JCM Radioband Installation Manual

Page 1
RADIOBAND SYSTEM INSTALLATION MANUAL
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 1
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 2
CONTENTS
CONTENTS ...................................................................................................................... 2
1. INTRODUCTION ......................................................................................................... 3
2. THE SYSTEM .............................................................................................................. 5
2.3 RADIOBAND/RC-RCS ........................................................................................ 15
3. AUTO-TEST FUNCTION........................................................................................... 19
3.1 AUTO-TEST DESCRIPTION............................................................................... 19
3.2 RADIOBAND/RCS CONNECTIONS................................................................... 20
4. RADIOBAND SYSTEM INSTALLATION RECOMMENDATIONS........................... 21
4.1 Installation on roller door with control panel and RADIOBAND/RU. ............ 21
4.2 Installation on two-leafed swing door with control panel and
RADIOBAND/RC-RCS. .............................................................................................. 21
4.3 Installation on horizontal sectional door with control panel and
RADIOBAND/RU. ...................................................................................................... 22
4.4. Installation on angled sectional door with control panel and
RADIOBAND/RU. ...................................................................................................... 22
4.5 Installation on stackable sectional door with control panel and
RADIOBAND/RU. ...................................................................................................... 23
4.6 Installation on one-leafed residential folding door with control panel with
RADIOBAND/RC-RCS card connector..................................................................... 23
4.7 Installation on one-leafed folding door for communities with control panel
and RADIOBAND/RU................................................................................................ 24
4.8 Installation on one-leafed sliding door with control panel and
RADIOBAND/RU. ...................................................................................................... 24
4.9 Installation on sliding door with control panel and RADIOBAND/RC-RCS
card connector........................................................................................................... 25
4.10 Installation on guillotine door with control panel and RADIOBAND/RU.... 25
5. JCM CONTROL PANEL DIAGRAM FOR CONNECTION TO THE RADIOBAND
SYSTEM.......................................................................................................................... 26
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 2
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 3
1. INTRODUCTION
1.1 System description
The Radioband system is designed for installation with a safety edge in garage door installations. This system allows for wireless safety edge – control panel connection.
To install this system, you must follow the advice included in this manual and take the requirements of the applicable normative into account.
1.2 Normative requirements
The directives applicable to this system are:
- 98/37/EC Machines Directive
- 73/23/EEC Low Voltage Directive
- 2004/108/EC Electromagnetic Compatibility Directive
- R&TTE 1999/5/EC Radio and telecommunication terminal equipment
Directive
Below are some of the requirements of the applicable harmonised standards:
In accordance with the European low voltage directive, you are informed of the following requirements:
· For permanently connected equipment, an easily accessible connection device must be incorporated into the cabling.
· This equipment must be installed in a vertical position and firmly fixed to the structure of the building.
· This equipment may only be handled by a specialized installer, by maintenance staff or by a properly instructed operator.
· The instructions for use of this equipment must always remain in the possession of the user.
· Terminals with a maximum section of 3.8mm2 must be used to connect the cables.
- The frequency of the Radioband system does not interfere in any way with the 868 MHz remote control systems. However a signal centred at 868,9MHz may cause a delay on the reaction of the system.
- Always connect the door structure and metal parts to an earthing connection.
- Do not share the power and signal supply.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 3
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 4
The Radioband system is in line with the Machines Directive under EN 954-1, Category 2.
JCM TECHNOLOGIES, S.A. declares herewith that the product RADIOBAND/TA, RADIOBAND/TBX, RADIOBAND/RU, RADIOBAND/RC-RCS, complies with the requirements of the 1999/5/ CEE R&TTE Directive, 89/336/EEC Directive on electromagnetic compatibility and 73/23/EEC on low voltage and its subsequent amendment 93/68/EEC, insofar as the product is used correctly.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
To comply with FCC rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Any other changes made, not expressly approved by JCM Technologies, S A could void the user’s authority to operate the equipment.
