Jenn-Air JBC7624BS Installation Manual

INSTALLATION INSTRUCTIONS
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10629089B
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
24" (59.5 CM) BUILT-IN COFFEE SYSTEM
INSTRUCTIONS D'INSTALLATION
SYSTÈME INFUSEUR À CAFÉ INTÉGRÉ DE 24" (59,5 CM)
Table of Contents/Table des matières
BUILT-IN COFFEE SYSTEM SAFETY ..........................................1
INSTALLATION REQUIREMENTS................................................2
Location Requirements................................................................2
Electrical Requirements ...............................................................3
INSTALLATION INSTRUCTIONS..................................................4
Install the Mounting Brackets ......................................................4
Install the Coffee System .............................................................5
Complete Installation ...................................................................6
BUILT-IN COFFEE SYSTEM SAFETY
SÉCURITÉ DU SYSTÈME INFUSEUR À CAFÉ INTÉGRÉ...........7
EXIGENCES D’INSTALLATION.....................................................8
Outillage et pièces........................................................................8
Exigences d’emplacement...........................................................8
Spécifications électriques ............................................................9
INSTRUCTIONS D’INSTALLATION.............................................10
Installation des platines de montage .........................................10
Installation du système infuseur à café......................................11
Achever l’installation ..................................................................12
INSTALLATION REQUIREMENTS
†®TORX and T20 are registered trademarks of Saturn Fasteners, Inc.
A
B
CD
E
F
G
23³⁄₈"
(59.5 cm)
18"
(45.5 cm)
15⁵⁄₈"
(39.8 cm)
¹³⁄₁₆"
(2.1 cm)
20¹¹⁄₁₆
"
(52.8 cm)
14
³⁄₈
"
(36.1 cm)**
14⁹⁄₁₆"
(37.2 cm)
¹¹⁄₁₆
"
(1.9 cm)
15
¹⁄₄
"
(38.0 cm)*
Tools and Parts
Tools Needed
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Measuring tape
Pencil
Level
Masking tape
T20
Drill
⁵⁄₆₄" (2 mm) drill bit
®†
Torx®† screwdriver
Parts Supplied
All of the following parts are provided, but some parts may not be used. The location of your coffee system installation will determine which parts you will use.
Refer to installation instructions for cutout dimensions for any
appliances installed above or below the built-in coffee system.
IMPORTANT: To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This coffee system has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperature of 194°F (90°C).
Product Dimensions
A. Mounting brackets/runners (2) B. Metal trim piece (1) C. Bracket spacers (4) (2 - 1 mm thick;
2 - 2 mm thick)
D. Power supply cord clip (1)
E. 4.5 x 16 mm
T20 screws (19)
F. 4.2 x 9.5 mm
T20 screws (4)
G. Leveling spacers (8)
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with coffee system.
The built-in coffee system must be installed in cabinetry with
the dimensions provided.
Follow the installation instructions for any cabinetry used to
house the built-in coffee system. Make sure cabinet is securely attached to the wall.
Follow the installation instructions
Recessed installation area must provide complete enclosure
Grounded electrical supply is required. See “Electrical
around the recessed portion of the coffee system.
Requirements” section.
*From front of coffee system cavity to back of electrical box.
**From front corner to rear corner of coffee system cavity.
2
Cabinet Dimensions
22"
(56 cm)
21⁷⁄₁₆"
(54.5 cm)
min.
17¹³⁄₁₆"
(45 cm) min.
33⁷⁄₁₆"
(85.0 cm)
min.
G
A
B
C
E
D
F
15¹⁄₈"
(38.2 cm)
14³⁄₈"
(36.1 cm)
17⁵⁄₈"
(44.8 cm)
15¹⁵⁄₁₆"
(40.1 cm)
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Cutout Top View
Electrical Requirements
IMPORTANT: The coffee system must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this coffee system be provided.
Check that the outlet provides 120-volt power and is correctly
grounded.
A. Coffee system B. Non-flush receptacle C. Flush receptacle
E. Non-flush receptacle located in upper
right or upper left corner
F. Wall behind cabinet
G. Coffee system with runners fully extended
D. Back of cabinet
3
INSTALLATION INSTRUCTIONS
A
B
B
A
A
A
Install the Mounting Brackets
1. Determine where the mounting brackets will be installed and
mark 8 holes through each mounting bracket onto the side cabinet.
IMPORTANT: The front of the mounting bracket must be flush with the outside of the cabinet frame.
NOTE: To accommodate for flush installation with certain custom cabinets, align the front of the mounting brackets ¹³⁄₁₆" (2.1 cm) back from the front of the cabinet.
4. Using a 2 mm drill, drill the holes marked in Step 1.
5. Secure the mounting brackets to the side cabinets with eight
4.5 x 16 mmscrews in each bracket.
6. Remove the tape holding the brackets in place.
7. Pull the runners forward until they are fully extended and in
the locked position. Place level across the runners and check levelness. Then place the level along the length of each runner and check levelness from front to back. If the runners are not level, uninstall the mounting brackets and raise or lower the mounting brackets as necessary until they are level.
A. Front of mounting bracket flush
with outside of cabinet frame
B. Mark 8 screw holes.
2. With the mounting brackets held or taped in place, measure
the distance between the two brackets. (Do not measure between the runners.) The distance should be 21¹¹⁄₁₆" (55.1 cm).
NOTE: If the distance between the mounting brackets is greater than 21¹¹⁄₁₆" (55.1 cm), bracket spacers will need to be used. Two 2 mm bracket spacers and two 1 mm bracket spacers are included. See Step 3.
3. If bracket spacers are needed: Position the necessary
spacer(s) behind the mounting brackets. Continue with Step 4.
8. If the coffee system is being installed above a wooden
cabinet bottom, use two 4.5 x 16 mm screws to install the metal trim piece at the front edge of the cabinet bottom.
A. Metal trim piece
A. Bracket spacers
4
Loading...
+ 8 hidden pages