ADDITIONAL INSTALLATION REQUIREMENTS
for Fire-Rated Doors (JII111)
Fire-rated doors are certied according to independent standards as indicated on the permanent re certication label afxed to each door. To
maintain the validity of this certication, the door installer must follow all of the standard installation instructions as well as comply with the
following requirements.
Edge Seals and Gaskets
Building codes adopted in local areas may require the application of additional edge seals and/or gaskets. The following chart is provided for
your convenience; consult your local building code ofcial (or authority having jurisdiction) for applicable building codes and regulations.
Steel Fire Door (wood edged)
20-min rated
UL 10 (b) - Neutral
Pressure Doors
UL 10 (c) - Positive
Pressure Doors
UBC 7-2 (97) Part
2 - Smoke and Draft
Control Doors
CAN/ULC S104 (Canada) Category H gasket is required. No edge seal is required.
Vision Panel
Vision panels are permitted in all re doors (except wood-edged steel doors) using a listed and labeled light kit. To ensure a proper gasket seal,
vision panels must be installed to lie on a at surface of the door; do not cut across proles when positioning a light kit. The rating of the light
kit, in minutes, must coincide with the rating of the re door. Light kits must be installed per manufacturer’s installation instructions.
Frame
The door slab must be installed in a re rated frame to match installed door. The frame must have a minimum re-rating equivalent to the
rating of the door. Frames must be installed plumb, square and level. Follow frame manufacturer's installation instructions.
Clearances
Clearances between the steel door edge and the frame must be at least 1/16 inch and no greater than 3/16 inch at the header and jambs. Other
re door clearances must be at least 1/16 inch and no greater than 1/8 inch. Trimming is not allowed in the eld unless allowed by NFPA 80
standard.
Latch
Fire rated latch-sets that t the latch cut-out per hardware template are required. Follow the latch manufacturer’s installation instructions.
Closer
Listed surface mounted door closer may be installed using through bolts. Backer plate is recommended. If wood screws are the desired fastener,
appropriate blocking must be manufactured in the door construction. Follow the closer manufacturer’s installation instructions.
General
Frame, hinges, passage sets, and hardware must be re rated and installed in accordance with manufacturer's installation instructions and NFPA
80 standard. Surface mounted hardware must be attached with through bolts unless inner blocking is provided.
No edge seal or gasket is required
for doors with re label code
“D2ON-BS.” Category H gasket is
required for doors with re label
code “D2ONH-BS.”
N/A (a) Category G edge seal must
N/A Category H gasket is required. In addition to Category G edge seal,
Steel Fire Door (steel edged)
20/45/60/90-min rated
Category H gasket is required. No
edge seal is required.
be installed on the door edge
or frame and Category H gasket
must be installed on the frame
per manufacturer's installation
instructions, or
(b) Gasket which is eligible for both
Category G and H can be installed in
lieu of (a) above, or
(c) Pemko S88 or S52 can be installed
in lieu of (a).
Other Fire Doors (ush, stile & rail,
custom carved or molded wood, and
berglass doors)
20/45/60/90-min rated
Category H gasket is required for
exterior doors. No edge seal or
gasket is required for interior doors.
Category G edge seal must be
installed on the door edge or frame
per manufacturer's installation
instructions. Category H gasket is
required for exterior doors.
Category H gasket must be installed
on the frame per manufacturer's
installation instructions.