Dimensions (Actual Size)

 

 

Height at full leg adjustment:

35 1/4" Maximum

 

 

 

Height at 0" leg adjustment:

33 3/4" Minimum

 

 

 

Width:

23 7/8"

 

 

 

Depth:

23 1/2"

 

 

Door thickness incl. control panel:

3 1/2"

 

 

 

Door thickness:

1 1/2"

 

 

 

Depth with door open:

48 1/2"

 

 

 

Vertical toe space: 3" to 4 1/4"

 

 

 

Custom panel flange depth: 1/4"

 

 

 

Custom panel flange width: 5/16"

 

 

Additional Information

DRAIN:

32" Drain loop, 1/2" minimum I.D. Floor drains require a siphon break.

Drain hose extension kit available 904024.

When draining into a disposer, make sure disposer drain plug is removed.

WATER SUPPLY:

15 to 120 psi water pressure. 120°F to 140° hot water supply recommended.

Access for manual shut-off valve recommended.

3/8" compression to 3/8" male NPT fitting for water valve.

Suggested water line size 3/8" O.D. copper or equivalent.

ELECTRICAL SUPPLY:

120 volts, 60 Hz protected by a GROUNDED 15 amp fuse or comparable circuit breaker.

Max amperage draw 12.0 amps.

Minimum wire size 14 gauge (No. 12 wire preferred) - Copper only. Check all local codes.

Individual branch circuit serving only dishwasher recommended.

Electrical and water supplies should enter cabinet opening on the floor, or through the side walls as shown in shaded areas of drawing

IMPORTANT: ALWAYS CHECK LOCAL AND NATIONAL

CODES FOR FULL COMPLIANCE

See page 2 for additional information

Subject to change without notice. This system is designed to

 

be updated daily if necessary. Dimension Express is not

 

responsible for use of superseded, voided, or outdated data

 

sheets. Because of the difficulty or impracticability of deter-

 

mining actual damages, liability of Dimension Express shall

 

not exceed $50.00.

 

Copyright © Dimension Express, 2002.

307

23 1/2"

3 1/2"

Side View

(not to scale)

 

 

 

 

35 1/4" Maximum

 

1 1/2"

33 3/4" Minimum

 

 

 

48 1/2"

 

 

23 7/8"

 

Front View (not to scale)

 

 

 

 

 

 

1/4" Panel Size:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4" Panel Size:

 

 

35 1/4" Maximum

 

 

23 9/16" wide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

23 11/16" wide

 

 

33 3/4" Minimum

 

 

 

 

 

 

 

 

 

18 3/16" high

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 5/8" high

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3" to 4 1/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rough-in Information

Plumbing and

 

 

(Not to Scale)

electrical service

 

 

 

 

 

 

 

 

 

 

must enter inside

 

 

 

 

 

shaded area

 

 

 

 

 

Wall area

 

 

 

 

 

 

must be free

 

 

 

 

 

 

 

 

 

 

of pipes and

 

 

 

 

 

 

 

 

 

 

 

 

 

wires

24" Minimum

 

34" - 35"

8"

underside of

5"

countertop

3"

to floor

 

 

24" Minimum

7" from floor

5" from

back wall

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN130.61 • A307B149 • • 032603 • 95655 • 19743

associated with reusing old Data Sheets.

www.dexpress.com

 

 

 

 

This Data Sheet Includes Information On

 

 

 

 

DIMENSION EXPRESS

 

 

 

 

Jenn-Air

 

 

 

 

Page 2

 

 

Product Model Number (s):

 

 

 

 

 

 

 

 

Fax on Demand (775) 833-3600

 

 

 

24" Dishwashers:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JDB8910AWS, JDB8910AWW, JDB8910AWQ and

 

 

 

 

 

 

 

 

 

JDB8910AWB

 

 

 

 

Additional Information:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIPS:

Keep back free of drain, water and electrical supply.

Connections preferably located toward left side of dishwasher. Care should be taken to route pluming and electrical away from motor and blower.

When installing the dishwasher in or near a corner, allow enough room for the door to open without interfacing with any cabinet drawers of hardware.

Dishwasher side panel kits are available: 904025 White, 904025L Almond and 904025P Primer.

IMPORTANT: ALWAYS CHECK LOCAL AND NATIONAL CODES FOR FULL

COMPLIANCE

Custom Raised Panel Sizes

1/8"

1/8"

1/4"

Upper Panel

 

18 3/16"

 

 

 

1"

 

 

 

 

 

 

 

 

 

 

 

Shaded area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23 9/16"

 

 

1/8"

 

 

 

 

 

can only be 3/8"

 

 

 

 

 

thick max.!!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/16"

 

 

 

 

23 11/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lower Panel

 

 

 

 

4 5/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/16"

 

 

 

 

 

 

3/16"

3/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(not to scale)

Trim Kit DAX1000AXX is required for the procedure.

Raised door panels, typically Wood, have a maximum thickness of 3/8" along the lower 1" of door panel as shown in the shaded portion of drawing. This is done to prevent the panel from contacting with the access panel when dishwasher door is opened.

Thick wood panels should be 1/4" thick. For panels more than 1/4" thick, the outer edge will need to be routered as shown in drawing.

When applying a 3/4" raised panel to 1/4" backing, there must be a 5/16" clearance on side of 1/4" backing. This clearance allows the panel to slide into the flange.

Wood panels need a waterproof protective finish applied to all sides and edges of panels.

Maximum panel weight is 11 1/2 pounds with booster spring (Provided with the DAX1000AXX).

Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.

Copyright © Dimension Express, 2002.

149

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN130.61 • A307B149 • • 032603 • 95655 • 19743

associated with reusing old Data Sheets.

Loading...