COD. 1248054-GB / 1.1
MOTION: 868,35MHz
RADIOBAND1G: 868,90MHz
High security rolling code
RBMOT30: 30 codes / RBMOT500: 500 codes
RADIOBAND1G: Ex. 6 RADIOBAND/TBX (3 on relay 1, 3 on relay 2)
9-24 / 21-35V dc
8-16 / 15-28V ac
MOTION: 2 relays (R1 and R2)
RADIOBAND1G: 2 relays (B1 and B2)
RBMOT30: 18mA / 115mA / RBMOT500: 22mA/244mA
2 0/12/24V AC/DC inputs with selectable polarity
MOTION: 100m
RADIOBAND1G: 10m
RBMOT30 / RBMOT500
GENERAL DESCRIPTION
This equipment consists of 30 or 500 codes MOTION receiver and receiver to RADIOBAND 1G
system.
TECHNICAL CHARACTERISTICS
COD. 1248054-GB / 1.1
TWO SAFETY EDGES CONNECTION WITH
NEGATIVE POLARIZATION AUTOTEST
CONTROL PANEL
RBMOTION
R1 desactivated, state by default
Every 5 seconds, correct supply of the
equipment
Relay R2 Activation/
Indicates if the transmitter
has low battery
R2 desactivated, state by default/
Indicates if the transmitter„s battery is
working properly
Every 5 seconds, correct supply of the
equipment
Relay B1 Activation or
band not connected
B1 desactivated, correct safety edge
state
Relay B2 Activation or
band not connected
B2 desactivated, correct safety edge
state
Coverage (See CHECK funcftion)
RBMOT30 / RBMOT500
INSTALLATION AND CONNECTIONS
Attach the rear part of the housing to the wall using the plugs and screws supplied. Pass the cables
through the bottom of the receiver. Connect the power cables to the terminals marked in the mother
board, as indicated. Install the receiver, close to the door and avoid metal surfaces between the
receiver and the transmitter RADIOBAND. Pass the cables through the bottom of the receiver.
Program transmitters and transmitters RADIOBAND as programming section. Fix the front of the
receiver to the back with the screws supplied for the purpose.
1- Power supply 12/24V AC/DC: (+)
2- Power supply 12/24V AC/DC: (-)
3,4- R1: Connection to the safety band input of the control panel (resistive contact 8.2k) with
jumper in position BS1. Or to the control panel safety contact input (NC) with jumper in position CS1.
5,6- R2: Connection to a second safety band input of the control panel (resistive contact 8.2k) with
jumper in position BS2. Or to the control panel safety contact input (NC) with jumper in position CS2.
7- AUTOTEST: Common connection safety self-test (-). See Figure and table POLARIZED SELF-TEST.
8- AUTOTEST: Self-test connection for R1. See Figure and table POLARIZED AUTO-TEST.
9- AUTOTEST: Self-test connection for R2. See Figure and table POLARIZED AUTO-TEST.
10, 11- R1: Relay 1 output RADIO receiver
12, 13- R2: Relay 2 output RADIO receiver
LIGHT INDICATORS
COD. 1248054-GB / 1.1
Configuration of transmitter programming in the receiver.
Standard Programming (default option,
the receiver is always configured on pluri-channel)
The relays are activated 1st relay by channel 1
and 2nd relay by channel 2 (3rd relay by channel 1
and 4th relay by channel 2)
By pressing any transmitter channel,
relay 1 on the receiver will be activated
By pressing any transmitter channel,
relay 2 on the receiver will be activated
By pressing any transmitter channel, the two relays
will be activated at the same time*
Turned on. It indicates the channel to program.
Turned on. It indicates the channel to program.
RBMOT30 / RBMOT500
OPERATING
The pilot lights are activated every 5 seconds to indicate the correct supply of power to the
equipment.
Upon receiving a code, the receiver checks whether it is in its memory, activating the corresponding
relay R1 and/or R2. The relay activation mode is selected in either impulse or ON/OFF using the
Imp/Bies jumper (only with the relay 2). For adjustment of relay 1, see manual of the programming
tool.
The receiver checks that all the programmed bands are working properly. If a band is activated or if
there is an error in its operation, the receiver activates the appropiated B1 or B2 output relay and
the appropiated B1 or B2 light indicator turns on.
PROGRAMMING
MANUAL PROGRAMMING OF MOTION TRANSMITTERS
Press the receiver programming button for 1 sec. and an acoustic signal will be heard. The
receiver will enter standard programming (see table). If the receiver programming button is
held pressed down, the receiver Hill enter special programming, cyclically passing from one
configuration to the next. Once the programming configuration for the transmitter to be
registered has been chosen, send the code to be programmed by pressing the transmitter.
Every time a transmitter is programmed, the receiver will issue an acoustic signal for 0.5
sec.
*If working in ON/OFF activation mode, relay 1 will act as impulse and relay 2 as ON/OFF. Therefore, on the first
press relay 1 will close and open the contact and relay 2 will only close. On the second, relay 1 will close and
open the contact and relay 2 will open.
N.B.: Each transmitter can be configured independently on the receiver.
MANUAL PROGRAMMING OF RADIOBAND TRANSMITTERS
Makes it possible to store 6 RADIOBAND transmitters (3 Relay B1 and 3 on Relay B2).
Press the receiver programming PROG button for 1s; a sound signal will be heard. The
receiver will enter safety band closing programming mode (BSC). If the programming button
is kept pressed, the receiver will enter safety band opening programming mode (BSO),
moving cyclically from one really to another. Once the programming relay has been chosen
for the transmitter you want to start using, send the programming code by pressing the
RADIOBAND transmitter. Every time a transmitter is programmed, the receiver will emit a
sound signal for 0.5s.