RB3 R868
In order to comply with the EN 12978:2003 product standard and assure the correct operation of the
User’s Manual GB
Introduction
The RadioBand system is designed of Commercial and Domestic door applications where a safety edge is used. The system provides a
wireless system replacing spiral cables or energy chain systems to provide the safety signal to the door or gate control panel. The receiver
monitors the status of transmitters connected to it. When an obstacle is detected, the RadioBand system puts its output in a safety state,
switching off the receiver relay.
Up to three transmitters per output can be connected to the receiver. There are two outputs on each receiver that can be connected to
the control panel as 8k2 or NC contact.
The system complies with EN ISO 13849-1:2008, category 2, PLd.
The manufacturer reserves the right to change the specification of the equipment without prior warning.
Technical data
Frequency Multifrequency system 868 MHz auto-adjustable (Channel 1:
868,700 -869,200MHz¸Channel 2: 868,000 -868,600MHz;
Channel 3: 869,400 -869,650MHz; Channel 4: 869,400 869,650MHz)
Memory 6 transmitters (3 on relay 1, 3 on relay 2)
Radiated power < 25mW
Range (in open field) 50 m
Reaction time (typical) 35ms
Maximum reaction time
220ms
system, it is mandatory to follow the instructions below, to avoid serious dangerous to persons.
· SW1:1 is allowed to be set at ON, only if the door cycle is between 7s and 30s.
· SW1:1 is allowed to be set at OFF, only if the door cycle is greater than 30s.
Note: If the door cycle is smaller than 7s, this system must not be used.
1248081_Rev2.0 RB3 R868 Page 1/3
Connection
Mode Configuration of transmitter programming in the receiver.
1 Safety edge activates relay 1 on the receiver
es relay 2 on the receiver
ge in IN1 activates relay 1 and safety edge in IN2 activates relay 2
Starting up
Installation
Programming transmitter to receiver
Before programming, place the options selectors in the desired position. Any subsequent changes will entail reprogramming.
Press PROG button and keep pressed until desired mode selected.
Programming of one safety transmitter (IN1 input)
3 Safety edge activates the two relays 1 and 2 at the same time ON ON
Programming of two safety transmitters (IN1 and IN2 input)
Mode Configuration of transmitter programming in the receiver. Led R1 Led R2
(with switch SW1: 2 to OFF, the IN2 input is not tested)
ATEST Signal
ATEST signal is used to test the system, and depending on the switch SW1: 2 to turn off the optical safety edge and thus save power.
If SW1: 2 is ON, the response time of the signal is 150ms.
The optical safety edge is always active.
If SW1: 2 is OFF, the response time will be 300ms.
The optical safety edge is turn off to save power. (Only four
transmitters can be programmed into each receiver).
In order to comply with the EN ISO 13849-1:2008 safety standard, it is necessary to connect the autotest signal.