JCM RContactR User Manual

RCONTACT R
User’s Manual
Introduction
The system is designed for applications where pedestrian doors installed on garage doors. Is a position detection system of the pedestrian door status, so that if it is open the system prevents the start of the movement of the garage door. Is a wireless system composed by one transmitter and one receiver. The receiver monitors the status of transmitters connected to it.
The system complies with EN ISO 13849-1, category 2, PLc.
Technical data
Frequency 869,50 MHz Power supply 12/24V ac/dc (9-35V dc / 8-28V ac) Consumption standby/operating 18mA/80mA Memory 6 transmitters (3 on relay 1, 3 on relay 2) Relay numbers 2 relays Relay contacts 1A Radiated power < 1mW Operating temperature -20ºC - +85ºC Seal IP54 (with IP65 cable glands) Box size 82 x 190 x 40mm Range 50m
Starting up
Mechanical installation
Fix the back of the box to the wall, using the wall plugs and screws supplied. Install the receiver, close to the door and avoid metal surfaces between the receiver and the transmitter. Pass the cables through the bottom of the receiver. Connect the power cables to the terminals of the printed circuit, following the indications of the connections diagram. Store the transmitter on the receiver. Fix the front of the receiver to the back with the screws supplied for the purpose.
Programming the transmitter on the receiver
While programming the receiver, press the PROG button on the transmitter to be programmed into the receiver. The receiver allows programming 6 transmitters (3 for Relay 1 and 3 for Relay 2). Each safety edge transmitter must be learnt into the appropriate channel of the safety edge receiver.
1248086_Rev1.0RCONTACTR Page1/3
Mode Configuration of transmitter programming in the receiver.
1 When you open the pedestrian door, relay 1 on the receiver will be activated
Led R1 Led R2
ON OFF 2 When you open the pedestrian door, relay 2 on the receiver will be activated OFF ON 3 When you open the pedestrian door, the two relays will be activated at the same time ON ON
PRESS RPORG BUTTON LED TURNS ON PRESS TRANSMITTER PROG ONE BEEP & PROGRAMMED
PRESS RPROG BUTTON LED TURNS OFF & END PROG
Autotest signal
Check the autotest output on the control panel, in stanby, to see whether the voltage is 0V (positive polarization) or 12/24V ac/dc (inverted test input). Switch on the autotest signal of the panel and check that it has a maximum duration of 3 seconds.
Autotest output
Connection to a equipment with autotest
Connection to a equipment without autotest **
* Nota: Connect autotest only for used outputs. ** Where the autotest is not used, the system is not checked at the start of the operation, which means that security standard EN 12453 regarding the use of motorised garage doors is, in some cases, not complied with..
in standby
0V 12/24V
12/24V 0V Inverted ON Connected* Connected*
--- --- --- OFF Not connected Not connected
Autotest output activated
Polarization type
Positive
Jumper ATEST POL
OFF
ATEST1 ATEST2
Connected* Connected*
Maintenance
Beeps and leds messages / errors indication table
B1/B2 Led
ON OFF No beeps RCONTACT R Detection of pedestrian door at open state
OFF OFF 4 beeps each
OFF ON No beeps RCONTACT R Check function. See coverage and signal quality
System Check
This function has to be used to check the operation and range of all the devices once the installation has been carried out. Press the receiver’s CHECK button for at least 1 second to enter check mode. The indicator light will come on and four beeps will be heard. Perform a complete door opening and closing manoeuvre. During the system check a beep will be heard every 1,5 seconds.
1248086_Rev1.0RCONTACTR Page2/3
Check Led
Beeps Equipment Message / error Solution
RCONTACT transmitter not programmed Verify if it must be programmed and perform the
Communication failure between RCONTACT R and RCONTACT T
RCONTACT R RCONTACT/T low battery Verify the batteries of the transmitter
20 seconds
table.
---
programming. Verify the batteries of the emitter and if they are charged, verify the radio signal with the Check function.
---