CE DECLARATION OF CONFORMITY
See website www.motion-line.com
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 4
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 5
2. THE SYSTEM
2.1 RADIOBAND/TA, RADIOBAND/TBX
RADIOBAND/TA
Safety edge connection
Programming button
RADIOBAND/TBX
RADIOBAND/TA RADIOBAND/TBX Operating frequency 868.90MHz Power supply 3V DC (2 x 1.5V LR03 AAA) 3V DC (2 x 1.5V LR6 AA) Op. consumption 12mA Radiated power < 25mW Op. temperature -20ºC - +55ºC Seal IP65 Dimensions 85 x 53 x 36mm 160 x 53 x 20mm Range (guaranteed) 10m Battery life (estimated) 2 years Minimum time between two RADIOBAND/TA or RADIOBAND/TBX activations (for complying with the R&TTE Directive)
7 min
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 5
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 6
INSTALLATION AND CONNECTIONS
Fix the back of the box to the door. Install the transmitter following the technical manual and avoid placing metallic surfaces between the receiver and the transmitter. Pass the cables through the bottom of the transmitter. Connect a resistive 8K2 safety band directly to terminal B1 and ensure that the safety edge keeps totally waterproof. Fix the front of the transmitter to the back with the screws supplied for the purpose.
N.B.: If a non-resistive element (with a contact normally closed) needs to be connected, the jumper JP4 must be bridged. This application does not comply with safety standard EN 12453 for the use of motorised garage doors, since the connection of the resistive element to the RADIOBAND/TA and RADIOBAND/TBX is not checked.
OPERATION
The receiver checks that all the programmed bands are working properly. If a band is activated or if there is an error in its operation, the receiver activates the output relay.
PROGRAMMING RADIOBAND/TA, RADIOBAND/TBX
If the receiver is in programming (see MANUAL PROGRAMMING on page 10 or
16), press the transmitter button to programme it into the receiver.
TRANSMITTER BATTERY LOW INDICATOR (RADIOBAND/TA, RADIOBAND/TBX)
If the battery of a transmitter programmed into the receiver becomes low, it will give out 4 short signals every 20 seconds. If there is more than one transmitter programmed, the safety band must be activated to check whether the receiver then makes these 4 short signals. If this is the case, the transmitter connected to the activated safety band will be the one with the low battery. Change it.
CHANGING THE BATTERY
Remove the box cover. The batteries are positioned on the back of the cover. Replace the two used batteries with new ones, taking into account the polarity indicated by the connector. Check that the new batteries support the same
temperature range as those they are replacing.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 6
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 7
INSTALLATION ADVICE
I
nstall the equipment so that
the cable outlet is at the bottom
In installations likely to have range problems between the transmitter and the receiver, the antenna must stand vertically from the hole in the gland
Do not fit the equipment at ground level
Do not place metal surfaces between the transmitter and the receiver
The transmitter and receiver anten a must be parallel to each other for optimum signal reception
n
* Once the system has been installed, check it works correctly by enabling the safety edge on the ends of the door.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 7
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 8
2.2 RADIOBAND/RU
Frequency 868.90MHz Memory 6 RADIOBAND/TA and/or RADIOBAND/TBX (3 on
relay 1, 3 on relay 2) Number of relays 2 relays Power supply 12/24V AC/DC Power supply range 9-35V DC
8-28V AC Relay contacts 1A Consumption: idle/op. 18mA/80mA Self-test input 2 0/12/24V AC/DC inputs with selectable polarity Power < 25mW Op. temperature -20ºC to +85ºC Seal IP54 (with IP65 cable seals) Box size 82 x 190 x 40mm Range (guaranteed) 10 metres
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 8
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 9
INSTALLATION AND CONNECTIONS
Fix the back of the box to the wall, using the wall plugs and screws supplied.
Install the receiver, close to the door and avoid metal surfaces between the receiver and the transmitter. Pass the cables through the bottom of the receiver.
Connect the power cables to the terminals of the printed circuit, following the indications of the connections diagram. Store RADIOBAND/TA and/or RADIOBAND/TBX. Fix the front of the receiver to the back with the screws supplied for the purpose.
