jbc FAE2-5A Instruction Manual

INSTRUCTION MANUAL
Fume Extractor
Ref. FAE2-5A
www.jbctools.com
INSTRUCTION MANUAL
Ref. FA E 2-10 0 *Already assembled
Packing List
The following items should be included:
Fume Extractor ......................................... 1 unit
Ref. FAE2-5A
Cleaning stick ............................................ 1 unit
Ref. 0004009
Manual ........................................................... 1 unit
Ref. 0018826
Power cable ................................................ 1 unit
Ref. 0009417 (100V / 120V) 0009401 (230V)
RJ12 direct cable .................................... 2 units
Ref. 0 019751
2
Fume Extractor
Ref. FAE2-5A
www.jbctools.com
Features
Aspiration tube for up to 4 stands (2 work
intakes configuration) or for 1 workbench
(4 work intakes configuration).
Aspiration
tubes for
workbenchs
Wheels and brake system to move around easily
Filter saturation indicator
Connections ports
Quick release lever for filter change
Power socket
Main switch
Process screen
Aspiration tube for up to 4 stands (2 work intakes configuration) or for 1 workbench (4 work intakes configuration).
www.jbctools.com
3
Features
Pre-filter
Re f. FA E2-110
Compact filter + Pre-filter
Ref. FA E 2-10 0
Important:
Before using, unseal the filter and remove the bottom protection of the compact filter.
4
Visit www.jbctools.com for further details.
Fume Extractor
Ref. FAE2-5A
Accessories for stand aspiration (up to 4 stands)
Ref. FAE040
To be assembled on your workbench with the included clamp
Ref. FAE030
To be assembled directly on your workbench (hole drilling required)
Stand Aspiration Ducts
Ref. FAE050
For modular stands (From SD versions onwards)
Ref. FAE060
For compact stations (From B versions onwards)
Flexible arms Ø50
Ref. FAE070
Lenght: 1 m (39.37 in)
To be assembled on your workbench with
the included clamp
Ref. FAE020
To be assembled directly
on your workbench
(hole drilling required)
Flexible Hoses Ø50
Ref. FAE010
Lenght: 1,5 m
(59.05 in)
Connect the Fume
Extractor to the flexible
arm or to the accessory
for stand aspiration
Assembly for 2 work intakes configuration (default configuration)
For a basic working system you need:
www.jbctools.com
5
Flexible Hoses Ø50
Ref. FAE010
Lenght: 1,5 m
(59.05 in)
Connect the Fume
Extractor to the flexible arm
Visit www.jbctools.com for further details.
Fume Extractor
Ref. FAE2-5A
Assembly for 4 work intakes configuration (optional configuration)
In this configuration aspiration at stand is not available, aspiration flow is set High. Note that in this configuration, suction force per intake is decreased when compared to 2 work intakes configuration. See details on page 16. For a basic working system you need:
Flexible arms Ø50
Ref. FAE070
Lenght: 1 m (39.37 in)
To be assembled on your workbench with
the included clamp
Ref. FAE020
To be assembled directly
on your workbench
(hole drilling required)
6
Communication ports
RJ12 connections take precedence over USB connections. The fume extractor will only attend RJ12 port.
Connection with Excellence range
Connect up to 2 stations directly to the fume extractor using RJ12 ports.
For a correct operation always update the soldering stations with the latest software version available. The minimum required version is number 8886160 for DDE, HDE & NAE stations and number 8886162 for DME stations.
For 2 work intakes configuration, when two stations are connected to the fume extractor, each station controls the extraction port to which it is connected. Every tool connected to the soldering station need to be asigned to an available fume extraction port through the Peripherals menu of the station.
For 4 work intakes configuration, when two stations are connected to the fume extractor, the station connected to port1 controls extraction ports 1 and 2, whereas station connected to port2 control extraction ports 3 and 4. Every tool connected to the soldering station need to be asigned to an available fume extraction port through the Peripherals menu of the station.
station 1 station 2
www.jbctools.com
7
Aspiration ports control
For 2 work intakes configuration:
If only 1 station is connected to Port1, the station will detect the 2 work intakes identified as FAE_a (work1) and FAE_b (work2).
For 4 work intakes configuration:
If only 1 station is connected to Port1, the station will detect the 4 work intakes identified as FAE_a (work1), FAE_b (work2), FAE_c (work3) and FAE_d (work4).
For 2 work intakes configuration:
If 1 station is connected to Port2, the station will only detect the work2 intake identified as FAE_a.
For 4 work intakes configuration:
If 1 station is connected to Port2, the station will detect the 2 last work intakes identified as FAE_a (work3) and FAE_b (work4).
The pedal connection takes precendence over the RJ12 connection, the equipment will only attend the Pedal port.
For 2 work intakes configuration:
When 2 stations are connected to Port1 and Port2, work intakes 1 and 2 are both detected as FAE_a in the Peripherals menu of soldering stations.
For 4 work intakes configuration:
When 2 stations are connected to Port1 and Port2, work intakes 1 and 3 are detected as FAE_a and work intakes 2 and 4 as FAE_b in the Peripherals menu of soldering stations.
8