HEAVY FOG GLACIATOR
HEAVY FOG GLACIATOR
Fluids Suitable for this system:
Heavy Fog Fluid B2
Heavy Fog Fluid C3
CONNECTIONS
REMOTE
1-GND, 2-12V OUT, 3-INPUT
1
INTERFACE
569
DMX ADDRESS
1 GND 2 COLD 3 HOT
OUT
IN
ON
1 FOG 2 STANDBY 3 TIMER 4FAN 5 SPECIAL 6 GND
1
1
2
2
4
3
8
4
16
5
32
6
64
7 8
128
9
256
10
SPECIAL 1
11
SPECIAL 2
12
SPECIAL 3
INPUT
FUSE RATINGS
The Heavy Fog Glaciator uses four fuses. They should be replaced with the value and type detailed below:
DMX receiver low voltage
2AT
Power PCB
12AT
Compressor control relay
12AT
Main input fuse
20AT
Three of these fuses are located internally and should not be accessed without first disconnecting the power supply.
FILTERS
The Heavy Fog Glaciator uses a washable synthetic fibre filter in the air intake for the condenser unit (located at the top of the machine). This can be removed for cleaning by removing the ventilation grill above it (two M5 screws). Use
DMX DATA
the following guidelines for when to check the filter.
Normal Conditions
: Inspect and clean/replace every 250 hours
Severe Conditions
: Inspect and clean/replace every 150 hours
17
HEAVY FOG GLACIATOR
USER GUIDE
HEAVY FOG GLACIATOR
USER GUIDE
SPECIFICATION
HEAT EXCHANGER
2.5KW heater (240V) Wide bore steel vaporizing coil Ceramic thermal trip for over-temperature protection Electronic Temperature control using thermocouple
FLUID SYSTEM Oscillating piston high pressure fluid pump Low fluid detection by electronic sensor
9.5L fluid containers (2.5 US Gal.) Maximum fluid consumption 120mL/minute
REMOTE CONTROL OPTIONS
DMX512 decoder:
Required Channels = 2 Output is proportional for all levels above 12% Channels supported=1to511 Valid start codes = 0 (dimmer data only)
Full framing error detection implemented Analogue control via standard JEM Multifunction Contoller. Optional PLC interface for simple switching control of the system.
CONTROL PANEL
2 x LED displays with 4 button keypad Output level control from 0 to 100% for Fog Timer range:
Delay time (toF) 0 seconds - 90 seconds
Run time (ton) 0 seconds - 90 seconds
USER GUIDE CONTENTS
Introduction 2
Features 2
Safety Guidelines 3
Machine Layout 4
Commissioning The Machine 5
Remote Control Options 5
DMX Operation 6
The Display 8
Control Panel Functions 10
The Timer 11
Basic Operation 12
The Fluid System 13
Display Messages 14
Basic Fault Finding 15
REFRIGERATION UNIT 2/3 HP compressor with thermostatic control Uses refrigerant R404A (0.850 Kg)
OUTPUT CONNECTION
Ducting adaptor to accept 150mm (6”) flexible ducting
POWER REQUIREMENTS
Input voltage 200 - 250vac Input power (max) 3.1Kw Main fuse 20AT Frequency 50/60Hz dependant on model.
16
Specification 16
Connections 17
Fuse Ratings 17
Filter Maintenance 17