• INTRODUCTION
DESCRIPTION
The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety
edge is used. The system provides a wireless system replacing spiral cables or energy chain systems to provide the safety
signal to the door or gate control panel. The receiver monitors the status of transmitters connected to it.
Up to three transmitters per output can be connected to the receiver. There are two outputs on each receiver. The
system is compatible with 8K2 monitored safety edges and volt free safety contacts.
The system complies with EN ISO 13849-1.
USO OF THE SYSTEM
This equipment is designed to be installed with a safety edge for door and gate installations. It is not guaranteed for
directly activating equipment other than that specified.
The manufacturer reserves the right to change the specification of the equipment without prior warning.
• TECHNICAL CHARACTERISTICS
Frequency Multifrequency system (433 MHz, 868 MHz)
Power supply 3V DC (2 x 1.5V LR6 AA)
Operating consumption 12mA
Radiated power < 25mW
Operating temperature -20ºC - +55ºC
Watertighness IP22
Size 40 x 194,5 x 20mm
Range (guaranteed) 10m
Battery life (aprox) 2 year
• INSTALLATION PROCEDURE AND BASIC WIRING
MECHANICAL INSTALLATION
Swipe the front cover following the indication of the box to open the equipment. Fix the back of the box to the door. Install the
transmitter following the technical manual and avoid placing metallic surfaces between the receiver and the transmitter. Pass
the cables through the holes indicated. Connect the safety edge following the electrical connections clause and ensure that the
safety edge keeps totally waterproof. Swipe the front cover to the back to close the equipment.
1
COD. 1248058 / 1.2
RBAND/B GL
8K2 MONITORED SAFETY EDGE
CONNECTION
Connect the safety edge to the S.EDGE terminal.
Electromechanical safety edges with 8k2 output are
also considered 8k2 monitored safety edges.
VOLTAGE FREE CONTACT CONNECTION
When a voltage free contact is to be connected, (eg. photocells or
electromechanical safety edges without resistive output), connect it
to the SEC terminal.
Note: In order to comply with the EN 12453 safety standard for
the use of motorized garage doors, the device connected to this
input must have some verification system to ensure its proper
functioning.
.
2