jbc CLMU-PA, CLMU-A8, CLMU-A7, CLMU-P1, CLMU-P7 Instruction Manual

Page 1
INSTRUCTION MANUAL
Universal Tip Cleaner
Non-Metal Brushes
Ref. CLMU-PA
www.jbctools.com
Page 2
222
Packing List
The following items should be included:
EU
Ref. CLMU-PA
Universal Tip Cleaner
Non-Metal Brushes
Universal Tip Cleaner ................................. 1 unit
Non-Metal Brushes
Ref. CLMU-PA
CLMU-PA Non-Metal Brushes ............. 1 unit
Ref. CLMU-P1 Brushes already installed inside the cleaner
AC Adapter .................................................... 1 unit
Ref. 0022529
Manual ............................................................ 1 unit
Ref. 0022344
US
www.jbctools.com
Page 3
333
Features
Locking tab
Splashguard
Window
Feet for vertical
access
Power cord socket
ESD safe connector
USB-B connector
Sensors window
Switch panel
www.jbctools.com
Page 4
444
Operation
For best cleaning results, we recommend placing the tip between the two brushes for just 1 second. Longer exposure time would lead to dewetting of tip surface causing oxidation.
If excessive pressure is applied with the tool against any of the brushes, the cleaner stops automatically in order to protect the motors. Putting the tool out of the sensor detection area automatically reactivates the cleaner.
Sensor
mode
Continuous
mode
On / Off
The CLMU-PA is automatically switched off if the splashguard is opened during operation.
Led status
- White: Off
- Blue: Standby
- Green: Brushes activated
- Blinking Red: Brushes jammed
Page 5
555
Brush replacement
1. Pull the locking tab to open the
splashguard.
2. Pull the used up brushes out of the cleaner by pressing its two opposite buttons. To replace the brushes just push them without pressing the buttons.
Remove the solder collection tray for disposal of solder waste. The tray can be removed without disassemble the brushes.
Collection tray
www.jbctools.com
Page 6
666
Brushes range
CLMU-A8 CLMU-A7 CLMU-P1 CLMU-P7
Metal Metal Non-metal Non-metal
Cleaning Intensive Intensive Gentle Gentle
Max. time use 10 s 10 s 5 s 5 s
Recommended
time use
1-2 s 1-2 s 1-2 s 1-2 s
Life cycle* Long Long Extended Extended
Core** Black Blue Black Blue
Only use the non-metal Brushes when they are turning. Incorrect use will damage them.
* When used properly, the non-metal Brushes will have a longer life than the metal ones. ** The blue core is used to distinguish it from the black core when doing lead-free and leaded soldering.
When changing Brushes, see the table below for the different brush types.
CLMU-A Metal Brushes
(Black core) Ref. CLMU-A8
CLMU-A Metal Brushes
(Blue core) Ref. CLMU-A7
CLMU-A Non-Metal Brushes
(Black core) Ref. CLMU-P1
CLMU-A Non-Metal Brushes
(Blue core) Ref. CLMU-P7
Core
Material
Page 7
777
Maintenance
Before carrying out maintenance or storage, always unplug the equipment from the mains.
- Use a damp cloth to clean the splashguard and the inside.
- Check periodically that the sensors window is clean. Use a cotton bud with alcohol to clean it.
- Maintain the brushes and the solder collection tray clean.
- Replace any defective or damaged piece. Use original JBC spare parts only.
- Repairs should be performed only by a JBC authorized technical service.
Sensors window
www.jbctools.com
Page 8
JBC
Manager
888
USB Connector
Download the latest software from our website to improve your CLMU-PA.
JBC Updater
www.jbctools.com/software.html Update the cleaner software via USB connection:
USB AB Cable
JBC
Updater
JBC Manager
www.jbctools.com/manager.html Manage and monitor as many stations as your PC can handle by using the JBC Manager. You can export data to another PC.
Register Settings
Create graphs of the soldering process in real time with power and temperature data.
Manager Settings
Change settings for a group of JBC stations at the same time.
any JBC
station
USB
Hub
USB AB Cable
Page 9
9
It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
99
- Do not use the appliance for any purpose other than tip cleaning. It is not a tool stand.
- The AC Adapter power supply must be plugged into approved bases.
- Do not leave the appliance unattended when it is running.
- Remove power cord by holding the plug, not the wire.
- Avoid contact with moving parts.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid harm.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.
- Utmost care must be taken with liquid tin waste which can cause burns.
- Be careful with the fumes produced when soldering.
Safety
www.jbctools.com
Page 10
101010
Notes
Page 11
111111
www.jbctools.com
Page 12
Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear due to use or mis-use. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
Manual in other languages available on our website
This product should not be thrown in the garbage. In accordance with the European directive 2002/96/EC, electronic equipment at the end of their life must be collected and returned to an authorized recycling facility.
- AC Adapter: Input: 100-240V, 50/60Hz Output: DC 24V, 2A
- Brush diameter: 50 mm
- Weight: 2.1 Kg (4.63 lb)
- Dimensions: 128 x 131 x 137 mm
- Ambient operating temp.: 10 to 40 ºC / 50 to 104 ºF
- ESD safe connector
Complies with CE standards. ESD protected housing “skin effect”.
0022344-0219
Specifications
www.jbctools.comwww.jbctools.com