• INTRODUCTION
DESCRIPTION
The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is
used. The system provides a wireless system replacing spiral cables or energy chain systems to provide the safety
signal to the door or gate control panel. The receiver monitors the status of transmitters connected to it.
Up to three transmitters per output can be connected to the receiver. There are two outputs on each receiver. The
system is compatible with 8K2 monitored safety edges and volt free safety contacts.
The system complies with EN ISO 13849-1.
USO OF THE SYSTEM
This equipment is designed to be installed with a safety edge for door and gate installations. It is not guaranteed for
directly activating equipment other than that specified.
The manufacturer reserves the right to change the specification of the equipment without prior warning.
• TECHNICAL CHARACTERISTICS
Frequency Multifrequency system (433 MHz, 868 MHz)
Power supply 3V DC (2 x 1.5V LR6 AA)
Operating consumption 12mA
Radiated power < 25mW
Operating temperature -20ºC - +55ºC
Watertighness IP22
Size 40 x 194,5 x 20mm
Range (guaranteed) 10m
Battery life (aprox) 2 year
• INSTALLATION PROCEDURE AND BASIC WIRING
HOLE
FOR WIRES
TERMINALS
PROGRAMMING
BUTTON
JUMPER “O”
BATTERIES
1
REMOVABLE
PLASTIC
COD. 1248061 / 1.0
RBAND/OS GL
MECHANICAL INSTALLATION
Swipe the front cover following the indication of the box to open the equipment. Fix the back of the box to the door. Install the
transmitter following the technical manual and avoid placing metallic surfaces between the receiver and the transmitter. Pass the
cables through the holes indicated. Connect the safety edge following the electrical connections clause and ensure that the safety
edge keeps totally waterproof. Swipe the front cover to the back to close the equipment.
8K2 MONITORED SAFETY EDGE CONNECTION
Connect the safety edge to the S.EDGE terminal. Electromechanical safety edges with 8k2 output are also considered 8k2
monitored safety edges.
VOLTAGE FREE CONTACT CONNECTION
When a voltage free contact is to be connected, (eg. photocells or electromechanical safety edges without resistive output), connect
it to the SEC terminal.
Note: In order to comply with the EN 12453 safety standard for the use of motorized garage doors, the device connected to this
input must have some verification system to ensure its proper
functioning.
OPTO SAFETY EDGE CONNECTION
The use of opto safety edges requires the autotest signal or the current detector signal from the receiver.
Ensure the safety edge selection jumper is fitted in the O position.
The system is only compatible with low power opto transmitter/receiver (3Vdc / 3mA).
The opto safety edge remains in standby mode (non functioning) until it receives an activation signal from the receiver. The
activation signal is sent during the auto-test and it enables the opto safety edge for 60 seconds (by default) to allow the full
travel of the door/gate.
When using the current detector signal instead of autotest, the opto safety edge will remain active during the motor movement.
The activation time of the opto safety edge can be modified. Before doing this operation it is necessary to know the door travel
time.
1. Press the receiver PROG and CHECK buttons simultaneously until the three CHECK, B1 and B2 leds go light on.
2. Press the PROG button to begin the memorisation of the time the opto safety edge will be activated. You will hear a
beep each second, to count the time easier.
3. Press the PROG button another time to memorise the total time the opto safety edge will be activated.
4. Program the transmitter to the receiver again (see paragraph PROGRAMMING).
The auto-test signal is needed to work with the opto safety edge.
AUXILIARY INPUT CONNECTION
When programming in the receiver the Mode 4 (See PROGRAMMATION clause), an auxiliary input turns available on the
transmitter. The transmitter transmits the status of auxiliary input to the second relay of the receiver. This auxiliary input is a
normally open contact and it will be programmed always in the relay 2 of the receiver.
In case of using an opto safety edge, this auxiliary input will be on the BS terminal.