ToughoodAsymmetric
Installation of LED Floodlights
WARNNIGS AND CAUTIONS
a
• It is recommended that luminaires are installed by a qualied
electrician to ensure the installation complies with the local current
wiring regulations.
• Any broken or damaged parts should be replaced as soon as
posible. JCC will not accept responsibility for claims arising from
sub-standard installations.
• Do not install in areas that are exposed to continual running water or
prone to ooding. Ensure that the mounting surface is both at
and stable.
INSTALLATION
Specications Colour temp: 4000K Ra: 70
Total circuit
wattage
80W 9200 115
100W 11400 114
150W 17000 113
200W 24000 120
Finish: Grey
Lumens LpcW
• These products are designed for connection to a 220-240V~
50/60Hz supply.
• It may be necessary to upgrade your MCBs to allow for increased
inrush current.
• Terminal block not included. Installation may require advice from a
qualied person.
• To avoid electric shock, serious injury or property damage, isolate power
before installing, removing or servicing the product.
• Do not carry out insulation tests with the product connected to
the circuit.
ENGLISH
• Read instructions and check that you have all of the tools and
accessories required to complete the installation correctly. Isolate
power supply before starting the installation.
Installation procedure
1. Prepare the mains input cable for termination. Note that this
product is class I and as such must be tted with an
earth connection.
2. Drill mounting holes and insert suitable wall plugs.
3. Rotate tting to access screw mounting points on the bracket and
secure using suitable xings.
220-240V~50/60Hz / Class I
Figure 1. Mains input
brown
Earth
yellow/green
Neutral (-)
blue
Wiring colours are for reference only
Terminal block must comply to EN 60998-2-1 or EN 60998-2-2
Terminal block specication:
Number of Ways 3
Mounting Type Through Hole
Pitch 8mm
Current Rating 24A
Termination Method Screw Down
Wire Size 2.5 mm²
Material Nylon
Voltage Rating 380 V
Maximum Operating Temp +125°C
Contact Material Brass
Contact Plating Nickel
General Maintenance Requirements
JCC recommends that all exterior products, especially those with stainless steel
components are cleaned with warm water and dried with a chamois leather or
absorbent dry cloth. Weathering, environmental pollution and bird droppings
should be cleaned off with a non-abrasive cleaner suitable for the material type.
To preserve the nish of the product, clean every two to three months. After
installation is complete, then bi-annually, grease or lubricate removable xings,
to help ensure maintenance is trouble free.
4. Terminate input wiring to the tting as per Fig. 1 to the left using a
suitable IP rated connector.
5. Check seals, gaskets and the cable gland integrity before testing
the luminaire.
6. Turn on power supply and test for correct operation.
RoHS
Compliant
IP65
jcc.co.uk
V5_Oct_2022_RS

Technical Support: +44(0)1243 838986 Customer Services: +44(0)1243 838999
BS EN ISO9001 - 2015 - Registered Firm Certificate No. GB 1552
Important warranty information
This product is supported by a 2-year standard warranty which will extend to 5-years if registered within the first year of pu
Please register at jcc.co.uk/warranty (Terms and conditions apply).
The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chas
Product Code/Date Code.
Prole&Dimensions
Ø22
70
R6
250
90
All dimensions in millimetres
Ø25
Ø13
200
R6
60
R6
You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipment to an appropriate
waste disposal centre. The packaging material is recyclable.
Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service.
JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, PO20 2FT
rchase.
sis: