JCC JC14003, JC14002, JC14001 User Manual

Technical Support: +44(0)1243 838986 Customer Services: +44(0)1243 838999
BS EN ISO9001 - 2015 - Registered Firm Certificate No. GB 1552
+(L) +(L)
Remove end cap before fitting power supply
Important warranty information
This product is supported by a 2-year standard warranty. (See website for terms and conditions).
Installation instructions for mainline track
Warnings & Cautions
a company
To avoid electric shock, serious injury or property damage, isolate power before installing, removing or servicing the product.
It is recommended that this product is installed by an electrician or a
competent person with sufcient experience to install this product.
To be installed in accordance with the local current wiring regulations and standards.
This product is suitable for indoor use only.
It is recommended that the ambient room temperature should not
exceed 25°C.
INSTALLATION
Specication :
Mains supply 240V 50/60Hz / Class I
Available nishes: black or white
Read the instructions and ensure that you have all of the tools and accessories required to complete the installation correctly. Isolate power supply before starting the installation.
You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipment to an appropriate waste disposal centre. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service.
Any broken or damaged parts should be replaced as soon as possible. JCC will not accept responsibility for claims arising from sub-standard installations; which will void the warranty.
These products are designed for connection to a 240V~ 50/60Hz supply.
It may be necessary to upgrade your MCBs to allow for increased inrush current.
Do not carry out insulation tests with the product connected to the circuit.
ENGLISH
Installation
Please Note
All pre - cut mains track, is supplied complete with ready inserted dead end insulation caps. The insulation cap (as shown) is removed to allow the insertion of the Live End Feed: JC14009 Power Feed at Track End c/w Conduit Entry(ordered separately) JC14013 Power Feed at Track End(ordered separately) Sizes shown in the JCC catalogue are by way of a guide only, please make note of drawing details shown in the table below:
Cutting Track
When reducing the length of track i.e. cutting down. It is recommended that a piece of masking tape be wrapped around the intended cutting area, this will ensure the
powder coated or plated nish does not lift and chip. It is recommended for a good electrical connection the installer should always mark out and cut track accurately
using an engineers square prior to cutting. Ensure the copper conductors are pushed fully to one end of the track prior to cutting, the conductors should be towards the live end termination point.
Hint
Our recommendation would be to remove a section of material from the end of the track that is opposite to that of the live feed. This would ensure a perfect connection and trouble free operation. Always ensure that the locking screw is tightened.
Part Codes Actual Track size less
End Caps(Dim ‘A’)
JC14001 510mm 594mm 630mm
JC14002 1120mm 1204mm 2440mm
JC14003 2340mm 2424mm 2460mm
O/All Assembled Track Length with JC14013 (Dim ‘B’)
O/All Assembled Track Length with JC14009(Dim ‘B’)
Features:
● UK approved 16 Amp mains track.
● Manufactured in accordance to EN60 570.
● Fully Earthed system.
● Comprehensive range of accessories.
● Easy to install.
JC14013
Power Feed