Canadian Electrical Code, Part 1.
of the National Electrical Code, and rules
12-010 (3), (4), and (5), and 12-020 of the
in accordance with Section 300.22 (C) and (D)
Fittings are suitable for use in Air Handling Spaces
Remove key
and re-secure
4.
the load.
4
File No. E228153
File No. E251132
Luminaire Fittings
Conduit & Cable Hardware
speaker, and attach the top to a dierent ceiling support
point of the building structur e, per Steps 1 & 2. After
4. Snap secondary support safety cable hook hanger
onto one of the side holes in the top bracket of the
height adjustment is nal, trim any unneeded extra cable
tail wires with trimmer suitable for 2 mm (0.077 in)
diameter stranded aircraft-type cable.
3.
Adjust
height.
SPEAKER
Suspension Systems:
INSTALLATION
INSTRUCTIONS
using
3
in the top bracket of the speaker. Adjust
to proper height by pulling cable through
3. With speaker supported, snap main
either end of Gripple.
support hook hanger onto the center hole
How to use Release Key to adjust height of speaker:
Detail
2. Pass tail end of cable through the
other channel of the Gripple (see
inset detail).
Use equipment only in accordance with manufacturer’s instructions. Do not alter or modify.
Do not use equipment if the equipment is not functioning correctly or if the equipment is defective
CAUTION: Installation must be done by qualied persons using safe rigging standards.
2.
Insert key into
small hole at
top of Gripple.
Push in 1/4” to
release the
cable.
Detail
load is supported.
1.
1. Thread Gripple onto cable (see inset
detail). Pass over ceiling anchor point
(as shown) or through other secure
anchor point of the building structure.
Installer is responsible for ensuring that
anchor point is secure to building
structure.
Make sure the

C60 INST INSTR 08/10
– Gripple hangers are designed for permanent
Not for re-use
installations, not for re-use.
tested and approved for seismic restraint applications, please
Lubricants – Do not apply oil or any other lubricant to any part
Not for seismic bracing – For Gripple products that have been
of the assembly.
refer to the Gripple Seismic product line.
Round duct/pipes – When wrapping around duct or other round
pipes, do not exceed an angle of 60 degrees between the top of
the pipe and the Gripple.
Environment – Standard Gripple hangers may be used only in
ventilated swimming pool arenas.
dry locations. Stainless steel Gripple hangers may be used in
certain indoor corrosive environments such as properly
Failure to observe these usage instructions may result in
product malfunction, resulting in property damage and bodily
injury. At time of shipment Gripple products are warranted to
conform to the manufacturer's published specications and to
be free from defects in material and workmanship. No other
warranty, whether expressed or implied, including any
warranty of merchantability or tness for purpose, whether
MANUFACTURER’S RECOMMENDATIONS
fore painting to protect from
See Other Side for Speaker Installation Instructions
– Gripple hangers are to be used to suspend
– Compliance with local codes, and where
expressed or implied, shall exist in connection with the sale or
use of any Gripple product.
this Gripple suspension product, please contact:
IL 60502 1-630-406-0600 www.gripple.com
Gripple Inc. 1611 Emily Lane Aurora,
For further technical assistance in the use of
8500 Balboa Blvd
Northridge, CA 91329
JBL Professional
USA
No lifting – Do not use for lifting, such as in a crane or pulley
loudspeaker is 45 kg (100 lbs).
Load – Do not exceed the Safe Working Load (SWL) of the
Gripple. The SWL of the Gripple product included with this
situation.
static loads only. Do not use to suspend moving services, or
services likely to be subject to movement.
No movement
No joining – Gripple hangers must not be spliced together
using a Gripple fastener, or any other joining device. A Gripple
hanger assembly must comprise one length of cable and one
Gripple fastener only. If a longer length is needed, do not
Limitations of use – All Gripple hangers, accessories, and
attempt to join two assemblies together.
other Gripple products must only be used for suspending items
applicable national codes, is the buyer and/or installers
recommended by the manufacturer.
Painting – If painting, ensure that a Gripple Décor Cover is
applied to the Gripple fastener be
the ingress of paint. Do not move the Gripple fastener on the
cable after painting.
responsibility.
Building codes