1257016-GB_v1.2
CONT-R15
GENERAL DESCRIPTION
Control panel for 24 Vdc motors on sectional, swing, folding and sliding doors for residential and
communal use.
Basic features:
- self-programming
- stoppage by consumption
- receiver incorporated (15 codes) / pluggable receiver (433.92 (two-channel)/ 868.35
MHz)
- resistive safety edge inlet (8 k2)
- encoder inlet (sensor hall, ...)
- slow-speed start of operations (programmable)
- slow-speed end of operations (selectable)
- connection to portable programmer
TECHNICAL CHARACTERISTICS
Panel supply 0-12-24Vac
Transformer 0-12-24Vdc / 100VA or 150VA
Receiver 868.35MHz incorporated 15 codes
Optional cards Pluggable receiver card (433,92 (bi-channel) / 868,35 MHz) and
traffic light card (TL-CARD)
Security device output 24V ac / 1A
Operating temperature -20ºC to +85ºC
Airtightness IP54
Equipment category Class II
Base plate size 160x83x27 mm
Box dimensions 225x195x85 mm
BASE PLATE DESCRIPTION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1
1257016-GB_v1.2
CONT-R15
CONNECTION
1 Primary 230V ac Transformer + 230Vac power supply (L)
2 Primary 230V ac Transformer + 230Vac power supply (N)
3 Secondary 0V ac Transformer
4 Secondary 12V ac Transformer
5 Secondary 24V ac Transformer
6 24V ac output
7 24V ac output
8 24V dc motor output
9 24V dc motor output
10 Encoder (+)
11 Encoder (S.H.)
12 Encoder (-)
13 Common buttons
14 Stop (STOP) (NC)
15 Start (START) (NO)
16 Common buttons
17 Open (OPEN) (NO)
18 Close (CLOSE) (NO)
19 Common securities
20 Close security contact (NC) (SEC.CL)
21 Resistive security edge 8K2 (S.EDGE)
22 Common ends of run
23 End of run close (NC) (FC.CL)
24 End of run open (NC) (FC.OP)
INSTALLATION
Any handling of the panel for installation must be carried out with the power supply disconnected.
FITTING THE CASING (only box version)
· Parts: front casing and container box.
· Unscrew the securing points. Insert the cables through the lower holes.
IMPORTANT CONSIDERATIONS FOR START-UP
Where inversions are made, the panel adds time to ensure the door closes.
Any optional cards must be connected to the panel with the power supply disconnected.
2
1257016-GB_v1.2
CONT-R15
OPERATING
Start (START): Contact normally open to open and close. The first press opens, the second press
stops (until the limit switch) and the third closes. If it is pressed while the door is closing, it will
stop and invert the operation.
Stop (STOP): Contact normally closed. This detains the operation on standby for a new order.
Where not used, turn option 1 on the input switch to ON.
Open (OPEN): Contact normally open to open. If it is pressed while the door is closing, it will stop
and open.
Close (CLOSE): Contact normally open to close. If it is pressed while the door is closing, it
and close.
will stop
Security contact (SEC.CL): Contact normally closed, photocell or magnetic detector type. This
acts on closing, causing stoppage and inversion. Where not used, turn option 2 on the input
switch to ON.
Security edges (S.EDGE): Resistive contact for resistive security edge. This acts on closing, causing
stoppage and inversion. Where not used, turn option 3 on the input switch to ON.
Where option 6 of the options switch is turned to ON, the band is inhibited during the last 4 cm of
door closure.
Ends of run (FC.CL / FC. OP): contacts normally closed to mechanically indicate the open and
closed end of run. Where not used, turn option 4 or 5 on the input switch to ON.
24Vac outlet enables any unit to be powered at a voltage of 24Vac with a maximum consumption
of 1A.
Encoder inlet (+, S.H., -): Allows for an NPN-type encoder (or sensor hall) to be connected at 5Vdc,
necessary for the operation by pulses.
Reference search function: If the panel loses power halfway through the operation, on receiving
power it goes into reference search mode, in such a way that the door will move until a mechanical
stop or the end of the run is reached, with preference given to the opening reference, if it exists.
Reference search is indicated by the corresponding flashing of the SAFETY light (see table).
The Aut ref Search parameter (configurable by means of programmer) is selected if the user requires
this automatic search or wishes to wait for the START button to be pressed for the reference search.
N.B.: The panel may lose the reference if the power is disconnected halfway through the operation.
Door operation control function with external clock: By connecting an external clock or timer
(normally open) between the common push button terminal (16) and the bridged Open and Close
terminals (17 and 18), it is possible to temporize the opening and closing of the door.
Back Jump Function: With this function, the panel causes a small delay in the door at the end of
the operation to prevent voltage in the mechanism or to avoid pressure on the safety edge, where
applicable. The time of the delay can be defined using advanced programmer parameters.
OPTION SWITCH
Option No. Upper position – ON Lower position - OFF
1 (AUTO PROG) Self-programming Manual programming (default option)
2 (AUTO CLOSE.) Automatic closure Does not close automatically (default option)
3- NON STOP ON
OPENING
4 (SLOW) Allows for slow speed (default option) Does not allow for slow speed
5 (COURTESY L /
ELECT)
6 (INH.SEC.EDGE Inhibits the security edge for the last 4 cm of Does not inhibit the security edge (default
Does not allow for radio reverse on opening Allows for radio reverse on opening (default
Garage light comes on (default option). Garage
light contact time = Operating time + 30
seconds.
option)
Works like an electro-lock (1.5 seconds before
opening)
3