1- Power supply 12/24V AC/DC: (+) 2- Power supply 12/24V AC/DC (-)
3,4- R1: Connection to the safety band input of the control panel (resistive contact 8.2k) with jumper in position BS1 (see CONNECTIONS Figure 1). Or to the control panel safety contact input (NC) with jumper in position CS1 (see CONNECTION Figure 2). 5,6- R2: Connection to a second safety band input of the control panel (resistive contact 8.2k) with jumper in position BS2. Or to the control panel safety contact input (NC) with jumper in position CS2.
7- AUTOTEST: Common connection safety self-test (-). See
CONNECTIONS Figure 3 and table POLARIZED SELF-TEST.
8- AUTOTEST: Self-test connection for R1. See CONNECTIONS Figure
3 and table POLARIZED AUTO-TEST.
9- AUTOTEST: Self-test connection for R2. See CONNECTIONS Figure
3 and table POLARIZED AUTO-TEST.
POLARIZED AUTO-TEST
Check the auto-test output on the control panel, in standby, to see whether the voltage is 0V (inverted test input) or 12/24V AC/DC (positive polarity). The auto­test signal of the panel must remain at its maximum for 2 seconds.
Autotest
output in
standby Connection to a equipment with autotest
Connection to a equipment without autotest**
0V 12/24V Positive OFF Connecte
12/24V 0V inverted ON Connecte
--- --- --- OFF No
* N.B.: Only connect the auto-test output to be used.
** Where the auto-test is not used, the system is not checked at the start of the operation, which means that security normative EN 12453 regarding the use of motorised garage doors is, in some cases, not complied with.
Autotest output activated
Polarity type
Jumper ATEST POL
ATEST1 ATEST2
Connecte
d*
d*
connected
d*
Connecte d* No connected
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 9
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 10
LIGHT INDICATORS
RADIOBAND/R U-RC-RCS Relay 1 LED Normally off.
Relay 2 LED Normally off.
In operation In programming
On. Indicates the channel to be Indicates the status of the relay output. If R1 is not connected, on.
Indicates the status of the relay output. If R2 is not connected, on.
programmed.
On. Indicates the channel to be
programmed.
OPERATION
The receiver checks that all the programmed bands are working properly. If a band is activated or if there is an error in its operation, the receiver activates the output relay.
MANUAL PROGRAMMING
RADIOBAND/RU makes it possible to store 6 RADIOBAND/TAs and/or RADIOBAND/TBXs (3 on Relay 1 and 3 on Relay 2).
Press the receiver programming PROG button for 1s; a sound signal will be heard. The receiver will go into programming the first relay. If the programming button is kept pressed, the receiver will go into programming the second relay, moving cyclically from one really to another. Once the programming relay has been chosen for the transmitter you want to start using, send the programming code by pressing the transmitter. Every time a transmitter is programmed, the receiver will emit a sound signal for 0.5s. If 10 seconds pass without programming, the receiver will go out of programming mode, emitting two 1s sound signals. If, when programming a transmitter, the receiver's memory is full, it will emit 7 sound signals lasting 0.5s and come out of programming.
Note: For a right operation of the system, the transmitter has to be programmed in one receiver only.
RADIOBAND/TA, RADIOBAND/TBX replacement: In case you need to replace a
RADIOBAND/TA or a RADIOBAND/TBX, it is necessary to reset the system (see TOTAL RESET on next page) and reprogram all RADIOBAND/TA and/or RADIOBAND/TBX used in the installation.
SYSTEM CHECK
This function has to be used to check the operation and range of all the devices once the installation has been carried out.
Press the receiver’s CHECK button for at least 1 second to enter check mode. The indicator light will come on and four beeps will be heard. Perform a complete door opening and closing manoeuvre. During the system check a beep will be heard every 1,5 seconds.
CORRECT OPERATION OF THE SYSTEM
If no other acoustic signal is heard on completing the manoeuvre, the system is operating correctly. Either press the CHECK button again or wait 5 minutes and the
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 10
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 11
RADIOBAND/RU will exit checking automatically, indicating with two beeps that the check has been correct. The check indicator light will go out.
