edges and prevent corner cracking (1/4" Radius).
www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
30" Electric Radiant Cooktops:
JEC9530ADB, JEC9530ADF and JEC9530ADS
• Dimensions (Actual Size) •
Overall width:
Overall depth:
Distance from countertop to bottom of unit:
Cut-Out width:
Cut-Out depth:
29 15/16"
21 1/2"
3 5/8"
29 1/16"
20 3/8"
Minimum spacing to nearest vertical
combustible wall to the RIGHT:
2 1/2"
Minimum spacing to nearest vertical
combustible wall to the LEFT:
2 1/2"
Minimum spacing to nearest vertical
combustible wall to the REAR:
Minimum spacing to front edge of counter:
3/4"
2 1/8"
Minimum distance between cooktop
and cabinet directly above:
Minimum width of cabinet directly above:
30"
30"
Maximum depth of cabinets directly
above and adjacent:
n/a
Minimum distance between countertop
and adjacent cabinet above:
n/a
• Additional Information •
• Electrical requirements : three-wire, single phase, AC
120/240volt, 60Hz. Properly grounded. Protected by
40 amp circuit. 48" flexible cable with 6" wire leads is
furnished. Locate electrical box a min. of 7" below the
cooktop
• Minimum clearance from top of counter to combustible
material below is 4 1/8".
• Countertop must be supported within 3" of cutout.
• Cabinetry over cooktop : 30' minimum clearance
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet. 24" minimum
when bottom of wood or metal cabinet is protected by
not less than 1/4" flame retardant millboard covered
with not less than no. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or copper.
• To eliminate the hazard of reaching over heated
surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage
is to be provided, the hazard can be reduced by
installing a range hood that projects horizontally a
minimum of 5" beyond the bottom of the cabinets.
• Radius corners of cutout and file to insure smooth
Side View (not to scale)
3/4"
2 1/8"
3 5/8"
Top View (not to scale)
20 3/8"
29 1/16"
2 1/2" 2 1/2"
30"
30"
n/a
29 15/16"
21 1/2"
Overall Dimensions
Cut-Out Dimensions
Countertop View
(not to scale)
Cabinet Requirements
Wall View
(not to scale)
Requires 2 1/2" wide
clearance to any
combustible surface
above the cooktop to
the right side and 2 1/2"
wide clearance to any
combustible surface
above the cooktop to
the left side. (noted by
solid area)
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
252
BN • A252 • • 032603 • 9570 • 42076