JBC Tools P405 User Manual

INSTRUCTION MANUAL
P405
Pedal
This manual corresponds to the following references:
P-405
Packing List
The following items are included:
Pedal ..............................................................1 unit Manual .................................................... 1 unit
Ref. 0028917
Connect the pedal to JBC station or peripherals. The connector is identified by the designation
“ P E D A L”.
Pedal
Ref. P-405
2
Pedal Compatibility
para manuales - color gris
P405 is compatible with JBC devices as shown in the table in the highlighted column.
P305* and P005* is also shown in the table below.
Marked with means pedal P405 cannot be connected directly to JBCs control unit. A module
must be used (See next pages “Pedal Set Up”).
Pedals
P405 P305* P005*
DIU
Control
Unit
DDU
DMU
HDU
JNAU
JTU
WSU
ALU
Station AL
Module
Preheater
Fume
Extractor
NAU
MSE
MVE
MNE
PHNK
PHSK
PHBK
PHXK
FAE1
FAE2
* not included, sold separately
3
Pedal Set Up for:
- DDU, HDU, NAU, JNAU, JTU, ALU (Control Units)
- PHNK, PHSK, PHBK, PHXK (Preheaters)
Note: Peripheral moduls - MSE, MVE or MNE - are needed to connect the pedal to DDU y HDU.
1. Enter the Peripherals Menu and select the port which you want to join to the pedal.
17:14
Peripherals Port 2-PA
Pedal PD_a
Module MSE
Select port
2. Select the pedal from the list.
17:14
Peripherals Port 2-PA
Pedal PD_a
Module MSE
Pedal
PD_a
PD_b
None
Note that your first
connection is denoted
as “a”, the second
being “b”, etc. (e.g.
PD_ a, PD_ b,...)
3. Set the pedal function according to your work needs:
Select how the pedal
acts: as Sleep,
Extractor (hibernation)
or as a module switch.
Select the activating
mode of the pedal
(pressed/released)
Peripherals Port 2-PA
Pedal PD_a
Function Extractor
Mode released
Minimum time 0 sec
Back
17:14
Set the duration
of the activation
time when pressing
the pedal once*.
For continuous
functioning keep the
pedal pressed.
*NB: The same can be applied inversely by continually pressing the pedal and releasing to activate.
4
Pedal Set Up for DMU (Control Unit)
para manuales - color gris
Note: Peripheral moduls - MSE, MVE or MNE - are needed to connect the pedal to DMU.
After connecting one of the mentioned moduls to the station a popup window opens.
1. To configure the module MSE/MVE/MNE press Setup in the popup window.
17:14
?
Peripherals
Port 1 2 3 4
MS a
PERIPHERAL
Peripheral 1 plugged:
Electric Suction Module
Setup
Postpone
2. Select the module from the list of peripheral connections. Remember your first connection is
denoted as “a”, the second being “b”, etc. (e.g. MS_a, MS_b,...). Do the same with the pedal (e.g.
PD_ a,...)
3. Select the port of the tool you want to link to the peripheral.
17:14
?
Peripherals
Port 1 2 3 4
MS a
PD a
4. Press Menu or Back to save changes.
Once set up, the module settings can be changed by entering the Peripherals Menu .
5
Pedal Set Up for FAE1, FAE2 (Fume Extractors)
1. Enter the Main Menu and select Port.
Main menuMain menu
1 Reset 2
Unit
3
Port
4 Filter set 5 Counters 6 Program version
2. At the Port Menu select Pedal.
1 Program Ctm - 100% 2
Delay to stop
3
Pedal
Exit
Select Port
PortPort
Select Pedal
BackBack
3. Set the pedal function according to your work needs:
PedalPedal
1 Activation One-touch 2 Mode Pressed
BackBack
Shows the activation mode.
Choose between One-
touch* and Continous*.
Select the activating mode of
the pedal. Choose between
Pressed and Released.
* One-touch activates the pedal funtion until pressed twice. Continous activates the pedal function
while pressing the pedal.
6
Example:
para manuales - color gris
Chip Compoments Rework Process using Tweezers and Pedal
The Pedal is frequently used to rework components with tweezers.
AN115 JBCs adjustable nano tweezers is the most effective tool for desoldering chip components but also it facilitates its rapid placement and soldering by using P405 pedal connected to JBC´s NAS station.
1
ROBOT
NAS
2-Tool Nano Rework Station
connect to the same port
AN115
Ajustable Nano Tweezers
P405
Pedal
Connections
Connect pedal P405 to the same port where AN115 nano tweezers are connected.
In the peripherals menu for the “Pedal Activation Mode” choose between “pressed” and “released”.
7
C115
C11
C105 /
C105 / C115
19:29
ºC
NT105
2
* “Press Mode” previously selected
3
4
DPM
Manual
Solder Paste
Dispenser
AN115
Ajustable Nano Twe eze rs
DS360
Micro Desoldering Iron
Desoldering*
Lift the tool from the holder, press and hold the pedal to activate the tool and desolder the component.
Once the pedal is released the tool enters in hibernation mode and cools down.
Pad Cleaning
Clean the pads with JBC´s desoldering tool DS360.
For this operation JBC´s desoldering station DSS is needed.
Solder Paste Dispensing
Apply the solder paste amount needed to solder the new chip component.
The use of JBC´s DPM solder paste dispenser is recommended.
8
5
para manuales - color gris
AN115
Ajustable Nano Twe eze rs
Placing
Do not press the pedal.
Use the tool to position the component on the previously tinned pad.
Note:
The inactive tool prevents the component from heating up prematurely.
6
AN115
Ajustable Nano Twe eze rs
Soldering
Once in position press and hold the pedal to activate the tool and perform the soldering.
9
Notes
10
Notes
para manuales - color gris
11
para manuales - color gris
Specifications
P405
Pedal
Ref. P-405
- Cable length: 1.9 m / 74.80 in
- Total Net weight: 232 g / 0.51 lb
- Total Package Dimension / Weigt: 155 x 85 x 55 mm / 255 g
(L x W x H) 6.10 x 3.35 x 2.17 in / 0.56 lb
Complies with CE standards
ESD safe
Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warrant y does not cover product wear or misuse. In order for the warrant y to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and retur ned to an authorized recycling facility.
0028917-150622