DETECTION OF BAND FAILURE
If the communication with a RADIOBAND/TA or a RADIOBAND/TBX fails during checking, or the communication is deficient (for instance, too many communication retries or poor coverage), the RADIOBAND/RU emits three consecutive beeps, indicating that an error has occurred. Halt the door manoeuvre and press the safety bands installed to detect what has failed.
- If a single beep is heard on pressing a band, this means that the band is
correct.
- If three consecutive beeps are heard on pressing the band, this means that
the band has failed.
In this event, it is recommended changing the orientation of the transmitting-receiving aerials or installing an AED-868 or FLAT-868 outdoor aerial to ensure the desired range.
On exiting check mode, seven consecutive beeps will be heard and the indicator light will flash continuously. Perform another system check until the result is correct.
Signal coverage
After pressing one of the installed bands, continuous flashes, ranging from 1 to 5, indicate the signal coverage for this band at the time it was pressed.
Number of check LED
Coverage Result of check
flashes
1 Very weak Band failure 2 Weak OK 3 Normal OK 4 Good OK 5 Very good OK
TOTAL RESET
In programming mode, keep the programming PROG button pressed down and make a bridge with the "MR" reset jumper for 3s. The receiver will emit 10 warning sound signals and then more at a faster frequency, indicating that the operation has been carried out. The receiver will stay in programming mode.
If 10 seconds elapse without programming, or if you press the programming button quickly, the receiver will go out of programming mode, emitting two 1s sound signals.
TRANSMITTER BATTERY LOW INDICATOR (RADIOBAND/TA, RADIOBAND/TBX)
If the battery of a transmitter programmed into the receiver becomes low, it will give out 4 short signals every 20 seconds. If there is more than one transmitter programmed, the safety band must be activated to check whether the receiver then makes these 4 short signals. If this is the case, the transmitter connected to the activated safety band will be the one with the low battery. Change it.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 11
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 12
INSTALLATION ADVICE
The transmitter and receiver antenna must be parallel to each other for optimum signal reception
Do not place metal surfaces between the transmitter and the receiver
Do not fit the equipment at ground level
The transmitter and receiver anten a must be parallel to each other for optimum signal reception
n
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 12
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 13
a) Connection to safety edge inlet
b) Connection to security contact inlet
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 13
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 14
c) Auto-test connection with negative polarisation
d) Auto-test connection with positive polarisation
* Once the system has been installed, check it works correctly by enabling the safety edge on the ends of the door.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 14
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 15
2.3 RADIOBAND/RC-RCS
Frequency 868.90MHz Memory 6 RADIOBAND/TA and/or
RADIOBAND/TBX Power supply pluggable Power supply range --­Consumption: idle/op. 18mA Self-test input incorporated Power < 25mW Op. temperature -20ºC to +85ºC Seal IP20 Box size 50x20x17mm Range (guaranteed) 10 metres
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 15
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 16
INSTALLATION AND CONNECTIONS
Connection to a control panel using a connector for safety devices.
LIGHT INDICATORS
RADIOBAND/R U-RC-RCS Relay 1 LED Normally off.
Relay 2 LED Normally off.
In operation In programming
On. Indicates the channel to be Indicates the status of the relay output. If R1 is not connected, on.
Indicates the status of the relay output. If R2 is not connected, on.
programmed.
On. Indicates the channel to be
programmed.
OPERATION
The receiver checks that all the programmed bands are working properly. If a band is activated or if there is an error in its operation, the receiver activates the output relay.
MANUAL PROGRAMMING
RADIOBAND/RC-RCS makes it possible to store 6 RADIOBAND/TAs and/or RADIOBAND/TBXs (3 on Relay 1 and 3 on Relay 2).
Press the receiver programming PROG button for 1s; a sound signal will be heard. The receiver will enter safety band closing programming mode (BSC). If the programming button is kept pressed, the receiver will enter safety band opening programming mode (BSO), moving cyclically from one really to another. Once the programming relay has been chosen for the transmitter you want to start using, send the programming code by pressing the transmitter. Every time a transmitter is programmed, the receiver will emit a sound signal for 0.5s. If 10 seconds pass without programming, the receiver will go out of programming mode, emitting two 1s sound signals. If, when programming a transmitter, the receiver's memory is full, it will emit 7 sound signals lasting 0.5s and come out of programming.
