN 68.58
B 24 MIN 60.96
C 29 1/16+_1/16 73.82
D 24 MIN 60.96
E 25 1/2+ 1/16 64.77
F 29 1/2 74.93
G 26 3/4 67.95
H 25 7/16 64.61
I 4to31 10.2to 78.7
P;r+ II[,]lJ :1! :liV_vl:1! I[o_'J:1+I
11/4" Dia.ConduitAccessHole*
2 5/8" PlywoodFloor(MustSupport310Ibs.)
DIMENSIONS
inches cm
A 27 MIN 68.58
B 24 MIN 60.96
C 51 7/8+1/16 131.76
D 24 MIN 60.96
E 25 1/2+ 1/16 64.77
F 52 1/4 132.72
G 26 3/4 67.95
H 25 1/2 64.77
I 4to 10 10.2to 25.4
Electric Wall Ovens =JENN-AIR 1
1 1/4" Dia.ConduitAccessHole*
2
5/8" PlywoodFloor(MustSupport200Ibs.)
DIMENSIONS
inches
A
B
C
D
E
F
G
H
I
2 5/8" PlywoodFloor(MustSupport310Ibs.)
A 30MIN 76.20
B 24MIN 60.96
C 51 7/8+_1/16 131.76
D 24 MIN 60.96
E 281/2+_1/16 72.39
F 52 1/4 132.72
G 293/4 75.57
H 25 1/2 64.77
I 4to10 10.2to 25.4
30 MIN
24 MIN
291/16+1/16
24 MIN
281/2+1/16
291/2
293/4
257/16 Art #: 9220-025
4to 31
kI,]iIJl,llJ :]! 4W;I ! I[,]'1::I+I
1 1/4" Dia. ConduitAccessHole*
DIMENSIONS
inches cm
403 WEST FOURTH STREET, NORTH
NEWTON, IA 50208
DOUBLEWALL OVEN
I_[e]id_l
Donotblockairexhaustslotsalongbottom
ofoven.
Y Gasorelectriccooktopsmaybe installed
overovens. Seecooktopinstallation
instructionsforcutoutsize.**
W Electricalconnectionforelectriccooktop
mustinadjacentaccessiblelocation.Cook
topand wallovenmustbe onseparate
120/240or120/208volt60HzACcircuits.
CAUTION
For European style cabinets (flush
front) the required clearance for
operation of the oven door is
minimum spacing of 7/8" between
the cutout and the door. hinge or
drawer of the cabinet.
Some built-in cabinets may not be
wide enough, due to their construc-
tion to allow this installation.
NOTE:
* Holemustbecutas closetocornerofcabinetas possible.
** Seedealerforapprovedcooktops.
i'_I+1rI_,IIl[l_.+'l::I+II J+Ii]::I:ll..ll].lJ+II ::I:
1 1 1/4" Dia.ConduitAccessHole*
2 5/8" PlywoodFloor(MustSupport200Ibs.)
DIMENSIONS
inches cm
A 25 63.50
B 24 MIN 60.96
C 291/16+_1/16 73.82
D 24 MIN 60.96
E 281/2 72.39
F 29 1/2 74.93
G 293/4 75.57
H 25 7/16 64.61
I 36 91.44
J 1 1/2 3.81
cm
AiI JA Cooktops 7.62 MAX
'.-Z
UNDER COUNTERWALL OVEN
See pages 5, 6 and 7 for detailed installation
instructions.
J
Art #: 9220-027
8101 P602-60
(11-03-00)
Built-In 27" & 30" Electric
Combination Wall Ovens
1-1/4" Dia. Conduit Access Hole*
5/8" Plywood Floor (Must Support 275 Ibs.)
JENN-AIR
403 WEST FOURTH STREET, NORTH
NEWTON, IA 50208
[€[011L'ArI_,I! ! [o_vj_ _I H_.._] ;|I'JIi[o]_Ik.f-_i|W.'II llo]vl __IIH=[,.'[t]=tI',,111[o]_I
1-1/4" Dia. Conduit Access Hole*
5/8" Plywood Floor (Must Support 275 Ibs.)
