Packing List
The following items should be included:
Manual ........................................................... 1 unit
Ref. 0020107
Compact Filter
Ref. FAE2-100
Compact Filter ........................................... 1 unit
Ref. FA E 2-10 0
(Includes pre filter and certificate)
2
www.jbctools.com

Features
Pre filter
Re f. FA E 2-110
Fume Extractor
Ref. FAE2-5A
Compact filter
+ Pre filter
Ref. FA E 2-10 0
Important:
Before using, unseal
the filter and remove
the bottom protection
of the compact filter.

- The unit notifies through both the display
and the LED when filters need maintenance.
- To replace the filters, first turn the fume
extractor off. Then remove the cover by
opening the side closures of the casing.
- If once the pre-filter has been changed the
saturation indicator is on, it means that the
compact filter is already saturated and must
be replaced too.
- The duration of the compact filter is 1 year
maximum once its packaging is opened.
- Once the compact filter has been replaced,
the filter counter must be reset.
(Main Menu > Filter > Reset)
- If the display shows an error message when
the equipment is switched on, it is probable
that the cover and casing connectors are
dirty and making false contact between
them. Remove the cover again and clean
both connectors.
Replacement
Read safety guidelines to do the equipment maintenance securely.
4

4 Filter
5 Counters
6 Program version
Main menu
Exit
1 Reset
2
Unit
3
Port
STOP # 1
Useful filter life is worn out.
Replace it and execute reset
function in the filter menu.
STOP # 3
Filter not detected. Place
a filter in order to use the
fume extractor.
STOP # 2
Filter obstructed. Replace
the pre-filter, if the error
remains, replace the
HEPA+carbon filter set.
WARNING # 1
Useful filter life is about to
wear out. In X days the filter
life is going to finish.
WARNING # 2
Filter is about to obstruct.
Filter
1 Status 80%
2 Reset
Back
Filter
1 Status 80%
2 Reset
Back
Control Process
Filter Menu
Warning & Errors
Shows % of remaining life of
HEPA + carbon filter set. It is also
displayed on the main screen.
Perform this action when changing
the HEPA + carbon set filter. The
filter life counter doesn’t start until
the filter is detected for the first time.
The unit notifies when filters need maintenance.
The unit stops working when filters have to be replaced.

Safety
- The equipment is only designed to filtrate the fumes generated by soldering.
- Do not use the units for the filtration of combustible, explosive or corrosive gasses.
Incorrect use may cause fire.
- Maintenance must not be carried out by children unless supervised.
- Keep your workplace clean and tidy. Wear appropriate protective mask, glasses and gloves when
handling dirt filter or pre-filter.
- Saturated filters can not be cleaned and reused.
- Avoid blowing the filter or the dirty parts of the equipment, if necessary it is advisable to vacuum.
- Avoid losing particles in the filter during handling it.
- Treat the saturated filters as waste depending on the filtered contaminant and the applicable
standars in each country.
European Waste Catalog classification:
15 02: Absorbents, filter materials, wiping cloths and protective clothing.
15 02 02: Absorbents, filter materials (including oil filters not otherwise specified, wiping cloths,
protective clothing contaminated by dangerous substances.
15 02 03: Absorbents, filter materials, wiping cloths and protective clothing other than those
mentioned in 15 02 02.
- In case of not complying with the filter change recommendations, the maximum particle and gas
concentrations established in each country could be exceeded.
It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
6

This product should not be thrown in the garbage.
In accordance with the European directive 2002/96/EC, electronic equipment at the end of their life
must be collected and returned to an authorized recycling facility.
Manual in other languages available on our website
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Register your warranty within 30 days of purchase
in www.jbctools.com/productregistration
0020107-0618
Specifications
- Net Weight: 4,5 kg (9.9 lb)
- Dimensions: 450 x 205 x 185 mm (17.72 x 8.07 x 7.28 in)
- Pre-filter: Medium dust filter M5 (EN 779)
- Compact Filters: H13 particle filter (EN 1822)
Activated carbon filter
Complies with CE standards.
ESD protected.