Note: For a right operation of the system, the transmitter has to be programmed in one receiver only.
RADIOBAND/TA, RADIOBAND/TBX replacement: In case you need to replace a
RADIOBAND/TA or a RADIOBAND/TBX, it is necessary to reset the system (see TOTAL RESET on next page) and reprogram all RADIOBAND/TA and/or RADIOBAND/TBX used in the installation.
SYSTEM CHECK
This function has to be used to check the operation and range of all the devices once the installation has been carried out.
Press the receiver’s CHECK button for at least one second to enter check mode. The indicator light will come on and four beeps will be heard. Perform a complete door opening and closing manoeuvre. During the system check a beep will be heard every 1,5 seconds.
CORRECT OPERATION OF THE SYSTEM
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 16
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 17
If no other acoustic signal is heard on completing the manoeuvre, the system is operating correctly. Either press the CHECK button again or wait 5 minutes and the RADIOBAND/RC-RCS will exit checking automatically, indicating with two beeps that the check has been correct. The check indicator light will go out.
DETECTION OF BAND FAILURE
If the communication with a RADIOBAND/TA or a RADIOBAND/TBX fails during checking, or the communication is deficient (for instance, too many communication retries or poor coverage), the RADIOBAND/RC-RCS emits three consecutive beeps, indicating that an error has occurred. Halt the door manoeuvre and press the safety bands installed to detect what has failed.
- If a single beep is heard on pressing a band, this means that the band is
correct.
- If three consecutive beeps are heard on pressing the band, this means that
the band has failed.
In this event, it is recommended changing the orientation of the transmitting-receiving aerials or installing an AED-868 or FLAT-868 outdoor aerial to ensure the desired range.
On exiting check mode, seven consecutive beeps will be heard and the indicator light will flash continuously. Perform another system check until the result is correct.
Signal coverage
After pressing one of the installed bands, continuous flashes, ranging from 1 to 5, indicate the signal coverage for this band at the time it was pressed.
Number of check LED
Coverage Result of check
flashes
1 Very weak Band failure 2 Weak OK 3 Normal OK 4 Good OK 5 Very good OK
TOTAL RESET
In programming mode, keep the programming PROG button pressed down and make a bridge with the "MR" reset jumper for 3s. The receiver will emit 10 warning sound signals and then more at a faster frequency, indicating that the operation has been carried out. The receiver will stay in programming mode.
If 10 seconds elapse without programming, or if you press the programming button quickly, the receiver will go out of programming mode, emitting two 1s sound signals.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 17
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 18
INSTALLATION ADVICE
p
A
8
An AED-868 or FLAT 868 antenna extension to 868 MHz should be installed for greater range. Install the external antenna and its cable at a place where they are protected against damage
n AED-868 or FLAT 868 antenna extension
and vibration, and where no obstacles are
to 868 MHz should be installed for greater range
expected between all RADIOBAND antennas.
Where an antenna extension is not installed, place th e re ce iver card antenna in vertical
868MHz AED-868 or FLAT 86 antenna extension with RG 58 coaxial cable
* Once the system has been installed, check it works correctly by enabling the safety edge on the ends of the door.
osition
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 18
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 19
3. AUTO-TEST FUNCTION
b
b
3.1 AUTO-TEST DESCRIPTION
Before starting operations, the control panel must check that the entire security system is working correctly. The control panel shall not start Auto-test during a pressed safety edge output. To make this check, the panel must act on the auto-test signal.
AUTO-TEST timing correct
Autotest
CS
= indicates the correct autotest of all
ands
AUTO-TEST timing error
Autotest
CS
= indicates the correct autotest of all
ands
While the auto-test is being run to learn of the status of the RADIOBAND/TA or RADIOBAND/TBX, the RADIOBAND/RU questions the status of the different Safety edges inputs. This process ensures the correct working order of the following parts:
Safety edge input
RADIOBAND/TA or RADIOBAND/TBX (1 or several).
