JCM Rband TC User Manual

COD. 1248044 / 1.2
RBAND TC
GB
INTRODUCTION
DESCRIPTION
Up to three transmitters per output can be connected to the receiver. There are two outputs on each receiver. The system is compatible with 8K2 monitored safety edges or electromechanical safety edges (volt free safety contacts NC).
There is also a Vbat auxiliary power input to power the transmitter through the RB-BATPACK providing more operational autonomy.
The system complies with EN ISO 13849-1.
USE OF THE SYSTEM
This equipment is designed to be installed with a safety edge for door and gate installations. It is not guaranteed for directly activating equipment other than that specified. The manufacturer reserves the right to change the specification of the equipment without prior warning.
TECHNICAL CHARACTERISTICS
Frequency 868.90MHz Power supply 3V DC (2 x 1.5V LR6 AA) Operating consumption 12mA Radiated power < 25mW Operating temperature -20ºC - +55ºC Watertighness IP44 Size 40 x 194,5 x 20mm Range 10m Battery life (aprox) 2 Years Minimum time between two activations of RADIOBAND (to comply with the R&TTE Directive)
7 min
INSTALLATION AND WIRING
MECHANICAL INSTALLATION
Swipe the front cover following the indication of the box to open the equipment. Fix the back of the box to the door. Install the transmitter following the technical manual and avoid placing metallic surfaces between the receiver and the transmitter. Pass the cables through the holes indicated. Connect the safety edge following the electrical connections clause and ensure that the safety edge keeps totally waterproof. Swipe the front cover to the back to close the equipment.
1
COD. 1248044 / 1.2
RBAND TC
HOLE FOR WIRES
TERMINALS
PROGRAMMING BUTTON
BATTERIES
-
REMOVABLE PLASTIC
+
A
A
A
A
-
+
8k2 MONITORED SAFETY EDGE CONNECTION
Connect the safety edge to the S.EDGE terminal. Electromechanical safety edges with 8k2 output are also considered 8k2 monitored safety edges.
8k2
Sedge Detection Sedge Ok Sedge Open
0k - 5,8k
ΩΩ
7k - 9k
ΩΩ
11k - k
Ω∞Ω
VOLTAGE FREE CONTACT CONNECTION
When a voltage free contact is to be connected, (eg. photocells or electromechanical safety edges without resistive output), connect it to the SEC terminal.
Note: In order to comply with the EN 12453 safety standard for the use of motorized garage doors, the device connected to this
input must have some verification system to ensure its proper functioning.
2
COD. 1248044 / 1.2
RBAND TC
OPERATING
The receiver checks that all the safety edges programmed are operating correctly. In case of activation of a safety edge or error in the operation, the receiver activates the output relay.
PROGRAMMATION
While programming the receiver, press the PROG button on the transmitter to be programmed into the receiver. The RADIOBAND-RU allows programming 6 RBAND TC (3 for Relay 1 and 3 for Relay 2).
Each safety edge transmitter must be learnt into the appropriate channel of the safety edge receiver.
Mode Configuration of transmitter programming in the receiver. Led R1 Led R2
1 By pressing the transmitter, relay 1 on the receiver will be activated ON OFF 2 By pressing the transmitter, relay 2 on the receiver will be activated OFF ON 3 By pressing the transmitter, the two relays will be activated at the same time ON ON
Note:
- A Transmitter should only be connected to one receiver.
If 10 seconds pass without programming a transmitter, the receiver will exit the programming mode. If when programming a transmitter the receiver’s memory is full then it will emit 7 beeps of 0.5 sec and exit the programming mode.
3
COD. 1248044 / 1.2
RBAND TC
MAINTENANCE
TRANSMITTER BATTERY LOW INDICATOR
If the battery of a transmitter programmed into the receiver becomes low, the receiver will beep 4 times every 20 seconds. If there is more than one transmitter programmed, each safety edge should be activated to identify, hearing the 4 beeps, which transmitter has a low battery. If the battery power is low, replace it immediately.
REPLACING THE TRANSMITTER BATTERY
Remove the box cover. Replace the two used batteries with new ones, taking into account the polarity indicated by the connector. Check that the new batteries support the same temperature range as those they are replacing.
IMPORTANT ANNEX
Disconnect the power supply whenever you proceed to the installation or repair of the control panel. In accordance with the European low voltage directive, you are informed of the following requirements:
· For permanently connected equipment, an easily accessible connection device must be incorporated into the cabling.
· This system must only be installed by a qualified person that has experience with automatic doors/gates and knowledge of the relevant EU standards.
· The instructions for use of this equipment must always remain in the possession of the user.
· Terminals with a maximum section of 3.8mm2 must be used to connect the cables.
· The frequency of the RadioBand system does not interfere in any way with the 868 MHz remote control systems.
JCM TECHNOLOGIES, S.A. declares herewith that the product RBAND TC complies with the requirements of the 1999/5/ CEE R&TTE Directive, 2004/108/EC Directive on electromagnetic compatibility and 2006/95/EC on low voltage, insofar as the product is used correctly.
CE CONFORMITY DECLARATION
See web www.motion-line.com
4