The Radioband system is designed for installation with a safety edge in garage door
installations.
This system allows for wireless safety edge – control panel connection.
To install this system, you must follow the advice included in this manual and take
the requirements of the applicable normative into account.
- R&TTE 1999/5/EC Radio and telecommunication terminal equipment
Directive
Below are some of the requirements of the applicable harmonised standards:
In accordance with the European low voltage directive, you are informed of the
following requirements:
· For permanently connected equipment, an easily accessible connection device
must be incorporated into the cabling.
· This equipment must be installed in a vertical position and firmly fixed to the
structure of the building.
· This equipment may only be handled by a specialized installer, by maintenance
staff or by a properly instructed operator.
· The instructions for use of this equipment must always remain in the possession
of the user.
· Terminals with a maximum section of 3.8mm2 must be used to connect the
cables.
- The frequency of the Radioband system does not interfere in any way with the
868 MHz remote control systems. However a signal centred at 868,9MHz may
cause a delay on the reaction of the system.
- Always connect the door structure and metal parts to an earthing connection.
- Do not share the power and signal supply.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 3
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
The Radioband system is in line with the Machines Directive under EN 954-1,
Category 2.
JCM TECHNOLOGIES, S.A. declares herewith that the product
RADIOBAND/TA, RADIOBAND/TBX, RADIOBAND/RU, RADIOBAND/RC-RCS,
complies with the requirements of the 1999/5/ CEE R&TTE Directive,
89/336/EEC Directive on electromagnetic compatibility and 73/23/EEC on low
voltage and its subsequent amendment 93/68/EEC, insofar as the product is
used correctly.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
To comply with FCC rules, adjustment or modifications of this receiver and/or
transmitter are prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Any other
changes made, not expressly approved by JCM Technologies, S A could void
the user’s authority to operate the equipment.
CE DECLARATION OF CONFORMITY
See website www.motion-line.com
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 4
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
2. THE SYSTEM
2.1 RADIOBAND/TA, RADIOBAND/TBX
RADIOBAND/TA
Safety edge connection
Programming button
RADIOBAND/TBX
RADIOBAND/TA RADIOBAND/TBX
Operating frequency 868.90MHz
Power supply 3V DC (2 x 1.5V LR03 AAA) 3V DC (2 x 1.5V LR6 AA)
Op. consumption 12mA
Radiated power < 25mW
Op. temperature -20ºC - +55ºC
Seal IP65
Dimensions 85 x 53 x 36mm 160 x 53 x 20mm
Range (guaranteed) 10m
Battery life (estimated) 2 years
Minimum time between two
RADIOBAND/TA or RADIOBAND/TBX
activations (for complying with the
R&TTE Directive)
7 min
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 5
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
INSTALLATION AND CONNECTIONS
Fix the back of the box to the door. Install the transmitter following the technical
manual and avoid placing metallic surfaces between the receiver and the
transmitter. Pass the cables through the bottom of the transmitter. Connect a
resistive 8K2 safety band directly to terminal B1 and ensure that the safety edge
keeps totally waterproof. Fix the front of the transmitter to the back with the screws
supplied for the purpose.
N.B.: If a non-resistive element (with a contact normally closed) needs to be
connected, the jumper JP4 must be bridged. This application does not comply with
safety standard EN 12453 for the use of motorised garage doors, since the
connection of the resistive element to the RADIOBAND/TA and RADIOBAND/TBX is
not checked.
OPERATION
The receiver checks that all the programmed bands are working properly. If a band
is activated or if there is an error in its operation, the receiver activates the output
relay.
PROGRAMMING RADIOBAND/TA, RADIOBAND/TBX
If the receiver is in programming (see MANUAL PROGRAMMING on page 10 or
16), press the transmitter button to programme it into the receiver.