RF Channel (if there is any interference)
T
autotest
Autotest OK
T
MAXautotest
Autotest Error
T
T
end
The operation can now be carried out
end
THE OPERATION CANNOT BE STARED AS THE AUTO-TEST HAS NOT BEEN SUCCESSFULLY COMPLETED
RADIOBAND/TA status Auto-test carried out
RADIOBAND/TA status Auto-test carried out
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 19
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 20
RADIOBAND/RU (control and RF)
Switching off the output relay means that the control status and the correct working order of the RADIOBAND/RU output relay has been checked.
Description T
T
min
T
type
max
Tauto-test 10ms 3s
Tend 50 ms
3.2 RADIOBAND/RCS CONNECTIONS
1- Not connected 2- RB_S1: Outlet 1 Radioband activation 3- Mass 4- RB_S2 Outlet 2 Radioband activation 5- 5Vdc power supply 6- RB_AT-1: Inlet 1 Radioband auto-test 7- Not connected 8- RB_AT-2: Inlet 2 Radioband auto-test
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 20
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 21
4. RADIOBAND SYSTEM INSTALLATION RECOMMENDATIONS
4.1 Installation on roller door with control panel and RADIOBAND/RU.
4.2 Installation on two-leafed swing door with control panel and RADIOBAND/RC-RCS.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 21
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 22
4.3 Installation on horizontal sectional door with control panel and RADIOBAND/RU.
4.4. Installation on angled sectional door with control panel and RADIOBAND/RU.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 22
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 23
4.5 Installation on stackable sectional door with control panel and RADIOBAND/RU.
4.6 Installation on one-leafed residential folding door with control panel with RADIOBAND/RC-RCS card connector.
M
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 23
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 24
4.7 Installation on one-leafed folding door for communities with control panel and RADIOBAND/RU.
4.8 Installation on one-leafed sliding door with control panel and RADIOBAND/RU.
M
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 24
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 25
4.9 Installation on sliding door with control panel and RADIOBAND/RC-RCS card connector.
M
4.10 Installation on guillotine door with control panel and RADIOBAND/RU.
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 25
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 26
5. JCM CONTROL PANEL DIAGRAM FOR CONNECTION TO THE RADIOBAND SYSTEM
SINGLE-PHASE PANELS
JCM Control
panels START-EU
RESIDENT+DCS Roller for
ROLLER-
MOTION
BASIC-EU
MAIN-1T-EU Swing, folding
MAIN-2T-EU
Applications Description
Roller for residential and commercial use
residential use
Roller for
residential and
commercial
Sliding for
residential and
community use
and sliding for residential and
community use
Same as
MAIN-1T-EU
use
Semi-automatic operations. 433 or 868 MHz radio card connection. Start button and safety edge connection. Semi-automatic and automatic operations. Built-in 433 MHz receiver. Start/stop button connection, limit switches and security contact on close. Possible to connect the TBAND card. 24Vac outlet Garage light contact “Dead-man” operations (using GO­BUTTON or GO­SWITCH), semi­automatic. Built-in 868 MHz receiver. Start button and safety edge connection. Semi-automatic and automatic operations. 433 or 868 MHz radio card connector. Start, pedestrian and stop button connection. Limit switch, safety edge and security contact connection. Garage light contact 12Vdc outlet Semi-automatic and automatic operations. 433 or 868 MHz radio card connector. Start and stop button connection. Limit switch, safety edge and security contact connection. Traffic light or signal card connector. Garage light contact 24Vac outlet Electro-
lock connection Same as MAIN-1T-EU
for 2 motors
Compatibility with Radioband system RADIOBAND/RU with external power supply
RADIOBAND/RU
RADIOBAND/RU with external power supply
RADIOBAND/RU
RADIOBAND/RU
.
RADIOBAND/RU
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 26
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 27
ADVANCE
STANDARD-1T-
EU
STANDARD-2T-
EU
Swing, folding and sliding for residential and
intensive use.
