COD. 1248033-GB / 1.0
RBAND/UMS - RBAND/CSM
• INTRODUCTION
DESCRIPTION
The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge
is used. The system provides a wireless system replacing spiral cables or energy chain systems to provide the safety signal to
the door or gate control panel. The receiver monitors the status of transmitters connected to it.
Up to three transmitters per output can be connected to the receiver. There are two outputs on each receiver. The system is
compatible with 8K2 monitored safety edges, opto safety edges and volt free safety contacts. Two inputs available in the
transmitter.
The system complies with EN 954-1 Category 2.
USE OF THE SYSTEM
This equipment is designed to be installed with a safety edge for door and gate installations. It is not guaranteed for directly
activating equipment other than that specified.
The manufacturer reserves the right to change the specification of the equipment without prior warning.
• TECHNICAL CHARACTERISTICS
System non compatible with RADIOBAND 1G.
RBAND/UMS RBAND/CSM
Frequency Multifrequency system (433 MHz, 868 MHz) Multifrequency system (433 MHz, 868 MHz)
Memory 6 transmitters (3 on relay 1, 3 on relay 2) 6 transmitters (3 on relay 1, 3 on relay 2)
Relay numbers 2 relays --Power supply 12/24V ac/dc pluggable
Power supply range
Relay contacts 1A 1A
Consumption
standby/operating
Autotest signal input Two 0/12/24V ac/dc inputs with selectable polarity integrated
Radiated power < 25mW < 25mW
Operating temperature -40ºC a +85ºC -40ºC a +85ºC
Seal IP54 (with IP65 cable seals) IP20
Box size 82 x 190 x 40mm 50 x 47 x 14mm
Range 10 metres 10 metres
9-35V dc
8-28V ac
Max 255mA Max 20mA
---
- 1 -
COD. 1248033-GB / 1.0
RBAND/UMS - RBAND/CSM
SAFETY EDGE OR
VOLT FREE CONTACT
SELECTOR
CHECK
BUTTON
POWER
SUPPL
R1 / R2
AUTO TEST
CONNECTION
PROGRAMMING
BUTTON
FREQUENCY
SELECTOR SWITCH
RESET JUMPER
CURRENT DETECTO
CONNECTION
CHECK
BUTTON
PROGRAMMING
BUTTON
FREQUENCY
SELECTOR
SWITCH
CONTROL PANEL
CONNECTION
- 2 -
COD. 1248033-GB / 1.0
RBAND/UMS - RBAND/CSM
• INSTALLATION PROCEDURE AND BASIC WIRING
MECHANICAL INSTALLATION RBAND/UMS
Fix the back of the box to the wall, using the wall plugs and screws supplied. Install the receiver, close to the door and avoid
metal surfaces between the receiver and the transmitter. Pass the cables through the bottom of the receiver. Connect the
power cables to the terminals of the printed circuit, following the indications of the connections diagram. Store transmitters.
Fix the front of the receiver to the back with the screws supplied for the purpose.
INSTALLATION ADVISES
Use the cable entry at the bottom of the receiver for the power supply and control connections.
The transmitter and receiver antenna must be parallel to each other for optimum signal reception.
Fit the batteries ensuring the correct polarity.
After programming the transmitter re-fit the front cover of the transmitter and the receiver.
>20cm
MECHANICAL INSTALLATION RBAND/CSM
Connect to a control panel using a connector for safety devices. The power supply must be disconnected.
OPTIONS SELECTOR
Option No ON OFF
1 – Channel selection See table Multifrequency system See table Multifrequency system
2 – Channel selection See table Multifrequency system See table Multifrequency system
3 – Autotest polarity Negative polarity Positive polarity
4 – Relay 2 function Low battery indicator Normal function
Nota: Options 3 and 4 non available in RBAND/CSM
• ELECTRICAL CONNECTIONS
- 3 -