Commercial Wall Bulkhead
Installation instructions for Wall Pack
Warnings & Cautions
a
It is recommended that luminaires are installed by a qualied electrician to ensure the installation complies with the local current wiring regulations
prone to ooding. Ensure that the mounting surface is both at
and stable
These products are designed for connection to a 220-240V~ 50/60Hz supply.
INSTALLATION
Specications Colour temp: 4000K Ra: 80
Total circuit
wattage
20W 1750 87
30W 2600 87
Beam angle: 110°
220-240V~ 50/60Hz Class I
Figure 1. Mains input
Standard versions Emergency version
Lumens LpcW
Any broken or damaged parts should be replaced as soon as possible. JCC will not accept responsibility for claims arising from sub-standard installations
It may be necessary to upgrade your MCBs to allow for increased inrush current.
This luminaire is suitable for outdoor use.
ENGLISH
Read instructions and check that you have all of the tools and accessories required to complete the installation correctly. Isolate power supply before starting the installation.
Installation procedure
1. Remove cover by loosening all screws.
2. Drill mounting holes and insert suitable wall plugs.
3. Prepare the mains input cable for termination. Note that this product
is class I and as such must be tted with an earth connection.
4. Terminate input wiring to the tting as per Fig. 1.
5. For emergency version, connect the battery connector lead to the
invertor.
6. Secure in desired location.
N
L
N
SL
PL
SL= Switched live PL= Permanent live
Terminal block must comply to EN 60998-2-1 or EN 60998-2-2
Operating lux level for Photocell versions
Dusk (on) Dawn (off)
20W 10-20lux 30-80lux
30W 10-20lux 30-60lux
General Maintenance Requirements
This product has no user servicable parts. JCC Lighting Products would recommend that the following maintenance is performed in order to prolong the life of this
product: Clean with a damp cloth and dry with a lint free cloth or kitchen towel.
Do not use abrasive cleaners.
7. Ret the cover and ensure the seal is correctly seated to maintain
IP65 rating.
8. Turn on power supply and test for correct operation.
Note - optimum mounting height - 3m
It is the responsibility of the installer to maintain the IP rating when mounting and connecting the mains.
Emergency version
Familiarise yourself with the enclosed emergency ttings test record sheet
and ensure it is completed as required and left with the end user.
RoHS
Compliant
IP65
jcc.co.uk V5_Sept_2022_RS
Important warranty information
This product is supported by a 2-year standard warranty which will extend to 5-years if registered within the first year of pu (2 year on batteries). Please register at jcc.co.uk/warranty (Terms and conditions apply).
The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chas Product Code/Date Code.
Prole & Dimensions
C
A
Technical Support: +44(0)1243 838986 Customer Services: +44(0)1243 838999
BS EN ISO9001 - 2015 - Registered Firm Certificate No. GB 1552
B
D
A B C D
20W 206 188 222 85
30W 288 264 308 126
All dimensions in millimetres
You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical
equipment to an appropriate waste disposal centre. The packaging material is recyclable. Dispose of the packaging in an
environmentally friendly manner and make it available for the recyclable material collection service.
JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, PO20 2FT
rchase.
sis:
Loading...
+ 1 hidden pages