Swing, folding and sliding for residential and
community use
Same as
STANDARD-
1T-EU
Semi-automatic and automatic operations. Digital programming. Gentle stop. RADIOBAND and other force limiting device (FORCELIMIT and T-HALL) connector. 433 or 868 MHz card connector. Start and stop button connection. Limit switch, Limit switch, safety edge and security contact connection. Electro-lock connection. Traffic light card or signal card connector. Garage light contact 24Vac outlet Auto­test outlet. Semi-automatic and automatic operations. Gentle stop. 433 or 868 MHz radio card connector. Start, pedestrian, stop, open and close button connection. Limit switch, safety edge and security contact connection. Traffic light connector. Garage light and signal contact 24Vac outlet Electro-lock connection. Same as STANDARD­1T-EU for 2 motors
RADIOBAND/RC or RADIOBAND/RU with negative polarisation auto­test function
RADIOBAND/RU
RADIOBAND/RU
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 27
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 28
D.C. PANELS
JCM Control
panels
CONTINUE-EU
NUA
JCM Control
panels
UNIVERSAL-EU Sectional, swing
TRIBASIC-
MOTION
TRIBASIC
D.C. PANELS
Applications
Sectional, swing, folding and sliding for residential and community use
Description
Semi-automatic and automatic operations by limit switch or with Hall sensor. Time control. Electronic motor power limitation without the need for additional devices. 433 or 868 MHz radio card connector. Start and stop button connection. Limit switch, safety edge and security contact connection. Garage light contact. 24Vac outlet
THREE-PHASE PANELS
Applications
and guillotine for community use
Winding and
sectional
for industrial use
Sectional, swing
and sliding for
community use
Description
Semi-automatic and automatic operations. 433 or 868 MHz radio card connector. Open, start and stop button connection. Limit switch and security contact connection. Signal or traffic light card connector. Garage light contact 24Vac outlet Electro-lock connection. Auto-test outlet. “Dead-man” operations Built-in 868 MHz receiver. Open, close, start and stop button connection. Limit switch and security contact connection. Signal or traffic light card connector. Garage light contact 24Vac outlet Semi-automatic and automatic operations. 433 or 868 MHz radio card connector. Start and stop button connection. Limit switch, safety edge and security contact connection. Signal or traffic light card connector. Garage light contact. 24Vac outlet Auto-test outlet.
Compatibility with Radioband system RADIOBAND/RU
Compatibility with Radioband system RADIOBAND/RU with positive polarisation auto­test function
RADIOBAND/RU
RADIOBAND/RU
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 28
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Page 29
TRIBASIC-S/I
TRIBASIC-IND
INDUSTRIAL-
MAN
INDUSTRIAL-EU
TRI-ADVANCE Fast doors Semi-automatic and
Same as
TRIBASIC
Same as
TRIBASIC
Swing for
industrial use
Swing,
sectional,
sliding and
guillotine
for industrial use
Same as TRIBASIC without ON/OFF switch. Auto-test outlet. Same as TRIBASIC but in INDUSTRIAL box. Auto­test outlet. “Dead-man” operations 433 or 868 MHz radio card connector. Open, start and stop button connection. Limit switch connection. Signal or traffic light card connector. Garage light contact 24Vac outlet Electro-lock connection. INDUSTRIAL box with general circuit breaker switch. Semi-automatic and automatic operations. 433 or 868 MHz radio card connector. Open, start and stop button connection. Limit switch and security contact connection. Signal or traffic light card connector. Garage light contact 24Vac outlet Electro-lock connection. INDUSTRIAL box with general circuit breaker switch. Auto-test outlet.
automatic operations. 433 or 868 MHz radio card connector. Open, start and stop button connection. Limit switch, security contact and safety edge connection. Hall sensor connection. Signal or traffic light card / garage light connector. Connector for magnetic sensor card. 24Vac outlet Electro-break outlet. INDUSTRIAL box with general circuit breaker switch. Auto-test outlet.
RADIOBAND/RU
RADIOBAND/RU
RADIOBAND/RU
RADIOBAND/RU with positive polarisation auto­test function
RADIOBAND/RCS or RADIOBAND/RU with negative polarisation auto­test function
RADIOBAND SYSTEM INSTALLATION MANUAL V2.4 / 29
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
Loading...