BACK VIEW
MODEL # JGCP436WP
in cm
A
Overall width 35
3
⁄4 90.7
B
Depth of grates 21
3
⁄4 55.2
C
Depth without control panel 23
1
⁄4 59.0
D
Depth with control panel
overhang
27
1
⁄8 68.9
E
Depth with knobs 28
3
⁄8 72.0
F
Width of grates 33 83.8
G
Center of rangetop to
center of gas inlet
14
1
⁄8 35.9
H
Height from gas inlet
to cooking surface
14
5
⁄8 37.1
I
Width of recessed rangetop 35 89.0
J
Height including grates 8
1
⁄2 21.7
K
Height of control panel 7
1
⁄2 19.0
L
Height to bullnose
5
3
⁄8 13.5
M
Height of recessed rangetop 7 17.7
N
Height to cooking surface 7
3
⁄8 18.8
O
Height of recessed rangetop
with grates
8
1
⁄2 21.6
P
Depth of recessed rangetop 22
1
⁄8 56.3
Q
Depth with control panel 26
1
⁄2 67.3
36" PRO-STYLE® RANGETOP
JGCP436WP – 353⁄4" x 145⁄8" x 283⁄8"
OPENING/CLEARANCE DIMENSIONS
MODEL # JGCP436WP
in cm
A
Width of combustible area above
cooking surface (min.)
36 91.4
B
Width from rangetop to fixed wall
or other combustible material (min.)
6 15.2
C
Width to inner edge of outlet (max.) 16 40.6
D*
Height to bottom of uncovered wood or
metal cabinet above cooking surface (min.)
42 106.7
E
Height to bottom of uncovered wood
or metal cabinet (min.)
18 45.7
F
Height to top edge of outlet (min.) 10 25.4
G
Height to gas supply line area 14 35.6
H
Depth of upper cabinet (recommended) 13 33.0
I**
Depth from cutout to wall 1
3
⁄4 4.4
J
Depth of cabinet 24 61.0
K
Height from cabinet to countertop 7
1
⁄4 18.4
L
Width of cutout (countertop and cabinet) 35
1
⁄4 89.5
M
Width of gas opening 12
1
⁄2 31.7
N
Width from cutout to gas opening 2 5.1
O
Width of notch
3
⁄8 1.0
Zero clearance
5
⁄16 0.8
P
Width of cutout (countertop only) 36 91.4
Zero clearance 35
7
⁄8 91.1
Q
Depth of gas opening 6
7
⁄8 17.5
R
Depth from cutout to gas opening
3
⁄4 1.9
S
Depth of cutout (countertop and cabinet) 22
1
⁄4 56.5
e
Recommended electrical outlet location
g
Recommended gas supply line location
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal
cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
If installing a hood above the rangetop, follow the hood instructions for
dimensional clearances above the cooking surface.
** If back wall is constructed of a combustible material and a backsplash is not
installed, a 43⁄4" (12.1 cm) minimum clearance is required.
GAS REQUIREMENTS
Natural Gas
This rangetop is factory-set for use with natural gas.
LP Gas Conversion
Conversion must be done by a qualified service technician. To convert
to LP gas, use the LP gas conversion kit provided with the rangetop.
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
A time-delay fuse or dedicated circuit is recommended.
FRONT VIEW