If the battery of a transmitter programmed into the receiver becomes low, it will
give out 4 short signals every 20 seconds. If there is more than one transmitter
programmed, the safety band must be activated to check whether the receiver then
makes these 4 short signals. If this is the case, the transmitter connected to the
activated safety band will be the one with the low battery. Change it.
CHANGING THE BATTERY
Remove the box cover. The batteries are positioned on the back of the cover.
Replace the two used batteries with new ones, taking into account the polarity
indicated by the connector. Check that the new batteries support the same
temperature range as those they are replacing.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 6
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
INSTALLATION ADVICE
I
nstall the equipment so that
the cable outlet is at the bottom
In installations likely to have range problems
between the transmitter and the receiver,
the antenna must stand vertically from
the hole in the gland
Do not fit the equipment
at ground level
Do not place metal surfaces between
the transmitter and the receiver
The transmitter and receiver anten a
must be parallel to each other for
optimum signal reception
n
* Once the system has been installed, check it works correctly by enabling the
safety edge on the ends of the door.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 7
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
2.2 RADIOBAND/RU
Frequency 868.90MHz
Memory 6 RADIOBAND/TA and/or RADIOBAND/TBX (3 on
relay 1, 3 on relay 2)
Number of relays 2 relays
Power supply 12/24V AC/DC
Power supply range 9-35V DC
8-28V AC
Relay contacts 1A
Consumption: idle/op. 18mA/80mA
Self-test input 2 0/12/24V AC/DC inputs with selectable polarity
Power < 25mW
Op. temperature -20ºC to +85ºC
Seal IP54 (with IP65 cable seals)
Box size 82 x 190 x 40mm
Range (guaranteed) 10 metres
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 8
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
INSTALLATION AND CONNECTIONS
Fix the back of the box to the wall, using the wall plugs and screws supplied.
Install the receiver, close to the door and avoid metal surfaces between the
receiver and the transmitter. Pass the cables through the bottom of the receiver.
Connect the power cables to the terminals of the printed circuit, following the
indications of the connections diagram. Store RADIOBAND/TA and/or
RADIOBAND/TBX. Fix the front of the receiver to the back with the screws supplied
for the purpose.
1- Power supply 12/24V AC/DC: (+)
2- Power supply 12/24V AC/DC (-)
3,4- R1: Connection to the safety band input of the control panel
(resistive contact 8.2kΩ) with jumper in position BS1 (see
CONNECTIONS Figure 1). Or to the control panel safety contact input
(NC) with jumper in position CS1 (see CONNECTION Figure 2).
5,6- R2: Connection to a second safety band input of the control panel
(resistive contact 8.2kΩ) with jumper in position BS2. Or to the control
panel safety contact input (NC) with jumper in position CS2.
7- AUTOTEST: Common connection safety self-test (-). See
CONNECTIONS Figure 3 and table POLARIZED SELF-TEST.
8- AUTOTEST: Self-test connection for R1. See CONNECTIONS Figure
3 and table POLARIZED AUTO-TEST.
9- AUTOTEST: Self-test connection for R2. See CONNECTIONS Figure
3 and table POLARIZED AUTO-TEST.
POLARIZED AUTO-TEST
Check the auto-test output on the control panel, in standby, to see whether the
voltage is 0V (inverted test input) or 12/24V AC/DC (positive polarity). The autotest signal of the panel must remain at its maximum for 2 seconds.
Autotest
output in
standby
Connection to a
equipment with
autotest
Connection to a
equipment without
autotest**
0V 12/24V Positive OFF Connecte
12/24V 0V inverted ON Connecte
--- --- --- OFF No
* N.B.: Only connect the auto-test output to be used.
** Where the auto-test is not used, the system is not checked at the start of the operation,
which means that security normative EN 12453 regarding the use of motorised garage
doors is, in some cases, not complied with.
Autotest
output
activated
Polarity
type
Jumper
ATEST POL
ATEST1 ATEST2
Connecte
d*
d*
connected
d*
Connecte
d*
No
connected
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 9
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Loading...
+ 20 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.