Jenn-Air JJW8527CAB, JJW8527CAS, JJW8527CAW Installation Guide

Built-In 27" & 30"
Electric Wall Ovens
403 WEST FOURTH STREET, NORTH
NEWTON, IA 50208
1 1/4" Dia. Conduit Access Hole*
2 5/8" Plywood Floor (Must Support 142 Ibs,)
DIMENSIONS
inches cm
A 27 MIN 68,58
B 24 MIN 60,96 C 27 7/16 + 1/16 69,69
D 23 1/2 MIN 59,69 E 25 1/2 +_1/16 64.77 F 27 3/4 70,49 G 26 3/4 67,95
H 24 7/16 62.07 I 4 to 33 10,2 to 83,8
1 1/4" Dia. Conduit Access Hole*
2 5/8" Plywood Floor (Must Support 250 Ibs,)
DIMENSIONS
inches cm
A 27 MIN 68,58
B 24 MIN 60,96 C 49 5/8 + 1/16 126,05 D 23 1/2 MIN 59,69
E 25 1/2 + 1/16 64.77 F 49 15/16 126,84 G 26 3/4 67,95 H 24 7/16 62.07
I 4to 12 10,2 to 30,5
l_Io] _.'_I_let!::KvAvhJ!I[olvJ__l
1 1/4" Dia. Conduit Access Hole*
2 5/8" Plywood Floor (Must Support 142 Ibs,)
DIMENSIONS
inches cm
A 30 MIN 76,20 B 24 MIN 60,96
C 27 7/16 + 1/16 69,69 D 23 1/2 MIN 59,69 E 28 3/16 +_1/16 71,60 F 27 3/4 70,49 G 29 3/4 75,57
H 24 7/16 62.07 I 4 to 33 10,2 to 83,8
l_Io] ItIoll1:1!:lVAVl-!!![olvJ=_1
1 1/4" Dia. Conduit Access Hole*
2 5/8" Plywood Floor (Must Support 250 Ibs,)
DIMENSIONS
inches cm
A 30 MIN 76,20 B 24 MIN 60,96
C 49 5/8 + 1/16 126,05 D 23 1/2 MIN 59,69
E 28 3/16 + 1/16 71,60 F 49 15/16 126,84 G 29 3/4 75,57 H 24 7/16 62.07
I 4to 12 10,2 to 30,5
SINGLEWALL OVEN
,1
Z
DOUBLEWALL OVEN
x_|VAVl:!!![olvJ=OlLIJ_lt]=;l[o[ollJ_ti=;!
1 1/4" Dia. Conduit Access Hole*
2
I 5/8" Plywood Floor (Must Support 142 Ibs.)
DIMENSIONS
inches cm
A 25 63,50
B 24 MIN 60,96 C 27 7/16 + 1/16 69,69
D 23 1/2 MIN 59,69 E 25 1/2 +_1/16 64,77 F 27 3/4 70,49 G 26 3/4 67,95
H 24 7/16 62.07 I 36 91,44
J 11/2 3,81
* * COOKTOPS inches cm inches
K 4 Burner Gas Glass Top 2 1/8 MIN 5,4 MIN 2 1/8 MIN 5,4 MIN K Electric 3 1/8 MIN 7.9 MIN 3 1/8 MIN 7.9 MIN
K Induction 3 1/8 MIN 7.9 MIN 3 1/8 MIN 7.9 MIN K 4 Burner Gas Stamped Top 4 13/16 MIN 12.2 MIN 4 13/16 MIN 12.2 MIN
1 1/4" Dia. Conduit Access Hole*
2
I 5/8" Plywood Floor (Must Support 142 Ibs,)
DIMENSIONS
inches cm
A 25 63,50 B 24 MIN 60,96
C 27 7/16 + 1/16 69,69 D 23 1/2 MIN 59,69 E 28 3/16 71,60 F 27 3/4 70,49 G 29 3/4 75,57 H 24 7/16 62.07 I 36 91,44
J 1 1/2 3,81
NOTE: * Hole must be cut as close to corner of cabinet as possible.
** See dealer for approved cooktops.
J E z
I_[o_i$1
Donotblockairintakeslots alongbottomofoven.
Y Gas or electriccooktopsmay beinstalledoverovens,
See cooktopinstallationinstructionsforcutoutsize,
W Electricalconnectionfor electriccooktopmustin adjacent
accessiblelocation.Cooktopandwalloven mustbeon separate
120/240or120/208volt60 Hz ACcircuits,
8101 P475-60
(03-02-00)
Wheninstallinga27"wallovenundera30"cooktop someinterferencemayoccur.Thefollowingcutout
notchingofthesidetrimswilleliminatetheinterferenceof thesidetrimtotheburnerbox.Aftercutting,filetheside
trimedgestoeliminateburrs.
Installing Bottom Trim Piece
Electrical Connections
Unit to be properly circuit protected and wired according to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on
front of unit for power requirements.
CAUTION
For European style cabinets (flush front) the required
clearance for operation of the oven door is minimum spacing of 7/8" between the cutout and the door, hinge
or drawer of the cabinet.
Some built-in cabinets may not be wide enough, due to
their construction, to allow this installation.
1. Cut hole in cabinet to mount oven. Cutout in cabinet should be level and straight.
NOTE: There are no provisions to level the unit after it is installed. An oven that is not level could cause poor
baking results.
2. Install plywood floor as shown.
3. Attach unit to the cabinet with four No. 8 x 1" screws supplied with unit inside of envelope containing these
instructions. Pre-drill holes in cabinet for attachment screws using 1/8" drill. Oven mounting holes are
provided in side trim.
4. See instructions at right for electrical hook-up.
5. See Use and Care Manual for operating instructions.
The neutral of this unit is grounded to the frame through the green or solid grounding wire. (The green and the
white wires are twisted together at the termination of the conduit.) If used on new branch-circuit installations (1996
NEC), mobile homes, recreational vehicles, or in an area where local codes prohibit grounding through the neutral
conductor, untwist or disconnect the green wire and connect the green wire to ground in accordance with local
code. Connect the white neutral to the service neutral. Connect all wires to the branch circuit with approved
connectors. Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.
The chart below recommends the minimum circuit protection and wire size if the appliance is the only unit on
the circuit.
RECOMMENDEDMINIMUM
K.W.RATING CIRCUITPROTECTION WIRESIZE
ONSERIALPLATE INAMPERS (AWG)
0- 4.8 20 12
4.9- 6.9 30 10
7.0- 9.9 40 8
10.0 - 11.9 50 8
12.0 - 14.9 60 6
Service
Interrupt the source of electricity to the unit when attempting to repair or service the oven. Failure to do this
could result in a dangerous or even fatal shock.
IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE