Introduction
The DCP pumps are carefully inspected and tested to ensure both safety and operating
performance. However, failure to follow the instructions and warnings in this manual
may result in the pump’s damage and/or serious injury. Be sure to read and save this
manual for future reference.
Pump Features
● High performance with innovative motor and energy saving up to 65%
● super quiet operation.
● IC electronic detection, automatic power-off protection if no water.
● No-copper element.
● Suitable for both marine and fresh water
● Rust free. With anti-resistant ceramic shaft, Longer operation file.
Controller Features
● Adjustable flow rate.
● “Feed” Mode – pauses pump for 10 minutes and then restarts
● Memory function – after power off ensures that the pump retains parameter
settings.
Control and Panel Function
1. LED display and controller key Instructions
The LED display indicates the power/speed setting/fault codes - the key panel is touch
controlled.
2. Operating instructions
The pump must be connected with the controller and the 24V or 36V power adaptor
correctly before use.
Lock / unlock function:
Press the "+" or "-" button for three seconds until the LED light flashes twice, the
controller is locked; Similarly, press the "+" or "-" button for three seconds until the
LED indicator light flashes twice, the controller is unlocked
Feed Function:
When the pump is running, press "II" button, pump stops working, the "10min"
indicator lights up. The pump re starts automatically at previous settings after 10
minutes. Or you can press the “II” button at any time to make the pump re start.
Normal Operation:
After connecting the pump, the controller is set as per the last setting (memory
function). Touch the “II” button and the pump will stop working, and Feed indicates in
LED. Touch “II” button again, and the pump will resume working. Normal operating
mode is with PXXX shown on LED (P is short for power). There are 71 settings for
speed. When touching up/down buttons, the LED will indicate the current speed setting
(FXX). You can set speed ranging from 30% to 100% in 1% increments. After more
than 1 second with no press of the +/- button, the display will revert to Watts display