DIMENSIONS
in cm
A 27 MIN 68.58 MIN
B 24 MIN 60.96 MIN
C 51-7/8 + 1/16 131.76+.16
D 24 MIN 60.96 MIN
E 25-1/2 + 1/16 64.77 + .16
F 52-15/16 134.46
G 26-3/4 67.95
H 25-7/16 64.61
I 4 to 10 10.2 to 25.4
* Hole must be cut as close to corner of cabinet as possible.
Do not block air exhaust slots along bottom of
oven.
COMBINATION WALLOVEN CUTOUT
DIMENSIONS
in cm
A 30 MIN 76.20 MIN
B 24 MIN 60.96 MIN
C 51-7/8 + 1/16 131.76+.16
D 24 MIN 60.96 MIN
E 28-1/2 + 1/16 72.39 + .16
F 52-15/16 134.46
G 29-3/4 75.57
H 25-7/16 64.61
I 4 to 10 10.2 to 25.4
CAUTION
For European style cabinets (flush front) the
reauired clearance for operation of the oven door
is minimum spacing of 7/8" between the cutout
and the door. hinge or drawer of the cabinet.
Some built-in cabinets may not be wide enough,
due to their construction, to allow this installation.
NOTE:
INSTALLED WALL OVEN OVERLAPS
CUTOUT 15/16" (2.38 CM) AT THE
TOP AND 1/8" (0.32 CM) AT THE
BOTTOM.
THIS MUST BE TAKEN INTO
CONSIDERATION WHEN LOCATING
CUTOUT IF INSTALLED UNIT IS TO
BE CENTERED IN THE CABINET.
[
f
Art #: 9220-028
Consult a qualified electrician or serviceman if the
grounding instructions are not completely understood, if
doubt exists as whether the appliance is properly
grounded.
Installing Bottom Trim Piece
Remove lower screws from hinge
receptacle plates. Align lower trim
and reinstall screws.
CAUTION
For European style cabinets (flush front) the required
clearance for operation of the oven door is min mum
spacing of 7/8" between the cutout and the door, hinge
or drawer of the cabinet.
Some bui t-in cabinets may not be wide enough, due to
their construction, to allow this installation.
Installation
1. Cut hole in cabinet to mount oven. Cutout in cabinet
should be level and straight.
NOTE: There are no provisions to level the unit after it
is installed. An oven that is not level could cause poor
baking results.
2. Install plywood floor as shown.
3. Remove oven door(s). See Oven Door Removal
procedure.
4. Attach unit to the cabinet with four No. 8 x 1" screws
supplied with unit inside of envelope containing these
instructions. Pre-drill holes in cabinet for attachment
screws using 1/8" drill. Oven mounting holes are
provided in side trim.
5. Install bottom trim.
6. Replace oven door(s). See Oven Door Replacement
procedure.
7. See instructions at right for electrical hook-up.
8. See Use and Care Manual for operating instructions.
DO NOT INSTALL BOTTOM TRIM UNTIL UNIT IS
ATTACHED TO THE CABINET.
Electrical Connections
Unit to be properly circuit protected and wired according
to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be
accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on
front of unit for power requirements.
The neutral of this unit is grounded to the frame through
the solid grounding wire. (The ground and the white wires
are twisted together at the termination of the conduit.) If
used on new branch-circuit installations (1996 NEC),
mobile homes, recreational vehicles, or in an area where
local codes prohibit grounding through the neutral
conductor, untwist or disconnect the ground wire and
connect to ground in accordance with local code. Connect
the white neutral to the service neutral. Connect all wires
to the branch circuit with approved connectors. Use
copper or aluminum wire. If aluminum wire is used, use
connectors recognized for joining aluminum to copper.
The chart below recommends the minimum circuit
protection and wire size if the appliance is the only unit on
the circuit.
RECOMMENDED MINIMUM
K.W. RATING CIRCUIT PROTECTION WIRE SIZE
ON SERIAL PLATE IN AMPERS (AWG)
0 - 4.8 20 12
4.9 - 6.9 30 10
7,0- 9.9 40 8
10.0 - 11.9 50 8
12.0 - 14.9 60 6
Service
Interrupt the source of electricity to the unit when
attempting to repair or service the oven. Failure to do this
could result in a dangerous or even fatal shock.
IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE