Architectural Exterior Range
Installation instructions for exterior Lantern range
Warnings & Cautions
• To avoid electric shock, serious injury or property damage, isolate
power before installing, removing or servicing the product.
• It is recommended that luminaires are installed by a qualied
electrician to ensure the installation complies with the local current
wiring regulations.
• To maintain the IP rating the correct LED lamp must be installed.
Suitable for GLS shaped LED lamps only.
a
• These products are designed for connection to a 200-240V~
50/60Hz supply.
• This luminaire is suitable for indoor and outdoor use.
• Any broken or damaged parts should be replaced as soon as possible.
JCC will not accept responsibility for claims arising from sub-standard
installations; which will void the warranty.
Specications
Product code Wattage
JC17007
JC17008* 13.6W 830 61
JC17036
JC17037
JC17038
15W ES E27 LED
max
15W ES E27 LED
max
15W ES E27 LED
max
15W ES E27 LED
max
*Colour temp: 3000K *Ra: 86
200-240V~ 50/60Hz / Class I
Figure 1. Mains input
Live = Brown
Neutral = Blue
Lumens LpcW
n/a n/a
n/a n/a
n/a n/a
n/a n/a
Live = Brown
Yellow/green
Neutral = Blue
INSTALLATION
ENGLISH
Available nishes: Black or White
Installation procedure
1. Remove body from base/back plate and use as a template for xing
ensuring correct orientation (arrow up).
2. Feed cable through grommet, ensuring water tight prior to xing in
desired location.
3. Terminate electrical connections as shown in Fig 1.
4. Fit suitable LED lamp as required (max 15W LED).
5. Ret body and secure with xings.
6. Turn on supply and test for operation.
N.B. To t lamp remove top cover using suction cup for glass
(bollard only).
RoHS
Compliant
IP54
jcc.co.uk
V9_Sept_2022_RS

Architectural Exterior Range
a
Dip switch settings
1. PIR override
JC17036- PIR operation
ENGLISH
PIR overide gives you the option to allow the sensor to operate in any light level (daylight) or
below 10lux(twilight)
To override the sensor select “on” and this will operate regardless of light levels.
To operate in Auto mode which will operate in low light levels 10 lux or below(twilight) select
the off postion.
2. PIR sensitivity
PIR sensitivity will alow you to select the range or distance of detection.
To select High sensitivity( up to 8 metres) ensure the PIR sensitivity dip switch is in the “off”
position.
To select Low sensitivity (up to 3 metres) push dip switch to “on” position
3. PIR Time delay
Time delay options are :
5 seconds(5”), 30 seconds(30”), 1 minute(1’), 3 minutes(3’), 5 minutes(5’), 8 minutes(8’)
Push dip switch to “on” for required time delay. If all are in the “off” position the default time
delay is 5 seconds(5”)