WORK
220
time
SLEEP
220
time
HIBERNATION
room
temperature
2
DI/1 TOOL CONTROL UNIT
+
+
DESOLDERING PUMP
MS-A
DESOLDERING STAND
DR-SA
The JBC stations intelligently manages the tool temperature:
Work status: When the tool is out of the stand, the working temperature is 350º C.
Sleep status: When the tool is on the stand, the temperature is being lowered to 220º C.
Hibernation status: During larger periods of inactivity i.e 30 minutes, the tool’s power is being cut off
and it cools down to room temperature.
The advantages of this heat management is the lifespan increase which ensure low cost of ownership.
CONTROL UNIT
DI-2A
Connectable tools: T210, T245, PA, HT, AP, DR and DS.
Connectable modules: MS, MV and MN.
CONTAINS
INSTALLATION / I.E.CONNEXION
HEAT MANAGEMENT
Electric intel
DI
1 TOOL
CONTROL UNIT

ORIGINAL PIN: 0105
Press during 2 seconds
to enter SETTINGS
SELECT
Main me nu
Stati on set ti ng s
Count er s
Tool se tt in gs
1 Reset settings
2
Station settings
3
Tool settings
4
Counters
1
Language English
2
Temp unit Celsius
3
Maximum temp 4000C
4
Minimum temp 2000C
1
Plugged hours 0
2
Working hours 0
3
Sleep hours 0
4
Hibernation hours 0
1
Fix one temp -----
2
Temp levels set OFF
3
Sleep delay 0 min
5
Program version
5
Nitrogen mode OFF
6
Help text OFF
7
Beep ON
8
Change PIN
5
No tool hours 0
6 Sleep cycles
0
7 Desold cycles
0
4
Sleep temp 2200C
5
Hibernation delay 30 min
6
Temp adjust O OC
Tool DR
Tool DR
Exit
Back
Back
Back
DR
Working temp 3500C
Power 10%
350 0C
3
WORKING
SETTINGS
Selected temperature
% Instant power supplied to the tool
Working tool model
Status
Decreas & move down
Selection
Increase & move up

ENGLISH / WARRANTY
The JBC 2 years warranty, guarantees this equipment against all
manufacturing defects, covering the replacement of defective parts
and all necessary labour.
Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned,
postage paid, to the dealer where it was purchased enclosing this,
fully filled in, sheet.
MORE INFORMATION
www.jbctools.com
SERIAL N`
STAMP OF DEALER
DATE OF PURCHASE
0008528/0409
MANUFACTURED BY
JBC Industrias, S.A.
Ramón y Cajal, 3
08750 MOLINS DE REI
BARCELONA - SPAIN
Tel.: +34 93 325 32 00
Fax: +34 93 680 49 70
www.jbctools.com
info@jbctools.com
THECNICAL SPECIFICATIONS
- Temperature selection from 90 to 450°C (±5%).
- Power: 75W.
- Safety transformer, mains separator and double isolation, with integrated temperature protection fuse.
- DI-2A 230V control unit. Input: 230V 50Hz. Output: 24V.
- DI-1A 120V control unit. Input: 100V 60Hz. Output: 24V.
- Total weight of unit: 2 Kg.
- Complies with CE standards on electrical safety, electromagnetic compatibility and ESD protected housing
“skin effect”.
- RoHS compliant.
- Equipotential connector and the tool tip are connected to station mains ground supply for ESD protection.
This product should be
thrown in the garbage.