JCC Lighting Products JC1019/WHBLK JC1019WH Instructions

V50™ Pro Anti-glare
Wire preparation
1.0 -1.5
EE
Installation instructions for V50™ Pro Fire-rated Downlight
Warnings and cautions
To avoid electric shock, serious injury or property damage, isolate power before installing, removing or servicing the product
It is recommended that luminaires are installed by a qualied electrician and the installation complies with the local current wiring regulations.
Any broken or damaged parts should be replaced as soon as possible. JCC will not accept responsibility for claims arising from sub-standard installations.
It is recommended that the ambient room temperature should not exceed 25°C.
INSTALLATION
a company
These products are designed for connection to a mains supply of 230-240V~ 50/60Hz
This Fire-rated downlight can be loosely covered with mineral wool insulation
Do not carry out insulation tests with the product connected to the circuit
For dimming guidelines please go to: jcc.co.uk/dimming
Specication :
Colour Temperature: (WW)3000K* / (CW)4000K (Switchable)
Ra: 80
Wattage Lumens LpcW IP
7.5W 600*/650lm 80*/87 IP65
Maximum number of ttings on a circuit is not to exceed 20
Read the instructions and ensure that you have all of the tools and accessories required to complete the installation correctly.
Isolate power supply before starting the installation.
Installation Procedure
1. Cut the mounting hole in the ceiling; if you are unfamiliar with this process
JCC recommends that a sample hole is cut in a section of spare material Please note that the Standard & Tilt versions have different diameter mounting holes (Fig. 1).
Fig.1: Suitable for cut-out
(front only)
Ø70-76mm
ENGLISH
Fig. 3: Driver Input Terminals
Live/Earth/Neutral/Neutral/Earth/Live
3. At this stage it would be advisable to ensure that the correct CCT
value has been selected for the application: the options are either Warm White or Cool White, and these can be altered by means of a small slider switch. On the Standard version the switch is located behind the detachable ‘twist-off’ bezel (Fig. 4A) Once you have select your
preferred colour temperature, ret the Bezel.
Fig. 4a: CCT Switch
230 - 240V 50/60Hz / Class II
Note: Earth provision only
2. Once the mounting hole has been cut to the correct diameter the mains input power feed (Fig. 2) can be wired to the driver. This luminaire is Class II, but are equipped with Earth provision, should it be required (Fig. 3).
Fig. 2: Mains input
To access the terminals inside the driver housing, open the top and bottom hinged covers as as shown on the right.
You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipment to an appropriate waste disposal centre. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service.
RoHS
Compliant
IP65(front only)
4. Once the electrical connection has been made, and the colour
temperature selected, the luminaire can now be inserted into the cut-out. Carefully push both spring clips up against the side of the luminaire and hold in place. Insert the V50™ Pro downlight into the cut-out and release the clips to securely locate the product in place.
5. When the luminaire is correctly installed the power may be switched on and the product can be tested.
75mm
Insulation
Insulation
Ceiling
75 mm min
jcc.co.uk
75 mm min
400/600mm joist centres
75 mm min
Joist
This area free from insulation
V4_August_2022_RS
Part B Fire Safety
Important warranty information
This product is supported by a 2-year standard warranty which will extend to 3 years for commercial applications and 5 years fo applications if registered within the first year of purchase. Please register at jcc.co.uk/warranty (Terms and conditions appl
The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chas Product Code/Date Code.
Technical Support: +44(0)1243 838986 Customer Services: +44(0)1243 838999
BS EN ISO9001 - 2015 - Registered Firm Certificate No. GB 1552
The purpose of Part B is to ensure building structures provide adequate protection to personnel to allow the safe evacuation of a building structure/complex.
The regulation has been a legal requirement since 1987. All Fire-rated ttings are tested for 30, 60 & 90 minute ceilings (selected I-Joist ceiling construction
30 & 60 minute compliant).
Part C Resistance to Contaminants and Moisture
The amount of moisture that can enter a cold roof void must be controlled; thus anything which punctures the seal between the cold roof area and dwelling
area must be considered. Light ttings are a good example of intrusions into the roof area that can facilitate the passage of moisture. Fire-rated downlights have been designed with special seals to inhibit the ow of air & moisture through the tting as required by Part C of the building regulations.
Part E Resistance to Sound
There is a general increase in the levels of background noise in a domestic environment. The Government has changed to the building regulations to ensure that reasonable noise attenuation can be expected between partition walls and ceilings not only between separate dwellings but also within individual residential area. The special gaskets incorporated into the Fire-rated design ensure that the criteria is met.
Part L Conservation of Fuel and Power
The 2022 revision to Part L has focused on lighting installations regarding energy conservation. The requirement is that downlights installed in a new or
existing domestic dwelling need to be energy efcient and have an minimum efciency of 75 Lumens per circuit Watt.
Prole & Dimensions
28.8
59.1
62.7
380
85 40
All dimensions in millimetres