Jebao DCP-2500, DCP-8000, DCP-10000, DCP-6500, DCP-3000 Owner's Manual

...

DC Pump

OWNER’S MANUAL

DCP-2500,DCP-3000,DCP-4000,DCP-5000,DCP-6500, DCP-8000, DCP-10000 DCP-15000,DCP-18000,DCP-20000 Introduction
Pump Features
High performance with innovative motor and energy saving up to 65%
super quiet operation.
IC electronic detection, automatic power-off protection if no water.
No-copper element.
Suitable for both marine and fresh water
Rust free. With anti-resistant ceramic shaft, Longer operation file.
Controller Features
Adjustable flow rate.
“Feed” Mode – pauses pump for 10 minutes and then restarts
Memory function – after power off ensures that the pump retains parameter
settings.
Control and Panel Function
1. LED display and controller key Instructions
The LED display indicates the power/speed setting/fault codes - the key panel is touch controlled.
2. Operating instructions
The pump must be connected with the controller and the 24V or 36V power adaptor correctly before use.
Lock / unlock function: Press the "+" or "-" button for three seconds until the LED light flashes twice, the controller is locked; Similarly, press the "+" or "-" button for three seconds until the LED indicator light flashes twice, the controller is unlocked
Feed Function:
When the pump is running, press "II" button, pump stops working, the "10min" indicator lights up. The pump re starts automatically at previous settings after 10 minutes. Or you can press the “II” button at any time to make the pump re start.
Normal Operation:
After connecting the pump, the controller is set as per the last setting (memory function). Touch the “II” button and the pump will stop working, and Feed indicates in LED. Touch “II” button again, and the pump will resume working. Normal operating mode is with PXXX shown on LED (P is short for power). There are 71 settings for speed. When touching up/down buttons, the LED will indicate the current speed setting (FXX). You can set speed ranging from 30% to 100% in 1% increments. After more than 1 second with no press of the +/- button, the display will revert to Watts display (PXXX).
Power save mode
Turn on the power - after more than 25 seconds with no touch to the control buttons, the LED brightness will reduce; the led returns to normal brightness when any button is pressed.
Dry Running Automatic shut off: If pump runs dry for 2 minutes, the pump will automatically shut off. To restart, disconnect the power and re connect power.
3. Error code and description
The LED will display a flashing error code when a fault is detected. Error code explanation is as below:
Er01: Abnormal Working current - Check if the pump power adapter is functioning correctly or broken. Er02: Controller overheating - Check if the controller exposed to the direct sunshine or is in a high temperature environment.
Er03: Pump idling – Check if the pump is working dry. Er04: Impeller stops running - Check if the impellor is dirty or jammed. Er05: Abnormal Working voltage. Check the input supply voltage.
Note: for indoor use, the power socket must be installed with the leakage current
protecting device, and the leakage current shall not exceed 30mA.
Performance Parameters Table
No:
Model No:
Voltage
Control box (W)
Consumption
(W)
Flow rate
(L/H)
Head Max (M)
1
DCP-2500
DC 24V
DCP-2500
23
2500
2.5
2
DCP-3000
DC 24V
DCP-3000
25
3000
3.0
3
DCP-4000
DC 24V
DCP-4000
32
4000
4.0
4
DCP-5000
DC 24V
DCP-5000
40
5000
4.0
5
DCP-6500
DC 24V
DCP-6500
55
6500
4.5
6
DCP-8000
DC 24V
DCP-8000
65
8000
5.2
7
DCP-10000
DC 24V
DCP-10000
80
10000
6.0
8
DCP-15000
DC 24V
DCP-15000
105
15500
7.0
9
DCP-18000
DC 36V
DCP-18000
130
18000
9
10
DCP-20000
DC 36V
DCP-20000
165
20000
9.5
WARNING
Do not connect to any power supply over the rated voltage Do not immerse the pump in the flammable liquid. Do not use the pump in the water temperature above 35℃. Maximum water depth 1.5M Maximum head - please see the parameter table. Do not immerse the plug/connectors into water or any other liquid. This appliance is not allowed to use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
CAUTION
Always disconnect the pump from the power supply before cleaning, maintenance and handling.
Do not let the pump work dry. Do not lift the pump by holding the power cord only Do not use the pump in heated liquid. The pump is suitable for both fresh water and sea water The pump can used submersed or externally (non-submersed) – the pump housing must be primed with water. The pump is not suitable for use in swimming pools.
General
A clogged or dirty intake screen will reduce the pump performance. If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris contacting the intake.
Do not let the pump run dry. Place pump into water before powering on. Initially the pump may not work due to air in the pipe work If this is the case, please power off and on several times and this will help prime the pump.
Loading...